• Title/Summary/Keyword: Dust collection

Search Result 186, Processing Time 0.031 seconds

Dust collection system optimization with air blowing and dust suction module (에어 블로어와 흡입기능을 가진 미세먼지 흡입시스템의 최적화)

  • Jeong, Wootae;Kwon, Soon-Bark;Ko, Sangwon;Park, Duckshin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.290-297
    • /
    • 2016
  • The performance of track cleaning trains to remove accumulated fine particulate matter in subway tunnels depends on the design of the suction system equipped under the train. To increase the efficiency of the suction system under the cleaning vehicle, this paper proposes a novel dust suction module equipped with both air blowing nozzles and a dust suction structure. Computational Fluid Dynamics (CFD) analysis with turbulent flow was conducted to optimize the dust suction system with a particle intake and blowing function. The optimal angle of the air blowing nozzle to maximize the dust removal rate was found to be 6 degrees. The performance of the track cleaning vehicle can be increased by at least 10 percent under an operation speed of 5km/h.

Occupational exposure to dust and respirable quartz in coal briquettes ash handling worker (연탄재 처리 환경미화원의 분진 및 호흡성 석영 노출)

  • Kim, Boowook
    • Particle and aerosol research
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study is to assess respirable crystalline silica (RCS) exposure levels in workers who collect and dispose used coal briquette ash (CBA) in sanitation companies that are subcontracted by one medium-sized local government on the collection of municipal household waste (MHW), and to analyze the quartz content in CBA. When the CBA powder that undergone specialized pretreatment in several steps were subjected to mineral identification and quantitative analysis using X-ray diffraction (XRD), it was found that quartz represented 18%, and in addition, mullite, and plagioclase were included. For two CBA collectors, samples were collected by the personal sampling evaluation method. After respirable dust was collected in accordance with the National Institute for Occupational Safety and Health 7500 method, the concentration of quartz was analyzed using XRD. Meanwhile, a portable real-time dust monitor (Sidepak AM520, TSI Inc., USA) was also used to observe the dust exposure level for each time zone and job task. The RCS exposure level of one worker was as high as 0.024 mg/㎥, which was the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLV) level. The other worker also exhibited a concentration of 0.013 mg/㎥, which was more than half of TLV. The Sidepak results revealed that the work of collecting CBA and loading it onto a vehicle was hardly exposed to the dust of a significant level. It was found, however, that the work of transferring the collected CBA to a container through a conveyor belt was exposed to a very high average respirable dust concentration of 2.238 mg/㎥. The results of this study confirmed that quartz, which is crystalline silica and a carcinogen, is contained in CBA, one of municipal household waste (MHW), in high concentration. It was also confirmed that workers are exposed to high RCS concentrations while transferring collected CBA into a container. Although each local government in South Korea handles CBA in different ways, it is imperative to investigate the CBA exposure level of sanitation workers and improve their working conditions.

The Impact of Particulate Matter and Public Awareness on the Incidence of Asthma (미세먼지 농도 및 대중의 인식도가 천식질환 발생빈도에 미치는 영향 분석)

  • Ki-Kwang Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.4
    • /
    • pp.32-38
    • /
    • 2023
  • This study investigates the influence of particulate matter concentrations on the incidence of asthma, focusing on the delayed onset of symptoms and subsequent medical consultations. Analysis incorporates a four-day lag from the initiation of fine dust exposure and compares asthma patterns before and after the World Health Organization's (WHO) classification of fine dust as a Group 1 carcinogen in November 2013. Utilizing daily PM10 data and asthma-related medical visit counts in Seoul from 2008 to 2016, the study additionally incorporates Google search frequencies and newspaper article counts on fine dust to assess public awareness. Results reveal a surge in search frequencies and article publications after WHO announcement, indicating heightened public interest. To standardize the long-term asthma occurrence trend, the daily asthma patient numbers are ratio-adjusted based on annual averages. The analysis uncovers an increase in asthma medical visits 2 to 3 days after fine dust events. Additionally, greater public awareness of fine dust hazards correlates with a significant reduction in asthma occurrence after such events, even within 'normal' fine dust concentrations. Notably, behavioral changes, like limiting outdoor activities, contribute to this decrease. This study highlights the importance of analyzing accumulated medical data over an extended period to identify general public behavioral patterns, deviating from conventional survey methods in social sciences. Future research aims to extend data collection beyond 2016, exploring recent trends and considering the potential impact of decreased fine dust awareness amid the COVID-19 pandemic.

