• Title/Summary/Keyword: Duty 비

Search Result 345, Processing Time 0.026 seconds

Review of 2014 Major Medical Decisions (2014년 주요 의료판결 분석)

  • Jeong, Hye Seung;Lee, Dong Pil;Yoo, Hyun Jung;Lee, Jung Sun
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.1
    • /
    • pp.155-190
    • /
    • 2015
  • The court sentenced meaningful decisions related to the medical service in 2014. The court assumed the negligence of medical staff in the accident if being broken while using the medical equipment for not an original purpose at the time of surgery and ruled that the compensation for damage can be recognized in recognition of the causal relationship between the explanation duty violation and side effect's happening when unproven surgery on safety is implemented regarding the duty of explanation, that in the case of cosmetic surgery, the subject on the duty of explanation needs to be expanded compared to the general medical practice and that the duty of explanation cannot be accepted for the range that cannot be expectable. Also, the court has provided the requirement and limitation of self-determination exercise in case of the crash between patient's self-determination and doctor's duty of care and has ruled that as automobile insurance contract is a contract with the insurance company to pay regarding liability for car accidents, treating patients and taking the insurance money is not illegal activity even for the unlicensed hospital violating the medical law while established. The judgment stating the opinion that medical practitioners cannot be punished according to the medical law prohibiting the receiving of rebate in case that medical practitioners did not receive benefit while the medical institution itself gained an unfair economic benefit also stands out. And the court has ruled that even if the medical institution who received a business suspension is closed, the suspension is still effective in case that the same operator opens a new medical institution in the same place, ruled on the requirement to conduct a medical service outside of the medical institution that the doctor opened and ruled that the administrative penalty cannot be conducted prior to the conviction on charge of violating the medical law.

  • PDF

Performance Comparison and Its Verification of Spectrum Sharing Technologies Using Interference Load Concept (간섭부하 개념을 이용한 주파수 공동사용 기술의 성능비교 및 검증)

  • Lee, Sangjoon;Um, Jungsun;Yoon, Hyungoo;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.3
    • /
    • pp.177-185
    • /
    • 2017
  • In this paper, we proposed a concept of interference load to analyze the performance of spectrum sharing technologies in unlicensed frequency bands. The interference load can quantitatively compare the technical properties of various spectrum sharing technologies, such as frequency hopping(FH), duty cycle(DC), listen-before-talk(LBT). Therefore, it can help to evaluate whether a local regulation about spectrum sharing is reasonably established or not. In order to verify the suggested concept, we applied it to 2.4 GHz frequency bands. Also, we demonstrated a real-time test-bed. Two bit error rate(BER) curves for FH with 10 random channels and DC of 10 %, show such good agreement that our proposed concept is expected to be widely used to assess various spectrum sharing technologies.

Control and Operating Characteristics of Three-Phase Matrix Converter with Unity Power Factor by Direct Duty-Ratio Modulation Method (단위 역률을 갖는 직접 시비율 변조방식 3상 매트릭스 컨버터의 제어 및 동작 특성)

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • This paper investigates operating characteristics of three-phase matrix converter with unity input power factor by direct duty-ratio pulse-width modulation in the case of balanced and unbalanced load. It can be found from the system analysis that (1) The control algorithm for unity power factor is not related to the variables of load sides but the input voltages, (2) With the balanced three-phase load except for the pure reactive load, the unity input power factor can be achieved, (3) In the case of the unbalanced linear load, the equivalent input characteristics of the matrix converter can be seen like the nonlinear resister, (4) When the input frequency and the output frequency have the specific relationship, each input phases have the same sharing of the average power. The feasibility and validity of the analysis were verified by simulation and experimental results.

Frame/Slot Allocation Method for Real-time Traffic in IEEE 802.15.4 Wireless Sensor Networks (IEEE 802.15.4 무선센서네트워크의 실시간 트래픽 처리를 위한 프레임/슬롯 할당방법)

  • Kim, Hyung-Seok
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.3
    • /
    • pp.49-56
    • /
    • 2007
  • The IEEE 802.15.4 low rate wireless personal area network is a protocol suitable for wireless sensor networks. Thus there has been growing interest in the IEEE 802.15.4 protocol in the home automation networks. This paper proposes a scheduling scheme obtaining optimal parameters regarding the IEEE 802.15.4 frame and subframes in the home automation networks. Guaranteed time slots (GTS) are exploited for the delivery of real-time traffic. Given a set of the requirements for bandwidths and periods assigned to nodes in the network, the beacon interval and the active/inactive subframe duration satisfying the requirements are selected considering the low duty cycle by the proposed scheme. Based on these parameters, analytic results provide the way to efficient use of network resources including energy.

Analysis of Cylinder Swirl Flow and Lean Combustion Characteristics of 3rd Generation LPLI(Liquid Phase LPG Injection) Engine (제3세대 LPLI 엔진 연소실내 스월유동 및 희박연소 특성 해석)

  • Kang, Kern-Yong;Lee, Jin-Wook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • The intake swirl motion, as one of dominant effects for an engine combustion. is very effective for turbulence enhancement during the compression process in the cylinder of 2-valve engine. Because the combustion flame speed is determined by the turbulence that is mainly generated from the mean flow of the charge air motion in intake port system. This paper describes the experimental results of swirl flow and combustion characteristics by using the oil spot method and back-scattering Laser Doppler velocimeter (LDV) in 2-valve single cylinder transparent LPG engine using the liquid phase LPG injection. For this. various intake port configurations were developed by using the flow box system and swirl ratios for different intake port configurations were determined by impulse swirl meter in a steady flow rig test. And the effects of intake swirl ratio on combustion characteristics in an LPG engine were analyzed with some analysis parameters that is swirl ratio. mean flow coefficient, swirl mean velocity fuel conversion efficiency. combustion duration and cyclic variations of indicated mean effective pressure(IMEP). As these research results, we found that the intake port configuration with swirl ratio of 2.0 that has a reasonable lean combustion stability is very suitable to an $11{\ell}$ heavy-duty LPG engine with liquid phase fuel injection system. It also has a better mean flow coefficient of 0.34 to develope a stable flame kernel and to produce high performance. This research expects to clarify major factor that effects on the design of intake port efficiently with the optimized swirl ratio for the heavy duty LPG engine.

