• Title/Summary/Keyword: Dye Test

Search Result 318, Processing Time 0.027 seconds

A Study on the Manufacture of Optical Filters for PDP Panel in Conductive Types (PDP 패널용 전도막 광학 필터 제조에 관한 연구)

  • Kim, Tae-Hoon;Kang, Bong-Gu;Lee, Tae-Hoon;Son, Se-Mo
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.26 no.2
    • /
    • pp.31-43
    • /
    • 2008
  • The functional dyes, which has various optical characteristics that can be applicable to field of electronic, photo electronic, such as sensor or electrode, were synthesized. Physical property and optical stability was studied with preparation of conductive type film as a kind of optical filter of plasma display panel, by adapting neon cut off dye, which can selectively absorbing between 580 and 610nm wavelength. The filter was prepared with PSA resin, which has functional group of - COOH and - OH, as binder. And the characters such as spectroscopy, heat-proof / wet-proof, thermal stability and commerciality, which must be held by functional dyes, were examined. Conductive type film is the kind of film includes only neon cut off dyes. For the neon cut off dyes, cyanine dyes can be applied. And it is observed that spectrum of before and after the durability test are not changed due to stability of dyes, as the result of coating on the mesh film with PSA binder.

  • PDF

Evaluation of Bovine Amniotic Membrane for the Treatment of Superficial Canine Corneal Ulcer (개의 표재성 각막 궤양에서 소의 양막을 이용한 치료에 대한 평가)

  • Choi, Young-Min;Kim, Joon-Young;Park, Jong-Im;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.358-366
    • /
    • 2007
  • This study was performed to investigate the application of bovine amniotic membrane for canine corneal ulcer and to compare bovine amniotic membrane flap to nictitating membrane flap. Corneas were treated with 8.0mm trephine and 100% ethanol was applied and corneal epithelium was removed. This experiment was divided into three groups; control group, nictitating membrane flap group and amniotic membrane + nictitating membrane flap group. To compare corneal healing, fluorescein dye test, histopathological examination and TUNEL assay were performed. The healing size of the corneal epithelium in was largest among groups and it was significantly different with the other groups (P<0.05). Also, inflammatory cell deposits and keratocyte apoptosis in amniotic membrane flap group were smallest, but the width of the corneal epithelium was thickest among groups. Therefore, we tentatively predicted that the amniotic membrane flap would be an alternative effective method for the treatment of superficial canine corneal ulcer.

MARGINAL LEAKAGE OF CLASS 2 GLASS-IONOMER CEMENT RESTORATIONS NOT INVOLVING OCCLUSAL SURFACE (교합면을 포함하지 않는 2급 글래스 아이오노머 시멘트 수복물의 변연누출)

  • Lee, Young-Ran;Hur, Bock;Lee, Hee-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.288-295
    • /
    • 1998
  • The microleakage of direct-access Class 2 restorations was evaluated. Cavities were prepared at mesial and distal proximal enamel surfaces of 20 extracted human molars through buccal window. Prepared cavities were filled with Ketac-Fil, Ketac-Silver, and Fuji II LC, following manufacturer's instructions. 4 specimens of each restorations were made through sectioning 1/4 of bucco-lingual length mesio-distally after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and imerging 0.5% basic-fuchsin dye solution. Leakage at both occlusal and gingival margin of each specimen was scored 0 to 3 with stereomicroscope. The results were as follows: 1. At occlusal margin, leakage in Ketac-Fil group was more than Ketac-Silver and Fuji II LC group (ANOVA p<0.05) and there was no significant difference between Ketac-Silver and Fuji II LC group(p>0.05), and at gingival margin, there was no significant difference amang materials (p>0.05). 2. Occlusal margin leaked more than gingival margin in Ketac-Silver and Fuji II LC group (t-test p<0.05). 3. Leakage was different according to bucco-lingual location in Ketac-Fil and Fuji II LC group, and lingaul specimen exhibited more leakage(ANOVA p<0.05).

