• Title/Summary/Keyword: Dust collection performance

Search Result 57, Processing Time 0.019 seconds

Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System (원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교)

  • Kim Sang-Do;Park Young-Ok;Kang Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

A Study on the Performance Test of Axial-flow Cyclone Separator (축상유입식 사이클론 집진기 성능시험에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.101-106
    • /
    • 2020
  • Along with dust collection efficiency, pressure loss is a very important cyclone operation factor. A severe rise in pressure loss causes the problem of cost. To solve the problem, the method connecting axial-vane type cyclones in parallel is suggested recently. The axial vane type cyclone dust collector applied in this study is a small portable type. Multiple cyclones are installed in a round type. The basic performance test on the axial vane type cyclone dust collector was conducted. As a result, the cut size reduced along with a rise in the wind velocity of the cyclone dust collector inlet. According to the test on dust collection efficiency, the effect of dust collection began to appear in the range of 3㎛ and dust collection efficiency was greatly improved at 5 ㎛. The noise of the cyclone dust collector well met the fan sound power level of KSB 6361.

Performance Characteristics of Louver Dust Collectors (루버 집진기의 성능특성)

  • Woo, Sang-Hee;Kim, Jong Bum;Park, Tong-Il;Yook, Se-Jin;Kwon, Soon Bark;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.11-20
    • /
    • 2016
  • A large amount of wear dust generated during train operation is a major dust source in urban railway tunnels. To check possibility of a louver dust collector for the removal of dust in the railway tunnel, five louver dust collector models were designed and their performance was tested in a wind tunnel. JIS Z 8901 Class 8 dust was used as a test dust. Pressure drop and particle collection efficiency were evaluated with the face velocity ranging from 1 m/s to 4 m/s. At this low velocity range, particle collection efficiency of the louver dust collector was found to be insensitive to air velocity and design parameters. Pressure drop was under 40 Pa, and $PM_{10}$ and $PM_{2.5}$ collection efficiencies were approximately 50% and 30%, respectively.

Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone (접선유입식과 축상유입식 사이클론의 집진효율 비교)

  • Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.115-121
    • /
    • 2011
  • This study is about comparison of tangental entry type cyclone dust collector with axial vane type cyclone dust collector. Cut diameter and dust collection efficiency of both collector was compared by theory and experiment. Cut diameter was calculated by an quasi-empirical formula by Lapple and Shepherd. Measurement of cut diameter was conducted by particle counter through dust generator. As the result, cut diameter obtained by experiment was a little larger than that by theory. But the error is within $0.5{\mu}m$ in both type of collector, so it could be confirmed that theoretical value and experimental value were almost identical. And, as flow rate increased, dust collection efficiency was increased. Also axial vane type showed higher dust collection efficiency than tangental entry type. Therefore, it can be said that axial vane type cyclone dust collector has higher performance than the other.

Effects of Spray Surfactant and Particle Charge on Respirable Coal Dust Capture

  • Tessum, Mei W.;Raynor, Peter C.
    • Safety and Health at Work
    • /
    • v.8 no.3
    • /
    • pp.296-305
    • /
    • 2017
  • Background: Surfactant-containing water sprays are commonly used in coal mines to collect dust. This study investigates the dust collection performance of different surfactant types for a range of coal dust particle sizes and charges. Methods: Bituminous coal dust aerosol was generated in a wind tunnel. The charge of the aerosol was either left unaltered, charge-neutralized with a neutralizer, or positively- or negatively-charged using a diffusion charger after the particles were neutralized. An anionic, cationic, or nonionic surfactant spray or a plain water spray was used to remove the particles from the air flow. Some particles were captured while passing through spray section, whereas remaining particles were charge-separated using an electrostatic classifier. Particle size and concentration of the charge-separated particles were measured using an aerodynamic particle sizer. Measurements were made with the spray on and off to calculate overall collection efficiencies (integrated across all charge levels) and efficiencies of particles with specific charge levels. Results: The diameter of the tested coal dust aerosol was $0.89{\mu}m{\pm}1.45$ [geometric $mean{\pm}geometric$ standard deviations (SD)]. Respirable particle mass was collected with $75.5{\pm}5.9%$ ($mean{\pm}SD$) efficiency overall. Collection efficiency was correlated with particle size. Surfactant type significantly impacted collection efficiency: charged particle collection by nonionic surfactant sprays was greater than or equal to collection by other sprays, especially for weakly-charged aerosols. Particle charge strength was significantly correlated with collection efficiency. Conclusion: Surfactant type affects charged particle spray collection efficiency. Nonionic surfactant sprays performed well in coal dust capture in many of the tested conditions.

