• Title/Summary/Keyword: Dust Analysis

Search Result 949, Processing Time 0.029 seconds

Algorithm Deciding Offshore Cable Layout Valid for Integrated Power Supply Between Adjacent Islands (근거리 도서간 통합전력공급에 유효한 해저케이블 포설 방안 결정 알고리즘)

  • Kim, Mi-Young;Rho, Dae-Seok;Moon, Guk-Hyun;Seo, In-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.28-36
    • /
    • 2018
  • Islands are supplied with power from diesel generation or from photovoltaic power generation, and problems with offshore environmental impacts (age deterioration, salt pollution), environmental pollution (exhaust gas, noise, dust) and power generation costs (installation, maintenance) have increasingly emerged. In 2016, the cost recovery rate was only 27%, and deficits reached 73% on 65 islands managed by KEPCO. In terms of deficits, the costs incurred in the power generation sector accounted for 91%, with the ratio of fixed costs at about 60%. Analysis suggests that operating costs can be reduced with an optimal power supply system that improves power generation efficiency and makes operating systems more efficient. Therefore, it is possible to simplify fuel transportation and facility maintenance, because one island integrates the power plants of remote islands, and offshore cable is used to supply power to the other islands. From the economic evaluations in this paper, an algorithm deciding offshore cable layout validity for an integrated power supply between adjacent islands is presented. Simulation results based on the proposed algorithm confirmed that an integrated power supply is economical for existing stand-alone operations on islands having diesel generation, low peak power, and near distances.

Identification of PM10 Chemical Characteristics and Sources and Estimation of their Contributions in a Seoul Metropolitan Subway Station (서울시 지하역사에서 PM10의 화학적 특성과 오염원의 확인 및 기여도 추정)

  • Park, Seul-Ba-Sen-Na;Lee, Tae-Jung;Ko, Hyun-Ki;Bae, Sung-Joon;Kim, Shin-Do;Park, Duckshin;Sohn, Jong-Ryeul;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.74-85
    • /
    • 2013
  • Since the underground transportation system is a closed environment, indoor air quality problems may seriously affect many passengers' health. The purpose of this study was to understand $PM_{10}$ characteristics in the underground air environment and further to quantitatively estimate $PM_{10}$ source contributions in a Seoul Metropolitan subway station. The $PM_{10}$ was intensively collected on various filters with $PM_{10}$ aerosol samplers to obtain sufficient samples for its chemical analysis. Sampling was carried out in the M station on the Line-4 from April 21 to 28, July 13 to 21, and October 11 to 19 in the year of 2010 and January 11 to 17 in the year of 2011. The aerosol filter samples were then analyzed for metals, water soluble ions, and carbon components. The 29 chemical species (OC1, OC2, OC3, OC4, CC, PC, EC, Ag, Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Si, Ti, V, Zn, $Cl^-$, $NO_3{^-}$, $SO_4{^{2-}}$, $Na^+$, $NH_4{^+}$, $K^+$, $Mg^{2+}$, $Ca^{2+}$) were analyzed by using ICP-AES, IC, and TOR after proper pretreatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the $PM_{10}$ sources and then six sources such as biomass burning, outdoor, vehicle, soil and road dust, secondary aerosol, ferrous, and brakewear related source were classified. The contributions rate of their sources in tunnel are 4.0%, 5.8%, 1.6%, 17.9%, 13.8% and 56.9% in order.

Initial Risk Assessment of Acetanilide with Respect to Human Health (아세트아닐리드의 초기 인체위해성 평가)

  • Lee, Su-Rae;Park, Seon-Ju;Lee, Mi-Kyung;Nam, U-Kyung;Chung, Sun-Hwa;Seog, Geum-Su;Park, Kwang-Sik;Kim, Kyun;Kim, Yong-Hwa
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.1_2
    • /
    • pp.31-37
    • /
    • 2000
  • Acetanilide may be released into the environment through air and wastewater from its production and use sites and exposed to human. Acetanilide is known to produce an analgesic effect and may pose adverse effects on human health by overly exposure. According to the EUSES system, acetanilide showed a high MOS (Margin of safety) value exceeding 6$\times$10$^4$ on a regional exposure, which is safe enough for public health. Whereas the lowest MOS value in dermal exposure was estimated as 3$\times$10$^{-4}$ on a local basis (workplace), the risk could be partly counteracted by taking preventive measures such as using mask and globes and good ventilation in the work places. Acetanilide may pose a potential risk for workers by dust inhalation. For the sake of health protection in the work places, additional data should be accumulated with respect to repeated dose toxicity, reproduction toxicity and developmental toxicity, etc. It is, therefore, recommended that acetanilide should be a candidate for further work to supplement the lacking data until it is proved to be safe in the occupational health aspects.