  • PDF

Microwave Assisted Synthesis of Graphene-Bi2MoO6 Nanocomposite as Sono-Photocatalyst

  • Tang, Jia-Yao;Zhu, Lei;Fan, Jia-Yi;Sun, Chen;Oh, Won-Chun
    • Korean Journal of Materials Research
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • In this investigation, Bi2MoO6 deposited graphene nanocomposite (BMG) was synthesized using a simple microwave assisted hydrothermal synthesis method. The synthesized BMG nanocomposite was characterized by X-ray diffraction, transmission electron microscopy, scanning electron microscopy with energy dispersive X-ray analysis, and photocurrent analysis. The study revealed that the catalysts prepared have high crystalline nature, enhanced light responsive property, high catalytic activity, and good stability. XRD results of BMG composite exhibit a koechlinite phase of Bi2MoO6. The surface property is shown by SEM and TEM, which confirmed a homogenous composition in the bulk particles of Bi2MoO6 and nanosheets of graphene. The catalytic behavior was investigated by the decomposition of Rhodamine B as a standard dye. The results exhibit excellent yields of product derivatives at mild conditions under ultrasonic/visible light-medium. Approximately 1.6-times-enhanced sono-photocatalytic activity was observed by introduction of Bi2MoO6 on graphene nanosheet compared with control sample P25 during 50 min test.

The effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement

  • Tuncdemir, Ali Riza;Yildirim, Cihan;Ozcan, Erhan;Polat, Serdar
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.457-463
    • /
    • 2013
  • PURPOSE. The purpose of this study was to compare the effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement. MATERIALS AND METHODS. Fifty-five incisors extracted due to periodontal problems were used. All teeth were instrumented using a set of rotary root canal instruments. The post spaces were enlarged for a No.14 (diameter, 1.4 mm) Snowlight (Abrasive technology, OH, USA) glass fiber reinforced composite post with matching drill. The teeth were randomly divided into 5 experimental groups of 11 teeth each. The post spaces were treated with the followings: Group 1: 5 mL 0.9% physiological saline; Group 2: 5 mL 5.25% sodium hypochlorite; Group 3: 5 mL 17% ethylene diamine tetra acetic acid (EDTA), Group 4: 37% orthophosphoric acid and Group 5: Photodynamic diode laser irradiation for 1 minute after application of light-active dye solution. Snowlight posts were luted with self-adhesive resin cement. Each root was sectioned perpendicular to its long axis to create 1 mm thick specimens. The push-out bond strength test method was used to measure bond strength. One tooth from each group was processed for scanning electron microscopic analysis. RESULTS. Bond strength values were as follow: Group 1 = 4.15 MPa; Group 2 = 3.00 MPa; Group 3 = 4.45 MPa; Group 4 = 6.96 MPa; and Group 5 = 8.93 MPa. These values were analysed using one-way ANOVA and Tukey honestly significant difference test (P<.05). Significantly higher bond strength values were obtained with the diode laser and orthophosphoric acid (P<.05). There were no differences found between the other groups (P> .05). CONCLUSION. Orthophosphoric acid and EDTA were more effective methods for removing the smear layer than the diode laser. However, the diode laser and orthophosphoric acid were more effective at the cement dentin interface than the EDTA, Therefore, modifying the smear layer may be more effective when a self-adhesive system is used.

Epidural Adhesiolysis in Low Back Pain (요통환자에서 경막외 유착 용해술에 의한 제통효과)

