• Title/Summary/Keyword: Dust reduction

Search Result 276, Processing Time 0.028 seconds

Case Study on the Explosive Demolition of the KOGAS Office Building in Bundang District (한국가스공사 분당사옥 발파해체 시공사례)

  • Kim, Sang-min;Park, Keun-sun;Son, Byung-min;Kim, Ho-jun;Kim, Hee-do;Kim, Gab-soo
    • Explosives and Blasting
    • /
    • v.36 no.4
    • /
    • pp.48-61
    • /
    • 2018
  • This case study is concerned with the project of the explosive demolition for the KOGAS office building located in Bundang district in Seongnam city. Since the office building was a kind of long-span beam structures, a mechanical demolition method using jacking support systems was considered in the beginning of the project. With consideration of the excessive reinforcement cost, uncertainty of safety, and prolonged construction period, however, the original plan was later changed to use an explosive demolition method. For the purpose of protecting nearby buildings and facilities during the collapse process, the explosive initiation sequence was elaborately designed to bring down the building structure towards its front left corner. A total of over 550 electronic detonators (Unitronic 600) was used to sequentially initiate the explosives installed at appropriate columns in the first, second, and fifth floors. To diminish dust production, water bags of small and large sizes were respectively installed at each column and on the floors to be blasted. As such, every effort was exercised to mitigate overall noise, dust, and shock vibrations that could be generated during the explosive demolition process for the office building.

Types of Smart Bus Stop and Their Impacts on Reducing Fine Dust Concentrations in Seoul (스마트버스정류장 유형에 따른 미세먼지 농도 저감효과)

  • Seo, Jeongki;Kim, Hyungkyoo
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.39-50
    • /
    • 2021
  • This research aims to provide guidelines with the appropriate type of smart bus stop to reduce the concentration of fine dust. To this end, we divided smart bus stops into two types: closed and open bus stops. The estimated reduction effect was compared and analysed by measuring the estimated PM10 and the estimated PM2.5 at five locations inside and outside a smart bus stop located in Gangnam gu, Seoul. The effect of reducing the amount of the fine dust concentration in external space was insignificant for both types of bus stops. The different effect of reducing the concentration of the amount between in internal space was relatively significant: the fine dust concentration was 26.0 ㎍/m3 for PM10 and 20.2 ㎍/m3 for PM2.5 at open-type bus stops; whilst was 2.4 ㎍/m3 for PM10 and 1.8 ㎍/m3 for PM2.5 at closed type bus stops. Based on the findings, a closed type bus stop is recommended when considering the cost of reducing fine dust. In addition, due to the ineffectiveness of reducing the amount of fine dust from the outside of the bus stop, additional provision of smart bus stops is required particularly in locations where demand exceeds the capacity of the inside. A clear definition of smart bus stop and it's minimum standard should also be considered.

Technology Trend for Particle Matter Reduction (미세먼지 저감 기술 동향)

  • Lee, J.H.;Im, S.H.;Kim, J.H.;Song, H.Y.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.2
    • /
    • pp.83-91
    • /
    • 2019
  • In this article, we introduce examples and technologies relating to particulate matter (PM) reduction technology, for the purpose of reducing PM that harms health and affects the entire industry such as dust-sensitive semiconductor industry. First, the definition of PM and how it is generated is explained, including its effects on the human body. In addition, various methods for measuring PM are described, including examples of the restrictions on the operation of polluting vehicles and emission reduction devices. Finally, we describe techniques relating to the reduction and forecasting of PM.

Recovery of Gallium from Steelmaking Dust (제강더스트로부터 갈륨의 회수)

  • 양종규;이성식;김종화;황영길
    • Resources Recycling
    • /
    • v.2 no.4
    • /
    • pp.27-32
    • /
    • 1993
  • A process has been studied to recover gallium from steelmaking dust which had several hundreds ppm of gallium. Aqueous solution containing 38 mg/l gallium was obtained by leaching of dust with 2.25 mol/l sulfuric acid. The leach liquor contained iron and zinc about 1,000 times greater than gallium. Gallium was then concentrated by ion exchanger of chelating resin with functional group of amino carboxylic acid after reduction of ferric ion to ferrous ion and pH adjustment. Gallium was concentrated to be 13 g/l in the resulting eluate by double ion exchanges. The liquor was further treated to remove impurities by solvent extraction technique empolying TOMAC as extractant. The galluim with 99% purity was finally obtainable.