A study on Characteristics of Airborne Dusts in Seoul Subway Stations (서울 지하철 내 공기 중 먼지의 특성에 관한 연구)

  • 김진경;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.154-160
    • /
    • 2004
  • The purpose of this study was to evaluate airborne concentrations and characteristics of TSP, IPM, TPM and RPM in Seoul subway stations. Sampling was performed at 14 stations from April 11 to 29, 2002. Size-selective dust concentrations and metal concentrations were measured by gravimetric method and ICP-AES, respectively. The geometric mean of TSP, IPM, TPM and RPM concentrations in Seoul subway stations were 176$\mu\textrm{g}$/㎥, 348$\mu\textrm{g}$/㎥, 158$\mu\textrm{g}$/㎥ and 104$\mu\textrm{g}$/㎥, respectively. Dust concentrations in pathway were the highest and those in lobby were the lowest. The size distribution of dusts was significantly different by location of collection. When the deposition rate into pulmonary gas exchange region was estimated by size distribution, the deposition rate of dust collected from platform was higher than those of dust collected from lobby and pathway. The lower the basement levels were, the higher the deposition rates of dusts into tracheobronchial region and gas exchange region were. Copper and iron concentrations measured in platform higher were than those in other areas.

Patent Technologies for Reducing Micro-Dust (미세먼지 저감을 위한 특허기술들)

  • Cho, Taejun;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.9-14
    • /
    • 2020
  • Four developed patents have applied for a new type of Composite Cyclone Scrubber followed by the previous research (Cho and Kim, 2017), including dust reducing fan with filters. Regarding target installation and maintenance cost, 64% reduction for investment costs (6.2 billion won vs. 17 billion won) compared to existing road pollution reduction system, while social benefit costs increase by 43% compared to existing road pollution reduction measures (72.6 billion won vs. 50.8 billion won). The composition of the device is an air blower type spiral guide vane, and an injection pressure collecting dust efficiency. A nozzle varies Injection angle and contact range, spray liquid species (waterworks, salty water). The proposed patent tests are circulation water Time-by-Time Spray and collected 41.4% more increased micro dust since the sprayed water meets contaminated gas due to the 45° degree colliding, which is 141% increased conventional dust collector. (Ratio of collection over 85%). As regards the source of collection liquid, circulated rainwater and well water, we expect a huge amount of energy and economically saved eco-friendly system in our patent. Finally, the guided vane and metal filter reduced over 90% micro-dust, while sprayed water cleans the vane and filters, resultantly minimizing the maintenance budget. The preliminary evaluations of the developed design make it possible to reduce not only cheaper maintenance budget due to the characteristic water spraying but the cost of water comes from mainly rain and underground.

Performance of High Temperature Filter System for Radioactive Waste Vitrification Plant (방사성폐기물 유리화 플랜트 고온여과시스템의 성능 특성)

  • Seung-Chul, Park;Tae-Won, Hwang;Sang-Woon, Shin;Jong-Hyun, Ha;Hey-Suk, Kim;So-Jin, Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Important operation parameters and performance of a high temperature ceramic candle filter system were evaluated through a series of demonstration tests at a pilot-scale vitrification plant. At the initial period of each test, due to the growth of dust cake on the surface of ceramic candles, the pressure drop across the filter media increased sharply. After that it became stable to a certain range and varied continuously proportion to the face velocity of off-gas. On the contrary, at the initial period of each test, the permeability of filter element decreased rapidly and then it became stable. Back flushing of the filter system was effective under the back flushing air pressure range of 3∼5 bar. Based on the dust concentrations measured by iso-kinetic dust sampling at the inlet and outlet point of HTF, the dust collection efficiency of HTF evaluated. The result met the designed performance value of 99.9%. During the demonstration tests including a hundred hour long test, no specific failure or problem affecting the performance of HTF system were observed.