  • Lee, Sang-Chul;Oh, Wan-Soo;Kim, Jin-Kyoung;Roh, Chang-Joon;Son, Jong-Chan
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.214-219
    • /
    • 1997
  • Background: Epidural neural blockade with local anesthetics combined with steroids has been in clinical trials for patients with low back pain. But pain treatment of low back pain remains somewhat problematic. Many patients with low back pain have epidural fibrosis and adhesions proved with magnetic resonance imaging(MRI) examination. These findings might play an important role in the origin of back pain. Present study was aims to investigate the effect of epidural adhesiolysis in patients with low back pain. Methods: We investigated 76 patients suspected with epidural fibrosis and adhesion was suspected. Nerve pathology was demonstrated and epidural fibrosis suspected or proved with MRI examination. 17G needle specially designed by Racz was inserted at sacral hiatus and catheter was inserted untill its tip was located at lesion site under fluoroscopic guidance. Injection of contrast dye was achieved and prospected spread of agents. Injection of 0.25% bupivacaine, triamcinolone, and 10% hypertonic saline via catheter were carried out daily for 3 days. Evaluation included assessment of pain relief (Numerical Rating Scale; NRS) post-epidural adhesiolysis 3 days, 1 week, and 3 months. We also looked for complication of epidural adhesiolysis. Results: Statistical analysis(Friedman nonparametric repeated measures test and Dune's multiple comparison test) demonstrated NRS was significantly less during 3 months after epidural adhesiolysis(P<0.05). Especially, there is a extremely significance in post-epidural adhesiolysis 3 days (P<0.001). Only four patients reported any complications the most common symptom among three persistent headache but disappeared after a few months without residual sequelae. Conclusion: We conclude epidural adhesiolysis is a safe and effective method of pain therapy for low back pain with proven lumbo-sacral fibrosis and adhesion. A direct visualization by epiduroscopy may be more useful to the resulting functional changes after epidural adhesiolysis.

  • PDF

EFFECT OF WETNESS ON THE ENAMEL BONDING (법랑질 접착에 대한 습윤 효과)

  • Ko, Keun-Ho;Cho, Young-Gon;Jin, Cheul-Hee;Yoo, Sang-Hoon;Kim, Jong-Uk;Park, Byung-Cheul;Ki, Young-Jae;Choi, Hee-Young;Kim, Jong-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.205-211
    • /
    • 2004
  • This study evaluated the microleakage and interfacial gap between enamel and composite resin under the dry and wet condition of the enamel surface. V shaped class 5 cavities were prepared on the occlusal portion of extracted human molars. Samples were divided into three groups:D group (air dry for 10-15s), BD group (blot dry with moist cotton pellet), and DR group (air dry for 10-15s and rewet with Aqua-Prep F for 20s), Cavities were filled using Aelitefil composite resin after applied One-Step. Microleakage was tested by 2% methylene blue dye solution and the data were statistically analysed by Kruskal-Wallis test and Mann-Whitney test. Also Enamel-resin interface was observed under SEM. Group BD showed statistically lower microleakage than group D (p < 0.05). but there was no statistically significant difference between group BD and DR (p > 0.05). At the enamel-resin interface, group D showed the gap of $2{\;}{\mu}m$ thickness, but group BD and DR showed close adaptation. In conclusion, the use of blot dry and rewetting agent (Aqua-Prep F) resulted in decreased microleakage and improved adhesion between enamel and resin when using One-Step.

Post space preparation timing of root canals sealed with AH Plus sealer

  • Kim, Hae-Ri;Kim, Young Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.27-33
    • /
    • 2017
  • Objectives: To determine the optimal timing for post space preparation of root canals sealed with epoxy resin-based AH Plus sealer in terms of its polymerization and influence on apical leakage. Materials and Methods: The epoxy polymerization of AH Plus (Dentsply DeTrey) as a function of time after mixing (8, 24, and 72 hours, and 1 week) was evaluated using Fourier transform infrared (FTIR) spectroscopy and microhardness measurements. The change in the glass transition temperature ($T_g$) of the material with time was also investigated using differential scanning calorimetry (DSC). Fifty extracted human single-rooted premolars were filled with gutta-percha and AH Plus, and randomly separated into five groups (n = 10) based on post space preparation timing (immediately after root canal obturation and 8, 24, and 72 hours, and 1 week after root canal obturation). The extent of apical leakage (mm) of the five groups was compared using a dye leakage test. Each dataset was statistically analyzed by one-way analysis of variance and Tukey's post hoc test (${\alpha}=0.05$). Results: Continuous epoxy polymerization of the material with time was observed. Although the $T_g$ values of the material gradually increased with time, the specimens presented no clear $T_g$ value at 1 week after mixing. When the post space was prepared 1 week after root canal obturation, the leakage was significantly higher than in the other groups (p < 0.05), among which there was no significant difference in leakage. Conclusions: Poor apical seal was detected when post space preparation was delayed until 1 week after root canal obturation.