  • PDF

The Influence of the Asian Dust on the Springtime Distribution of Airborne Lead (봄철 황사의 발생과 대기 중 중금속 성분의 농도 변화 -납성분을 이용한 사례 연구)

  • Kim Ki-Hyun;Kang Chang-Hee;Lee J. -H;Choi KC;Youn YH
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.833-838
    • /
    • 2004
  • The analysis of Pb in both PM$_{2.5}$ and PM$_{10}$ fraction of aerosols was made consecutively for every spring season during four year period of 2001 through 2004. To diagnose the impact of the Asian Dust (AD) on metal concentration levels, we compared our Pb measurement data after dividing the whole data sets into AD and NAD period. The results of our analysis indicated that the concentrations of coarse particles increased significantly during the AD period, whereas an increase in the fine counterpart was of moderate degree. However, when Pb concentrations between AD and NAD were compared, the patterns were quite different. From all particle fractions, the Pb concentrations of NAD were slightly or moderately higher than those of AD. The overall results of our study suggest that an increase in particle concentrations during the AD period can cause a rather slight reduction in Pb concentration levels; this can be explained by the dilution effect associated with the increase of Pb-depleted coarse particles.s.s.

The Impact of Negative Ions and Plant Volume Changes in Space on Fine Dust Purification in the Atmosphere (공기 중 음이온과 공간 내 식물용적 변화가 미세먼지 정화에 미치는 영향)

  • Deuk-Kyun Oh;Jeong-Ho Kim
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.217-226
    • /
    • 2024
  • This study aimed to investigate the influence of anions in the air on the purification of fine dust (PM10 and PM2.5) and to evaluate the effects of plants on the generation of anions in the air and the purification of fine dust. Subsequently, the fine dust reduction models were compared according to each factor and plant volume. The characteristics of anion generation by each factor were observed to be in the order of Type N.I (negative ion generator; 204,133.33 ea/cm3) > Type P30 (plant vol. 30%; 362.55 ea/cm3) > Type C (control; 46.22 ea/cm3), indicating that the amount of anion generation in the anion generator treatment group and the plant arrangement group were approximately 4,417 times and 7 times higher, respectively, than that in the untreated group. Consequently, the fine dust reduction characteristics by anion generation source showed that for PM10, Type NI had a purification efficiency 2.52 times higher than Type C, and Type P30 was 1.46 times higher, while for PM2.5, Type NI had a purification efficiency 2.26 times higher than Type C, and Type P30 was 1.31 times higher. The efficiency of fine dust purification by plant volume was in the order of Type P20 (84.60 minutes) > Type P30 (106.50 minutes) = Type P25 (115.50 minutes) = Type P15 (117.60 minutes) > Type P5 (125.25 minutes) = Type P10 (129.75 minutes), and for ultrafine dust, Type P20 (104.00 minutes) > Type P30 (133.20 minutes) = Type P25 (144.00 minutes) = Type P15 (147.60 minutes) > Type P5 (161.25 minutes) = Type P10 (168.00 minutes). Thus, a quantitative analysis of the anions and plants for purifying fine dust and suggested matters to be considered for future green space planning and plant planting considering fine dust purification.

Investigation towards strength properties of ternary blended concrete

  • Imam, Ashhad;Moeeni, Shahzad Asghar;Srivastava, Vikas;Sharma, Keshav K
    • Advances in concrete construction
    • /
    • v.11 no.3
    • /
    • pp.207-217
    • /
    • 2021
  • This study relates to a production of Quaternary Cement Concrete (QCC) prepared by using Micro Silica (MS), Marble Dust (MD) and Rice Husk Ash (RHA), followed by an investigation towards fresh and hardened properties of blended concrete. A total of 39 mixes were cast by incorporating different percentages of MS (6%, 7% and 8%), MD (5%, 10% and 15%) and RHA (5%, 10%, 15% and 20%) as partial replacement of Ordinary Portland Cement. The workability of fresh concrete was maintained in the range of 100±25 mm by adding 0.7% of Super Plasticizer in the mix. Optimum mechanical strength was observed at combination of 8% MS+5% MD+10% RHA. Marble dust replacement from 10 to 15% and Rice husk ash replacements from 15 to 20% depicted a substantial reduction in compressive strength at all ages. Durability parameter with respect to water absorption at 28 days shows an increasing trend as the percentage of blending increases.