Development of Cyclone Conveying System for Transporting Chopped Round Bale Roughage and Separating Dust (흙먼지 분리기 용이한 원형베일 세절 조사료의 사이클론 이송장치 개발)

  • Ha, Yu-Shin;Kwon, Jin-Kyung;Park, Kyung-Kyoo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.204-210
    • /
    • 2011
  • This study developed the cyclone conveying system using roughage cutter for the round bale reported in the previous papers. Performance tests were conducted whether it can easily separate dust from roughage such as rice straws and it can transport roughages from cutter to TMR mixer. In addition, the airflow patterns in the cyclone conveying system were investigated using CFD code (FLUENT 6.2) for various velocities of dust collection fan. The cyclone conveying system was designed based on dried rice straws with a diameter of 1,340 mm, a cylinder length of 1,220 mm, a cone length of 850 mm and the current velocity of the dust collection fan was 15~20 m/s. It was found that transporting of roughage from cutter to TMR mixer and the separation of dust were satisfactory, and the dust removal rate of rice straws was around 31.9%. CFD analysis showed that, at the blowing fan velocity of 11.6 m/s, the airflow velocity inside the dust collector increased as velocity of the dust collection fan increased, but the airflow patterns inside the dust collector were all much the same.

A Study on the Effect of Dust Precharging on Filtration Performance

  • Park, Y.O;Park, S.J.;Lee, J.H.;Kim, S.D.;Park, H.S.;Park, H.K.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.53-59
    • /
    • 2001
  • A hybrid dust-collector combining electrostatic charging with fabric filtration method was developed, and its performance characteristics were evaluated in this study. Charged particles build porous dendritic structure on the surfaces of filter by electrostatic attraction, increasing the collection efficiency of dust particles and reducing the pressure drop through the deposited dust layer and filter media. The cleaning performance of the dust layer is improved because the dendritic structured dust layer can be removed more easily by pulse jet cleaning flow. The results of the experiment showed a reduction of fine particle emission of 37% and the energy saving of 13% by precharging dust particles before filtration.

  • PDF

Aanalyze the Fluid Inside the Ceramic Filtration Dust Collection System (세라믹 필터 집진기의 유동 해석)

  • Jang, Sung-Cheol;Choi, Dong-Soon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.1
    • /
    • pp.67-73
    • /
    • 2017
  • This study aimed to analyze the fluid inside the ceramic filtration dust collection system which was assumed to be a stationary 3-dimensional turbulence. The fluid dynamics data necessary for performance curves were obtained based on the analysis results. The governing equations used to compute the velocity distribution and pressure inside the catalyst converter were expressed with continuity and momentum equations. Furthermore, the ${\kappa}-{\varepsilon}$ turbulence model, already validated by the industry(coal factory, high temperature dust collector) was used for the study. Of a total of three computational models employed, Model-1 served as the basis for CFD analysis which took measurements in increments of 70mm.

A Study on Performance Improvement of Light and Low-Noisy Standing Grinder with Vacuum Dust Collection Using a Cyclone Separator (사이클론을 활용한 경량.저소음 진공집진 스탠딩 그라인더의 성능개선에 관한 연구)

  • Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4732-4737
    • /
    • 2011
  • A standing grinder with a vacuum dust collection, which works grinding a surface and collecting dust occurred simultaneously, is needed to clean the surface before painting, or to remove a weld bead burr in the industrial field. In recent it trends to be compact and potable with high grinding and dust collection power, and low noise. As increasing these grinding and dust collection power, the noise and weight of standing grinder occurs an important problem. To solve these problem, an efficient cyclone separator was designed and developed by Ansys-CFX analysis and experiments. A weight of the developed grinder part was 5.9kg, which can be easily handled on standing by workers. and a noise level of the developed prototype was measured 69.9 dB(A).

A study on cleaning performance of particles on collection plates using an electrodynamic screen (전기역학적 스크린을 이용한 집진판 표면 위 입자 세정성능 연구)

  • Yunhui Joe;Dongho Shin;Younghun Kim;Inyong Park;Sang Bok Kim;Gunhee Lee;Bangwoo Han
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.63-76
    • /
    • 2023
  • An electrostatic precipitator (ESP) has a low pressure drop and a high collection efficiency but its collection efficiency can be reduced due to dust accumulation on the collection plates during long-term operations. In order to maintain the initial dust collection efficiency, it is necessary to periodically clean the collection plates. The common cleaning methods are using physical impacts or water sprays. These cleaning methods can lead to damage to the collection plate or generate wastewater. Herein, we implemented an electrodynamic screen (EDS) for ESP cleaning and evaluated its surface cleaning performance of particles. The EDS is an electrostatic system that can electrostatically repel particles on surfaces, allowing it to clean the ESP without causing damage and wastewater generation. Our evaluation included the analysis of the effects of AC voltage characteristics, electrode configuration and environmental conditions on the cleaning performance of the EDS with the aim of achieving effective surface cleaning. It has been demonstrated that activating the EDS cleans up to 65% of the particles on the surface, which indicates about 94% of our target cleaning zone.