  • PDF

Collection Characteristics of Multi-layer Multi-stage Porous Plate System (다층 다단 다공성 플레이트 시스템의 집진 특성)

  • Kim, I.K.;Yoa, S.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.10-16
    • /
    • 2010
  • The main object of this study is to investigate the collection characteristics of multi-layer multi-stage porous plate system experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as inlet velocity, tube diameter, inlet concentration, and stage number, etc. In results, the pressure drop becomes 22 to $115mmH_2O$ with increment of stage number (1 to 5) of porous plate system at tube velocity 15 m/s and tube diameter ${\Phi}8$. In case of fly ash and 5 stage, the collection efficiency becomes 90.5 to 95.7% increasing the tube velocity 12 to 15 m/s at inlet concentration $3g/m^3$ and tube diameter ${\Phi}8$. Additionally, it is estimated that the collection efficiencies of 5 stage are 94.3, 95.6 and 99.1% for fly ash, steel dust and based power, respectively (${\Phi}8$ tube, $V_t$ = 12m/s, inlet concentration $3g/m^3$).

A Study on the Fine Dust Removal Equipment of Pressurized Water type for the Removal of Exhaust Gas Fine Dust and Volatile Organic Compounds from the Non-industrial combustion plant (비산업 연소 사업장 배출 가스상 미세먼지와 휘발성 유기 화합물 제거를 위한 가압수식 미세먼지 제거 장치 연구)

  • Youn, Jae-Seo;Kim, Sang-Min;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.506-512
    • /
    • 2018
  • The fine dust generated in the home and restaurant business occupies a low ratio of about 4% of the total fine dust emissions. However, at the foodservice business, the rate of change of the pollutant concentration is very high, so that the temporary fine dust concentration can be measured up to 60 times. The pollutants generated from non-industrial combustion plants consist of particulate fine dust and gaseous organic compounds. To remove these pollutants, cleaning dust collection system, which is an effective system for simultaneous removal of gaseous and particulate matter, is applied. This is a method of increasing the probability of diffusion capture of the Brownian motion by pressurized liquid injection method using the atomizing nozzle. The dust removal efficiency of the fine dust collecting system was analyzed by nozzle spraying air pressure condition and angle using the manufactured fine dust removing system. As a result, it was confirmed that the efficiency of removal of fine dust and gaseous organic compounds was more than 90%. The developed system is expected to be highly usable in the future because it can remove particulate dust from the existing plant hood system without any installation cost.

Analysis of Water-Vapor Permeance and Ventilation Property of the Porous Construction Materials (다공성 건축자재의 투습 및 통기성 분석에 대한 연구)

  • Kim, Jong-Won;Ahn, Young-Chull
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.754-757
    • /
    • 2008
  • To maintain the indoor air quality, many ventilation systems and technologies have been developed in the highly insulated and air tight buildings. In this study, a porous construction material, which is applicable to passive ventilation system, is developed and measured the performances of the permeability and the resistance of water vapor, and the dust collection efficiency. The average coefficient of water vapor permeability shows $3.6\;g/m^2{\cdot}h{\cdot}mmHg$, which is slightly higher than Hanji ($2.4{\sim}3.2\;g/m^2{\cdot}h{\cdot}mmHg$) and the average water vapor resistance factor shows $0.303\;g/m^2{\cdot}h{\cdot}mmHg/g$, which is slightly smaller than Hanji($0.309{\sim}0.315\;g/m^2{\cdot}h{\cdot}mmHg/g$). The pressure drop of the porous construction material is smaller than the HEPA filter and the minimum dust collection efficiency shows 82.8% in the range of $2{\sim}9\;cm/s$.

  • PDF