• Title/Summary/Keyword: Duty factor

Search Result 363, Processing Time 0.023 seconds

A Study on Characteristic Analysis of High Frequency Generating Circuit Integrated Chopper-Inverter with High Power-Factor (고역률 초퍼-인버터 일체형 고주파 발생회로의 특성해석에 관한 연구)

  • Won Jae-Sun;Park Jae-Wook;Nam Seung-Sik;Lee Bong-Seob;Seok Jul-Ki;Kim Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.10
    • /
    • pp.610-617
    • /
    • 2004
  • This paper presents a novel high frequency generating circuit integrated chopper-inverter using ZVS with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant inverter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications. fluorescent lamp and DC-DC converter etc.

Design of Interleaved Boost Power Factor Preregulator (Interleaved 승압형 역률 전치보상 컨버터의 설계)

  • Heo, T.W.;Noh, T.G.;Jung, J.R.;Ahn, I.M.;Son, Y.D.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1123-1125
    • /
    • 2002
  • In this paper, interleaved boost converter is applied as a pre-regulator in switch mode power supply. Interleaved Boost Power Factor Preregulator (IBPFP) can reduce input current ripple as a simple voltage control loop only without inner current loop, because input current is divided each 50% by two switching devices. IBPFP can be classified as three cases from duty ratio condition in continuous current mode and be carried out state space averaging small signal modeling. According to modeling, the PID controller is applied and voltage control loop is constructed for suitable design condition. From frequency domain analysis, it is verified that control system is satisfied with design condition of switch mode power supply.

  • PDF

Performance Improvement of Power Control System for Driving MGT

  • Lee Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.744-749
    • /
    • 2005
  • This paper describes the performance improvement of power control system of magnetron (MGT) for microwave oven. The MGT is used extensively in household microwave oven and industrial microwave heating devices, and is operated by 3.0[kV] $\∼$5.0[kV] dc high voltage. The proposed power supply is consisted of a bridge rectifier, step-up converter(SUC) and its controller, half bridge inverter(HBI) and its controller, and full wave double voltage rectifier(DVR). In the proposed system, a good power factor can be obtained by the SUC' switching method that the inductor current waveforms follows that of the rectified voltage, and a line input power can be controlled to a range of 17.5[$\%$] by duty ratio (DR) adjustment of the HBI.

Experimental Investigation and Performance Test of Heavy Duty Torque Converter (중부하 토크 컨버터의 실험적 성능분석)

  • Lee, Hae-Jong;kim, Se-Hyun;Lee, Chung-Seub;Lee, Sang-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.690-695
    • /
    • 2004
  • The present study is an investigation on the characteristics of heavy load toque converter by experimental process. To get the dynamic performance, the dynamometer was used with a parameters of speed, torque, oil pressure and oil flux, etc. The torque converter was tested for various input speed, output oil pressure and input oil flow rate. All experiments were investigated in case that the speed ratio is increased. The torque ratio and capacity factor was in inverse proportion to speed. Engine revolution had a more effects at region of low speed ratio. But, the opposite phenomena were represented increase of efficiency. In result of this experiments, the characteristics of torque converter were not influenced by oil pressure and oil flux.

  • PDF

The Position Error Reduction of LPM Using PWM (펄스폭 변조법을 이용한 LPM 위치오차의 저감)

  • Park Kyung-Bin;Bae Dong-Kwan;Kim Kwang-Heon;Park Hyun-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.190-193
    • /
    • 2001
  • This paper describes the reduction of vibration and position error of Linear Pulse Motor(LPM) with the control method of PWM duty ratio by using Motion Controller in LPM. The LPM is operated on micro-stepping drive, that the linear scale is sequently returned the position signals of a micro-meter And next micro-step is controlled with the scale factor when position error is occurred. The scale factor is experimently acquired.

  • PDF

A DC Ripple Voltage Suppression Scheme by Harmonic Injection in Three Phase Buck Diode Rectifiers with Unity Power Factor (단위 역률을 갖는 3상 강압형 다이오드 정류기에서 고조파 주입에 의한 DC 리플전압 저감 기법)

  • 고종진
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.305-308
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode rectifiers is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode rectifiers and guarantee zero-current -switching(ZCS) of the switch over the wide load range The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. IN addition control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations.

  • PDF

A Study on Bending and Torsion Characteristics and Weight Optimization by Web Shape of Crankshaft for Diesel Engine (디젤 엔진의 Crankshaft Web 형상에 따른 굽힘 및 비틀림 특성과 중량 최적화에 관한 연구)

  • Kim, Jang-Su;Lee, Chi-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.2
    • /
    • pp.67-72
    • /
    • 2011
  • Recently, it is possible for small sized and high speed diesel engines by development of commonrail system. And in order to increase the engine performance, the cylinder firing pressure is a tendency which increases. On the other side, the weight of engine becomes lightly in spit of high performance diesel engine. Therefore, the weight optimization for engine components is very important point on the design process. Also, the weight optimization must necessarily be considered the robust design against a fatigue failure. This paper focuses on the weight optimization of crankshaft according to web shape at the light duty diesel engine, and torsion characteristics of crankshaft is considered with 1D and 3D analysis tools.

Isolated PFC Converter Based on an ADAB Structure with Harmonic Modulation for EV Chargers

  • Choi, Seung-Won;Kim, Yoon-Jae;Lee, Il-Oun;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.383-394
    • /
    • 2018
  • This paper presents an isolated power factor correction converter for general-purpose electric vehicle chargers with a wide output voltage range. The converter is based on an asymmetrical dual active bridge structure so that the voltage stress of switching devices can be eliminated by transferring the transformer leakage inductance to the circuit parameters. Harmonic and output controls are performed by secondary switches, and primary switches are only operated at a fixed frequency with a 50% duty ratio. A harmonic modulation technique is also adopted to obtain a near-unity power factor without input current monitoring. The feasibility of the proposed charger is verified with a 3.3 kW prototype.

A Study on Novel Step-Up AC-DC Chopper of High Efficiency by using Lossless Snubber Capacitor (새로운 무손실 스너버 커패시터를 이용한 고효율 스텝 업 AC-DC 초퍼에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Sang-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1103-1104
    • /
    • 2008
  • In this paper, authors propose a novel step-up AC-DC chopper operated with power factor correction (PFC) and with high efficiency. The proposed chopper behaves with discontinuous current control (DCC) of input current. The input current waveform in the proposed chopper is got to be a discontinuous sinusoid form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC chopper, the switching devices are turned-on with the zero current switching, but turn-off of the switching devices is switched at current maximum value. To achieve a soft switching of the switching turn-off, the proposed chopper is used a new partial resonant circuit. The result is that the switching loss is very low and the efficiency of chopper is high.

  • PDF

Design of New Current Full-Bridge Resonant Inverter for Induction Heating System (유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계)

  • Lee, Sang-Hun;Lim, Sang-Kil;Song, Seung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.