Adaptive Mobile Sink Path Based Energy Efficient Routing Protocol for Wireless Sensor Network (무선 센서 네트워크에서 에너지 효율을 고려한 모바일 sink의 적응적 경로설정 방법)

  • Kim, Hyun-Duk;Yoon, Yeo-Woong;Choi, Won-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12A
    • /
    • pp.994-1005
    • /
    • 2011
  • In this paper, we propose a novel approach to optimize the movement of mobile sink node, called AMSP(Adaptive Mobile Sink Path) for mobile sensor network environments. Currently available studies usually suffer from unnecessary data transmission resulting from random way point approach. To address the problem, we propose a method which uses the Hilbert curve to create a path. The proposed method guarantees shorten transmission distance between the sink node and each sensor node by assigning orders of the curve according to sensor node density. Furthermore, The schedule of the sink node is informed to all of the sensing nodes so that the Duty Cycle helps the network be more energy efficient. In our experiments, the proposed method outperforms the existing works such as TTDD and CBPER by up to 80% in energy consumption.

Three Phase Quasi Z-source AC/AC Power Converter Using a Simple Duty Cycle Control Scheme (간단한 듀티비 제어기법에 의한 3상 Quasi Z-소스 AC/AC 전력 변환기)

  • Eom, Jun-Hyun;Jung, Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.435-436
    • /
    • 2016
  • 본 논문에서는 3상 Quasi Z-소스 AC/AC 전력변환기를 제안한다. 제안된 전력변환기는 3대의 단상 Quasi Z-소스 AC/AC 컨버터로 구성되어 있으며, 간단한 듀티 비 제어만으로도 동상 및 역상의 벅-부스트 출력 전압의 발생이 가능하다. 제안된 방식은 PSIM 시뮬레이션을 통하여 타당성을 확인하였다.

  • PDF

EDISON-CFD를 활용한 대형 트럭 디플렉터 형상에 따른 항력 감소 효과에 관한 연구

  • Park, Sang-Hyeon
    • Proceeding of EDISON Challenge
    • /
    • 2016.11a
    • /
    • pp.1-3
    • /
    • 2016
  • 대형 화물 트럭(heavy-duty truck)은 화물 적재에 용이하지만, 공기역학적으로 불리한 형상을 가진다. 이러한 단점을 극복하고자 대형 화물 트럭에는 공기저항력(aerodynamic drag)을 줄일 수 있는 여러 가지 장치가 달려있다. 본 논문에서는 디플렉터(deflector) 형상이 항력 감소에 어떠한 영향을 주며, 평판 형태와 굴곡진 형태의 디플렉터 형상에 대한 항력 계수 비교를 EDISON-CFD를 활용하여 비교하였다. 해석 결과, 측풍(side-wind)의 영향을 무시하며 차량 속도 95 km/h로 등속을 유지하는 조건에서 평판 형태의 Model 1과 바깥으로 굴곡진 Model 2에서 전체 항력 계수가 낮게 나타났다.

  • PDF

Design of Bidirectional DC-DC Converter for EDLC with the Consideration of High-frequency Transformer Turn-ratio (슈퍼커패시터용 양방향 DC-DC 컨버터의 고주파변압기 권선비를 고려한 설계)

  • Koo, Beob-Jin;Kim, Hak-Soo;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.145-146
    • /
    • 2013
  • 본 논문은 슈퍼커패시터용 양방향 DC-DC 컨버터의 고주파 변압기 권선비를 고려한 설계에 대해 다루었다. 양방향 DC-DC 컨버터는 슈퍼커패시터의 충전시 스위칭 손실을 줄이기 위해 듀티(Duty)를 제어하여 Buck 모드로 동작하고, 방전시 부하변동에 빠르게 대처하기 위해 Phase-shift 모드로 동작한다. 충전시와 방전시 각각의 동작에서 스위치손실과 변압기의 손실을 분석하여 손실을 최소로하는 변압기 권선비를 선정하고자 한다.

  • PDF

Implementation of Non-time-varying Duty Ratio transfer function for Improvement of control characteristics bi-directional charger (비시변 시비율 전달함수 구현에 의한 양방향충전기 제어특성 개선)

  • Hwang, Jung Goo;Kim, Sun Pil;Park, Sung Jun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.20-21
    • /
    • 2013
  • 본 논문에서는 양방향 충전기용 DC/DC 컨버터와 같이 입력전압과 출력전압이 가변하는 제어시스템에서 비시변 시비율 전달함수를 구현하여 제어특성을 개선하고자 한다. 기존제어기 설계에 의해 설계된 이득을 사용하여 제어를 행할 경우 입력전압의 변동에 따라 제어특성이 가변한다. 전압제어기의 각 이득을 시비율의 역수를 취하여 변화함으로서 전체 제어블록에서 시비율 항을 등가적으로 제거할 수 있는 방법이다. 따라서 본 논문에서 제안된 비시변 시비율 전담함수를 양방향 충전기용 DC/DC컨버터에 적용하여 PSIM을 이용한 시뮬레이션과 실험을 통해 타당성과 우수성을 검증하였다.

  • PDF