Examining Influences of Asian dust on SST Retrievals over the East Asian Sea Waters Using NOAA AVHRR Data (NOAA AVHRR 자료를 이용한 해수면온도 산출에 황사가 미치는 영향)

  • Chun, Hyoung-Wook;Sohn, Byung-Ju
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.1
    • /
    • pp.45-59
    • /
    • 2009
  • This research presents the effect of Asian dust on the derived sea surface temperature (SST) from measurements of the Advanced Very High Resolution Radiometer (AVHRR) instrument flown onboard NOAA polar orbiting satellites. To analyze the effect, A VHRR infrared brightness temperature (TB) is estimated from simulated radiance calculated from radiative transfer model on various atmospheric conditions. Vertical profiles of temperature, pressure, and humidity from radiosonde observation are used to build up the East Asian atmospheric conditions in spring. Aerosol optical thickness (AOT) and size distribution are derived from skyradiation measurements to be used as inputs to the radiative transfer model. The simulation results show that single channel TB at window region is depressed under the Asian dust condition. The magnitude of depression is about 2K at nadir under moderate aerosol loading, but the magnitude reaches up to 4K at slant path. The dual channel difference (DCD) in spilt window region is also reduced under the Asian dust condition, but the reduction of DCD is much smaller than that shown in single channel TB simulation. Owing to the depression of TB, SST has cold bias. In addition, the effect of AOT on SST is amplified at large satellite zenith angle (SZA), resulting in high variance in derived SSTs. The SST depression due to the presence of Asian dust can be expressed as a linear function of AOT and SZA. On the basis of this relationship, the effect of Asian dust on the SST retrieval from the conventional daytime multi-channel SST algorithm can be derived as a function of AOT and SZA.

Study on the Evaluation Criteria of Termite Dust for Rapid Control of Wooden Structures Damaged by Termites (흰개미 가해 목조건축물의 급속 방제를 위한 분말형 약제(Termite Dust) 평가 기준 연구)

  • Im, Ik Gyun;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.3
    • /
    • pp.227-235
    • /
    • 2019
  • In Korea, various methods are applied to prevent wooden structures from being damaged by termites. However, since there is no way to quickly bring toxic substances in contact with the termites inside the timber, it leads to the damage of wooden cultural property due to the prolonged period of controlling the termites. Accordingly, an indoor evaluation criteria study was conducted for the introduction of powder-type termiticides in Korea, which produced rapid control effects by drilling wood and directly contacting and transferring toxic substances inside the timber. First, contact toxicity and transfer ability of termite dusts were evaluated to establish the criteria for evaluation of effectiveness against Reticulitermes speratus. The contact toxicity confirmed 100% mortality of fipronil, deltamethrin and cyfluthrin termite dusts within 24 h of contact; however, differences occurred in the active ingredient transfer time to the sublethal. In addition, in the case of transfer ability evaluation, the rate of mortality gradually decreased under 1:9 and 1:25 ratio conditions; however, the difference in the reduction rate was identified depending on the type of termite dust. the results of the evaluation of compressive strength of the wood showed that the difference in the measured values between the control group and the conditions of perforation 1 to 3 times, which does not significantly affect the compressive strength of wood. In this study, the criteria of termite dust selection and evaluation method of dust-type termiticides were presented and the applicability of the method was identified.

Analysis of the Factors Influencing PM10 & PM2.5 in Korea by Panel Quantile-Regression (패널 분위회귀분석을 통한 한국의 미세먼지 국내외 영향요인 분석)

  • Kim, Haedong;Kim, Jaehyeok;Jo, Hahyun
    • Environmental and Resource Economics Review
    • /
    • v.31 no.1
    • /
    • pp.85-112
    • /
    • 2022
  • This study analyzed the influence of domestic and Chinese factors on fine dust(PM10 & PM2.5) in Korea by using the panel quantile regression. Daily analysis was conducted for 11 regions in Korea. For domestic factors, electricity demand and traffic volume, and for Chinese factors, interaction term of Chinese three cities' fine dust and the domestic west wind are used. As a result, the influence of domestic factors was different when the domestic fine dust concentration was high and low. When the fine dust concentration was low, electricity demand had a positive effect only on PM2.5, and didn't affect PM10 in the national analysis. In regional analysis, the amount of electricity demand had a significant effect on fine dust and ultrafine dust only in the capital area and Chungcheong. Electricity demand was found to significantly increase both PM2.5 and PM10 when it was high. On the other hand, it was confirmed that the Chinese factor always had a significant effect regardless of the concentration of PM10 and PM2.5. Therefore, in order to solve the problem of high concentration of fine dust, in addition to international cooperation, the reduction of PM2.5 generated by domestic thermal power generation should also be strengthened compared to the present.