• Title/Summary/Keyword: Dust reduction

Search Result 275, Processing Time 0.031 seconds

Fine Dust Adsorption Properties of Cement Matrix Mixed with Expanded Graphite (팽창흑연을 혼입한 시멘트 경화체의 흡착 특성)

  • Lee, Jin-Won;Lee, Chang-Woo;Hwang, Woo-Jun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.105-106
    • /
    • 2022
  • Now, the world is increasingly anxious about fine dust due to abnormal temperatures caused by global warming and increased yellow dust caused by desertification, and the World Health Organization (WHO) pointed out that more than 99% of the world's population is exposed to fine dust. In this situation, the reduction rate of fine dust and carbon dioxide of the matrix was tested by using expanded graphite, an eco-friendly and porous material, to improve air quality. As a result of the test, since expanded graphite is a material that expands between layers compared to conventional graphite, the reduction rate of fine dust and carbon dioxide decreases as the replacement rate of expanded graphite increases.

  • PDF

Assessment of Dust Reduction in the Enclosed Pig Building by Spraying Method with Liquid Additives (액상 첨가제 살포 방법에 의한 밀폐형 돈사에서의 분진 저감 평가)

  • Kim, K.Y.;Ko, Han-Jong;Kim, C.N.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.97-104
    • /
    • 2008
  • Appropriate air quality in the pig building is essential to prevent farmers' health as well as to increase pig performance. This on-site experiment was conducted to assess dust reduction efficiencies of several liquid additives with spaying method in the enclosed pig building. The mean reduction rate of total dust only after spray was approximately 30% for all the treatments compared to initial level before spraying additives, which was found to reduce the initial level of total dust significantly (p<0.05). The mean reduction rate of all the treatments at 1hr after spray was about 24% which was 6% lower than only after spray. Since 3hr after spray, however, total dust level were fluctuated variably for all the treatments besides application of the soybean oil. Based on this result, effect of soybean oil on dust reduction in the enclosed pig building was most prominent among liquid additives evaluated in terms of efficiency and duration.

  • PDF

The Direct Recycling of Electric Arc Furnace Stainless Steelmaking Dust

  • Zhang, Chuanfu;Peng, Bing;Peng, Ji;Lobel, Jonathan;Kozinski, Janusz A.
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.404-408
    • /
    • 2001
  • This paper focuses on the pilot-scale investigation of direct recycling of electric arc furnace (EAF) stainless steelmaking dust. The direct recycling of EAF dust is to make pellets with the mixture of the dust and the reducing agent carbon, then introduce the pellets to the EAF. The valuable metals in the dust are reduced and get into the steel as the alloying elements. Experiments simulating direct recycling in an EAF were performed using an induction furnace. But it seems difficult to reduce all metal oxides in the dust so that some metal reducing agents added in the late stage of reduction process. The valuable metals in the dust were reduced partly by carbon and partly by metal reducing agent for the economical concern. The recovery of iron, chromium and nickel from the flue dust and the amount of metal oxides in the slag were measured. The results showed that the direct recycling of EAF stainless steelmaking dust is practicable. It wes also found that direct recycling of flue EAF stainless steelmaking dusts does not affect the chemistry and quality of stainless steel produced in the EAF. It is benefit not only for the environmental protection but also for the recovery of valuable metal resources in this way.

  • PDF

Optimization of Fugitive Dust Control System for Meteorological Conditions (기상조건별 비산먼지 관리체계 최적화 연구)

  • Kim Hyun-Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.573-583
    • /
    • 2005
  • Fugitive dust, which is emitted in the ambient air without first passing through a stack or duct designed to control flow, is frequently generated by means of wind erosion from storage yards at Pohang Steel Wokrs. The size distribution of fugitive dust is mostly in the range of coarse particulate which is deposited as soon as emitted and less harm to human health; however $20\%$ of fugitive dust contains PM 10 known as one of most harmful airborne pollutant. Consequently, effective control and reduction of fugitive dust is strongly requested by the local society, but it is not easy so far because the generation and dispersion of fugitive dust highly depends on meteorological conditions, and it being occurred for irregularity. This research presented a fugitive dust control system for each meteorological condition by providing statistical prediction data obtained from a statistical analysis on the probability of generating the threshold velocity at which the fugitive dust begins to occur, and the frequency occurring by season and by time of the wind direction that can generate atmospheric pollution when the dispersed dust spreads to adjacent residential areas. The research also built a fugitive dust detection system which monitors the weather conditions surrounding storage yards and the changes in air quality on a real-time basis and issues a warning message by identifying a situation where the fugitive dust disperses outside the site boundary line so that appropriate measures can be taken on a timely basis. Furthermore, in respect to the spraying of water to prevent the generation of fugitive dust from the storage piles at the storage yard, an advanced statistical meteorological analysis on the weather conditions in Pohang area and a case study of fugitive dust dispersion toward outside of working field during $2002\∼2003$ were carried out in order to decide an optimal water-spraying time and the number of spraying that can prevent the origin of fugitive dust emission. The results of this research are expected to create extremely significant effects in improving surrounding environment through actual reduction of the fugitive dust produced from the storage yard of Pohang Steel Works by providing a high-tech warning system capable of constantly monitoring the leakage of fugitive dust and water-spray guidance that can maximize the water-spraying effects.