Studies on the Rapid Discrimination of Yellow Pigments Colored on Yellow Croakers and Natural Yellow Pigment of Croakers (참조기의 천연색소와 인위적으로 착색된 황색색소류 판별법에 관한 연구)

  • Kim, Hee-Yun;Hong, Jin-Hwan;Kim, Dong-Sul;Han, Sang-Bae;Lee, Eun-Ju;Lee, Jeung-Seung;Kang, Kil-Jin;Chung, Hyung-Wook;Song, Kyung-Hee;Park, Hye-Kyung;Park, Jong-Seok;Kwon, Yong-Kwan;Chin, Myung-Shik;Park, Hee-Ok;Oh, Sae-Hwa;Shin, Il-Shik;Lee, Chang-Kook;Park, Hee-Yul;Ha, Sang-Chul;Jo, Jae-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.977-983
    • /
    • 2002
  • This study was performed to establish the precise and rapid method to distinguish croakers through the pigment analysis of colored imported white croakers for adultration. We surveyed the coloring behaviors, extraction test by water and organic solvent and using pigments such as targeting, curcumine, and azo dye products. The pigment of yellow croaker is not stained on wet cloth or tissue which is rubbed on epidermis of yellow croaker and was not eluted in water extraction test, while adulterated pigments were easily extracted by water and acetone, but edible diluted yellow, Yellow No. 4 and Yellow No. 5 were not extracted. Reactive pigment was detected easily by extraction with water and dispersed pigment was also detected by extraction test. As a result of discoloring characteristics of carotene having similar structure to yellow croaker and azo dye by oxidation and reduction, azo dyes were not discolored by oxidation with sodium percarbonate or peracetic acid but that were discolored by oxidation with Fenton reagent after 1hr and by hypochlorite promptly. On the other hand, carotenes were not discolored by sodium precarbonate and Fenton reagent but discolored by sodium hypochlorite after 2 hr and by peracetic acid promptly. Azo dyes were discolored by reduction with sodium hydrosulfite and sodium carbonate but carotenes were not discolored by these reagents. This discoloring test was applicable to detect adulterated pigments and other marine product.

Freshness Monitoring of Raw Salmon Filet Using a Colorimetric Sensor that is Sensitive to Volatile Nitrogen Compounds (휘발성 질소화합물 감응형 색변환 센서를 활용한 연어 신선도 모니터링)

  • Kim, Jae Man;Lee, Hyeonji;Hyun, Jung-Ho;Park, Joon-Shik;Kim, Yong Shin
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.93-99
    • /
    • 2020
  • A colorimetric paper sensor was used to detect volatile nitrogen-containing compounds emitted from spoiled salmon filets to determine their freshness. The sensing mechanism was based on acid-base reactions between acidic pH-indicating dyes and basic volatile ammonia and amines. A sensing layer was simply fabricated by drop-casting a dye solution of bromocresol green (BCG) on a polyvinylidene fluoride substrate, and its color-change response was enhanced by optimizing the amounts of additive chemicals, such as polyethylene glycol, p-toluene sulfonic acid, and graphene oxide in the dye solution. To avoid the adverse effects of water vapor, both faces of the sensing layer were enclosed by using a polyethylene terephthalate film and a gas-permeable microporous polytetrafluoroethylene sheet, respectively. When exposed to basic gas analytes, the paper-like sensor distinctly exhibited a color change from initially yellow, then to green, and finally to blue due to the deprotonation of BCG via the Brønsted acid-base reaction. The use of ammonia analyte as a test gas confirmed that the sensing performance of the optimized sensor was reversible and excellent (detection time of < 15 min, sensitive naked-eye detection at 0.25 ppm, good selectivity to common volatile organic gases, and good stability against thermal stress). Finally, the coloration intensity of the sensor was quantified as a function of the storage time of the salmon filet at 28℃ to evaluate its usefulness in monitoring of the food freshness with the measurement of the total viable count (TVC) of microorganisms in the food. The TVC value increased from 3.2 × 105 to 3.1 × 109 cfu/g in 28 h and then became stable, whereas the sensor response abruptly changed in the first 8 h and slightly increased thereafter. This result suggests that the colorimetric response could be used as an indicator for evaluating the degree of decay of salmon induced by microorganisms.