  • PDF

A Study on the Heat Treatment Technology for Reduction of Oxidation Scales (산화피막 저감을 위한 열처리 기술에 관한 연구)

  • Koo, Hee Jun;Chung, Chan Kyo
    • Clean Technology
    • /
    • v.4 no.2
    • /
    • pp.41-53
    • /
    • 1998
  • Most of flame furnace with uncontrolled atmosphere forms oxidation scales in the surface during heat treatment. In this case, shot blasting and pickling are commonly used for reduction of oxidation scales. These processes have many disadvantages, such as long process time, high operating cost and environmental problems due to polishing dust, etc. Hence, this study aimed to develop the advanced heat treating equipment which could make a controlled atmosphere using a heatresisting structure into the flame furnace. The analysis result with SEM, EPMA, and EDX revealed that the amount of scales formed is much less than that with the conventional flame furnace. A brightness of the sample treated with the advanced process is similar compared to the treatment with vacuum furnace. In the present work, it was recommended that the inside structure of the furnace and gas line system could made up of SBB410 and STS310, respectively. The operating cost with the advanced heat treatment system could be reduced annually by forty million won. As a result of this study, it may be possible to reduce the oxidation scales. The fundamental information obtained in this study will be useful not only for improving the heat treatment process(reduction of shot blast and cleaning process), but for promoting the manufacture of bright products.

  • PDF

Characteristics of Heavy Metal Pollution in Contaminated Roadside Sediments in Jeonju City, Korea (전주시 도로변 퇴적물의 중금속 오염 특성)

  • Cho, Ktu-Seong
    • Journal of the Korean earth science society
    • /
    • v.24 no.8
    • /
    • pp.711-720
    • /
    • 2003
  • To study characteristics of the heavy metal pollution, sediment samples were collected at 67 sites on the roadside of Jeonju city during summer and winter, 2002. The total concentration of metals including Cd, Co, Cr, Cu, Ni, Pb, Zn, and Mn in the sediment samples were determined. The results indicate that the roadside sediments in Jeonju city have lower (1/2 to 1/7 times) concentrations of Zn, Cu, Pb and Cd than the metal concentrations previously reported for roadside soil, dust and sewage sludges in Seoul. However, the metal concentrations are higher than environmental quality criteria in soil suggested from several countries, and Zn, Cu, Pb and Cd contents are usually 2-7 times higher than the world average contents of the metals in natural soil. Although pollution index and concentrations of Cr, Ni, Pb and Zn in the roadside sediments at industrial area were usually higher than those of downtown and residential area, the metal having small vehicle- and steel-related industries had high concentrations of metals. The results of chemical partitioning analysis showed that Pb, Zn and Mn are mainly associated with carbonate/adsorbed and Fe-Mn oxide phases but that Cu is largely associated with the organic and sulfide fractions. It thus indicates that both large and small (vehicle- and steel-related) industries are main sources of heavy metal contamination. Due to high solubility of the carbonate phases by natural leaching episodes, the carbonate/adsorbed Cd, Co, Ni, Pb, Zn and Mn in the roadside sediments may serve as a potential source of contamination.

The Fact-finding and Analysis of the Environmental Management Cost in Construction Projects (건설공사의 환경관리비용 계상 및 운용 실태 분석)

  • Choi, Min-Soo;Kang, Woon-San
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.5 s.27
    • /
    • pp.186-192
    • /
    • 2005
  • The purpose of this study is to find the reality of environmental management cost in construction projects and to suggest some policies in order that owners appropriate the environmental management cost reasonably in the construction budget for reducing the environmental pollution at job sites. We surveyed the actual state of appropriating and expending the environmental management cost over 122 construction sites. According to the results of the survey, while the appropriated rate of the environmental management cost was 0.59% of the total construction cost. the expended rate reached at 0.94%. When examining the antipollution facilities which were operated in job sites, the investment for equipment against air-pollution such as tire washer, dust-proof device was relatively higher than other antipollution equipment. As the method appropriating the environmental management cost, we concluded that a quantity-per-unit costing method is more reasonable than appropriating at a fixed rate of total construction cost considering that there is little correlation between total construction cost and the environmental management cost. To do so, antipollution facilities that must be examined at a design or estimation stage of a construction project should be prescribed by the law. Moreover, referenced cost data for the quantity-per-unit costing should be prepared and officially published.