A Study on the Reduction of Electric Arc Furnace Dust with Carbon (탄소에 의한 전기로 분진의 환원반응에 관한 연구)

  • 진영주;김영진;박병구;이광학;김영홍;이재운
    • Resources Recycling
    • /
    • v.7 no.3
    • /
    • pp.27-35
    • /
    • 1998
  • EAF dust generated from electric arc steelmaking process is classified as "hazardous" materials by tbe environmental regulation because of the existence of water leachable heavy metals such as Fe, Zn, Pb, and Cd. However, Fe and Zn among t the elements in the dust can be recovered to high valuable materials by applying a proper process. Therefore, in order to study t the possibility of recovery of iron from EAF dust, the effect oE carbon content and basicity, of synthesized EAF dust on the reduction rate of iron oxide was studied. Experimental results are as follows: TIle softening and melting temperature of the slag w was illcreased with increasing carbon addition amount [or carbon reduction eqUIvalent. At the carbon addition amount of 100% for carbon reduction equivalent and basicity of 1.7, reduction rate of $Fe_2O$ in the slag was the highest. The reaction order fur reduction of $Fe_2O$ by carbon was nearly first order.

  • PDF

An Analysis of Effects of Emergency Fine Dust Reduction Measures and National Petition Using Regression Analysis and Text Mining (회귀분석과 텍스트마이닝을 활용한 미세먼지 비상저감조치의 실효성 및 국민청원 분석)

  • Kim, Annie;Jeong, So-Hee;Choi, Hyun-Bin;Kim, Hyon Hee
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.11
    • /
    • pp.427-434
    • /
    • 2018
  • Recently, the Seoul government implemented 'Free Public Transportation' policy and 'Citizen Participatory Alternative-Day-No-Driving' system as 'Emergency Fine Dust Reduction Measures'. In this paper, after identifying the effectiveness of the two traffic policies, suggestions for direction of future fine dust policy were made. The effect of traffic on the fine dust was analyzed by regression analysis and the responses to the two traffic policies and petitions were analyzed using text mining. Our experimental results show that the responses to the policy were mostly negative, and the influence of the domestic factors was considerable unlike expectation of citizens. Moreover, the result made us possible to know people's specific needs on fine dust reduction policy. Finally, based on the result, the suggestions for fine dust reduction policy direction were provided.

Analysis of Prerequisites for Using Surveillance Drones and Water Fog Spraying Drones for Fine Dust Reduction in Smart Construction (스마트건설에서 미세먼지 저감을 위한 감시드론 및 Water Fog 분사 드론을 활용하기 위한 사전 요건 분석)

  • Kim, Young Hyun;Han, Jaegoo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.249-250
    • /
    • 2021
  • The use of smart equipment such as drones is increasing in construction sites. In particular, there are frequent cases where two or more drones must be used at the same time. This leads to different considerations than when operating a single unit. This study aims to analyze the requirements to be considered in the case of the operation of drones that monitor fine dust and drones that reduce fine dust in order to reduce fine dust generated in construction sites.

  • PDF

Reduction Kinetics of Zinc Oxide in EAF Dust (전기로 분진중 아금산화물의 환원속도)

  • Moon Seok Min;Kim Tae Wook;Min Dong Joon
    • Resources Recycling
    • /
    • v.11 no.4
    • /
    • pp.37-43
    • /
    • 2002
  • As the consumption of galvanized steels in cans and automobiles and the quantity of scraps increase, the recycling problems of EAF dust become a important problem. Valuable metals such as Fe, Zn, Pb are of continued interest to metallurgists. To recover the valuable metal and to remove the toxicity of EAF dust, high temperature smelting process is or researching as a pilot scale. The Reduction kinetics of Zn in EAF dust is so important in a view of the economic consideration of the process. In this study, the kinetics behavior of Zn in EAF dust were measured as a point of application in high temperature smelting process. The rate control step in ZnO and franklinite is revealed to be chemical reaction on the reaction surface.

A Study on the Economic Analysis of Low-Temperature SCR Technology for NOx Reduction by Scenarios (배연탈질을 위한 저온 SCR 기술 도입에 따른 시나리오별 경제성 분석)

  • Hong, Sungjun;Lee, Youah;Jeong, Soonkwan
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.10-22
    • /
    • 2020
  • As the national demand for solving the fine dust problem has increased, the government has announced intensive measures to deal with fine dust. So recently, selective catalytic reduction(SCR) has attracted attention as a technology for removing nitrogen oxides from precursors of fine dust. In this study, the government's policies related to fine dust and the current status of market and R&D were investigated, and economic analysis by scenarios was conducted by dividing cases where SCR technology was applied to industries. The results of economic analysis for each scenario were calculated using NPV, and companies with no denitrification facilities(Case 1) introduced general SCR technologies(Scenario 1-1) and low-temperature SCR technologies(Scenario 1-2). In addition, companies that have already installed denitrification facilities(Case 2) analyzed the two categories, using the general SCR technology as it is(Scenario 2-1) and replacing it with low-temperature SCR technology(Scenario 2-2). Comparative analysis was performed based on the results of each NPV.

Dust accumulation effect on solar thermal energy systems performance

  • Alsaad, Mohammad A.
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.157-165
    • /
    • 2015
  • This research investigates the effect of natural dust accumulation on the glass cover of solar thermal energy conversion systems. Four similar, locally manufactured, flat plate solar collectors are used. All collectors are South oriented with tilt angle of $40^{\circ}$. The glass cover of one collector is kept clean of dust during the experimental period while the second collector is cleaned at the beginning of each month. The third collector is cleaned every two months while the fourth collector is kept un-cleaned throughout the experimental period of four months. The calculated parameters are the solar heat gain rates and the corresponding values of the thermal efficiency. The result of the present work indicates that the percentage of fractional reduction of the useful heat gain rate due to dust accumulation during a period of one and two months is 11.4% and 17.0%, respectively. The percentage decrease of thermal efficiency during the same duration periods is 4.0% and 6.1%, respectively. The percentage of fractional reduction of the useful heat gain rate due to dust accumulation during a period of three and four months is 27.8% and 31.9%, respectively. The percentage decrease of monthly thermal efficiency during the same duration period is 10.2% and 11.3%, respectively.