Fire Hazard of PP and LLDPE dust in Chemical Plant Process (석유화학플랜트에서 발생하는 PP(Poly Propylene) 및 LLDPE(Linear Low Density Poly Ethylene) 분진의 연소 위험성에 관한 연구)

  • 김정환;이창우;현성호;권경옥
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • Thermal properties of PP and LLDPE dusts from chemical plant and their risks of coexisting with oxidizer were investigated by a pressure vessel. The thermal decomposition of PP and LLDPE dusts with temperature using DSC and the weight loss with temperature using TGA were also investigated to find the thermal hazard of PP and LLDPE dusts. Using the pressure vessel which can estimate ignition and explosion of PP and LLDPE dusts coexisting with oxidizer, a series of bursting of a rupture disc, experiments has been conducted by varying the orifice diameters the weight ratio of the sample coexisting with oxidizers and the species of oxidizer. And fire gases was measured by gas analyser ($ECOM-A^+$). According to the results of the thermal analysis of PP and LLDPE dusts, the decomposition temperature range of PP and LLDPE dusts was 200 to 350 and 300 to $500^{\circ}c$, respectively. The risk of PP and LLDPE dusts coexisting with oxidizer was increased as the orifice diameter was decreased. On the other hand, it was increased as the weight ratio of the sample to the oxidizer were increased. In addition, the risk of PP and LLDPE dusts coexisting with oxidizer was affected by the decomposition temperature of the sample and oxidizer. It is found that the risk of fire becomes high when the decomposition temperature of the sample is about same as that of oxidizer. Also, the fire gases was occurred carbon monoxide and carbon dioxide. The amount of carbon monoxide generated was found to be much higher in PP decomposition than in LLDPE due to incomplete combustion of PP which has high content of carbon in chemical compound.

  • PDF

A study on unmanned watch system using ubiquitous sensor network technology (유비쿼터스 센서 네트워크 기술을 활용한 무인감시체계 연구)

  • Wee, Kyoum-Bok
    • Journal of National Security and Military Science
    • /
    • s.7
    • /
    • pp.271-303
    • /
    • 2009
  • "Ubiquitous sensor network" definition is this-Someone attaches electro-magnetic tag everything which needs communication between man to man, man to material and material to material(Ubiquitous). By using attached every electro-magnetic tag, someone detects it's native information as well as environmental information such as temperature, humidity, pollution and infiltration information(Sensor). someone connects it realtime network and manage generated information(Network). 21st century's war is joint combined operation connecting with ground, sea and air smoothly in digitalized war field, and is systematic war provided realtime information from sensor to shooter. So, it needs dramatic development on watch reconnaissance, command and control, pinpoint strike etc. Ubiquitous computing and network technologies are essential in national defense to operate 21st century style war. It is possible to use many parts such as USN combined smart dust and sensor network to protect friend unit as well as to watch enemy's deep area by unmanned reconnaissance, wearable computer upgrading soldier's operational ability and combat power dramatically, RFID which can be used material management as well as on time support. Especially, unmanned watch system using USN is core part to transit network centric military service and to get national defense efficiency which overcome the dilemma of national defense person resource reducing, and upgrade guard quality level, and improve combat power by normalizing guardian's bio rhythm. According to the test result of sensor network unmanned watch system, it needs more effort and time to stabilize because of low USN technology maturity and using maturity. In the future, USN unmanned watch system project must be decided the application scope such as application area and starting point by evaluating technology maturity and using maturity. And when you decide application scope, you must consider not only short period goal as cost reduction, soldier decrease and guard power upgrade but also long period goal as advanced defense ability strength. You must build basic infra in advance such as light cable network, frequency allocation and power facility etc. First of all, it must get budget guarantee and driving force for USN unmanned watch system project related to defense policy. You must forwarded the USN project assuming posses of operation skill as procedure, system, standard, training in advance. Operational skill posses is come from step by step application strategy such as test phase, introduction phase, spread phase, stabilization phase and also repeated test application taking example project.

  • PDF

A Study on Health Status of Workers in Metal Manufacturing Industries (금속제조 산업근로자들의 건강실태 조사)

  • 정경석
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.1
    • /
    • pp.67-80
    • /
    • 1982
  • In order to evaluate the psychosomatic health status of metal manufacturing industries workers and their working environments, the present study was conducted from March 1, 1981 to the end of September 1981. The data was obtained from the samples of metal manufacturing industries in Kyung-In Area and their 1, 162 employees. In addition, the 803 urban residents including students, office clerks, and general publics were sampled as control groups to compare with factory employees in psychosomatic analysis. The basic tool employed in the present study was the Todai Health Index (THI) which modified CMI and was developed by Tokyo University Research Team of Japan. The results of the present study were summarized as follows: 1. Working environments of the factories 1) The data shows that fabrication shop produced the highest noise level ranging from 91 to 96 dB (A) and iron and steel shop had the lowest noise level ranging from 81 to 86 dB (A). 2) Dust concentration was the highest in iron foundry shop ($3.8 mg/m^3$) and the lowest in fabrication shop ($1.2 mg/m^3$). 3) WBGT above threshold limit values (T.L.V.) was noted in steel shop (38$\circ$C) and iron foundry shop (34$\circ$C) 4) The concentration of Sulfur dioxide ($SO_2$)was 30.5ppm at steel shop and 12.0ppm at iron foundry shop. 5) The concentration of carbon monoxide (CO) was 140.0ppm at steel shop and 110.5ppm at iron foundry shop. 6) The atmospheric lead concentration was $0.49 mg/m^3$ at soldering shop. 2. The responses of psychosomatic complaints were much higher in steel shops group than in other manu-facturing group, except the response of aggressiveness. 3. The responses of psychosomatic complaints were much higher in industrial workers than in urban residents, except the responses of depression and aggressiveness (p < 0.01 ). 4. The psychosomatic symptoms which industrial workers and urban residents complained frequently were nervousness. agressiveness and lie scale in order. 5. The responses of psychosomatic complaints by sex were much higher in female group than in male group, except the response of aggressiveness. 6. The responses of psychosomatic complaints by age were that both the female and male group showed an increasing tendency in the all items, except the response of depression as age was increasing. 7. The responses of psychosomatic complaints by the length of services were that both the female and male group showed a tendency of increasing in physical symptoms as work years increased. 8. The responses of psychosomatic complaints were higher in unmarried group in the score of nervousness, aggressiveness, mental irritability and irregular life.

  • PDF

The distribution characteristics of airborne lead in the major monitoring locations in Korea (국내 주요지역의 대기 중 납성분에 대한 분포특성 조사)

  • Kim, K.H.;Jung, S.Y.
    • Journal of Environmental Policy
    • /
    • v.4 no.2
    • /
    • pp.83-101
    • /
    • 2005
  • Because of its strong potential for health hazards, the concentration levels of airborne lead (Pb) have been circumscribed by environmental laws in many countries. In this study, we made a comparative study on the environmental behavior of Pb for the acquisition of its distribution characteristics using data sets collected from major cities in Korea for a period of 6 years (1998 through 2003). According to this study, Pb concentration decreased slowly in most industrialized cities of Koreathroughout the whole study. period. In contrast, such temporal signals were not evident in data sets collected from residential, commercial, and grassland areas. Although seasonal patterns generally exhibited the occurrences of high Pb concentration during the spring, results appear to reflect the influence of Asian Dust (AD) in the springtime. The results of our study clearly indicate that Pb distribution is strongly influencedby source types in relation to their land use patterns. Comparison of our Pb data sets with that of other countries indicates that Pb concentration levels obtained from relatively cleaner districts of Korea are still significantly higher than other countries. The results of this analysis generally indicate that Pb concentrations in most areas are affected by the type and strength of man-made activities. Considering that most areas are affected by a variety of pollutants, continuous efforts are needed to control Pb concentrations in the atmosphere.

  • PDF