Study of the Possibility of Estimating the Setting Time and Early Aage Compressive Strength of Mortar Using D-type Durometer (D형 Durometer를 이용한 모르타르의 응결 및 초기 압축강도 추정가능성 평가)

  • Han, Soo-Hwan;Hoo, Yun-Yao;Lim, Gun-Su;Hyue, Seung-Yong;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.103-104
    • /
    • 2021
  • This study attempted to confirm the possibility of estimating condensation time and initial compressive strength with five types of estimation needles in the existing Durometer D type. In order to determine the surface finishing operation time and develop a method for estimating the initial age compression strength, an estimation needle capable of complexly measuring the estimation time and the initial age compression strength based on the Durometer D type was derived as 1.5, 2.0mm.

  • PDF

The Characteristics of the Change in dry Contraction Length of Dry Mortar for Each Cosmetic Period using an Improved Durometer (개량형 Durometer를 활용한 미장시기별 Dry Mortar의 건조수축 길이변화 특성)

  • Han, Soo-Hwan;Hyun, Seung-Yong;Hwang, Yin-seung;Yoon, Chi-Whan;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.190-191
    • /
    • 2021
  • This study is conducted to provide a method to estimate the setting time and early age compressive strength using D type durometer.Test results indicated that the use of D type Durometer attached with modified needle, which was designed to secure improved accuracy in setting and compressive strength, enables to estimate setting time and the compressive strength at early age.

  • PDF

ing Durometer D type Evaluation of the possibility of Estimatingon of Setting Time and InitialEarly aAge Compressive Strength Using Durometer D type Durometer (D형 Durometer를 이용한 콘크리트의 미장용 모르타르의 응결시간 및 초기재령 압축강도 추정)

  • Han, Soo-Hwan;Han, Jun-Hui;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.57-58
    • /
    • 2021
  • This study is conducted an experiment to unifyprovide a method to estimate the method of measuring the condensationsetting time and estimating the initialearly age compressive strength using the existingD type ddurometer. into a single device and to adopt the best estimation guidelines of the estimator. As a result of the experiment, Test results indicated that it is analyzed that the use of D type Durometer attached with modified needle, which was designed to secure improved accuracy in setting and compressive strength, enables to estimate it is possible to estimate the condensationsetting time of mortar and estimate the compressive strength ofat early age. the initial age when the estimation No. 2 is adopted for the Durometer D type.

  • PDF

Feasibility Study of Modified Durometer to Evaluate Setting Time of the Concrete (콘크리트의 응결시간 판정시 개량형 듀로미터의 사용 가능성 분석)

  • Han, Cheon-Goo;Han, Min-Cheol;Shin, Yong-Sub
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.5
    • /
    • pp.433-440
    • /
    • 2020
  • In this study, a new type of Durometer was invented by modifying the currently used Durometer with the hemisphere shaped needle to columnar shaped needle. The aim of the study is, hence, to provide the feasibility of the advanced Durometer for assessing setting time of the concrete. Generally, the finishing of concrete surface should be conducted to secure the smooth surface, improve the permeability, and prevent the plastic shrinkage cracking. Although this surface finishing work should be conducted during the plastic phase between initial and final setting, currently in practical situations, the timing of starting the finishing work was determined by the sense of the worker. To improve this situation, Kato Junji suggested to use the hemisphere and needle shaped Durometers to determine the initial and final setting time, respectively. However, in this case, there are difficulties of using two different Durometers and of occurring failure of the Durometer due to the intruded cement paste. To prove the feasibility of new typed Durometer, setting time and surface hardness were evaluated by applying for the concrete with various replacing ratios of fly-ash and coal gasification slag as an aggregate.

Setting Time Evaluation of High Flowable Ternary Concrete Mix Using Durometer (듀로미터를 이용한 3성분계 고유동 콘크리트의 응결시간 추정)

  • Han, Min-Cheol;Lee, yuk-Ju
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.33-38
    • /
    • 2020
  • The aim of the research is to evaluate the feasibility of durometer for assessing setting time of the concrete by comparing it with the currently used proctor penetration test method to improve the surface finishing timing determining method generally determined based on the experience of the worker. As a research result, the correlation between suggesting method using durometer with currently used proctor penetration test method was high enough. Hence, on the surface of the concrete, the initial setting time and the final setting time could be designated as 41 HD with C-type, and 11 HD with D-type, respectively. Therefore, the durometer can be used as a portable setting time evaluation device with the easiness of handling and measuring for determining concrete surface finishing timing quantitatively.

Estimation of Compressive Strength at Early Age of Hardened Concrete Using Rubber Hardness Meter (고무경도계를 활용한 경화 콘크리트의 초기재령 압축강도 추정)

  • Han, Soo-Hwan;Choi, Yoon-Ho;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.181-182
    • /
    • 2020
  • This study investigates the feasibility tp estimate the compressive strength at early age in hardened concrete by applying Durometer D type. The result of the experiment showed that the compressive strength reached 5MPa 6 hours, and 55 HD when the hardness was measured with the type D of the Duometer. Through this, it is expected that it will be possible to estimate the compressive strength of the initial age and measure it by the age of 28 when using the Durometer D type in the ready-mixed concrete, which will be applied in practice.

  • PDF

Estimation of Setting Time of Chlorine By-pass System Dust Mortar using Setting Time Estimation (현장용 응결시간추정계를 이용한 고염화물 모르타르의 응결시간 추정)

  • Lee, Hyuk-Ju;Han, Jun-Hui;Hyun, Seong Yong;Shin, Yong-Seop;Lee, Jun-Seok;Han, Min-Choel
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.6-7
    • /
    • 2018
  • In the previous study, durometer, namely rubber hardness tester Was used to confirm the possibility of using the setting time of concrete for determination. in this study, the possibility of using condensation time judgment condensation estimation system by comparing the measuring station setting estimation system Measuring needle of the proctor penetration resistance tester by newly making a measurement needle and refining the coagulation estimation system Want to make sure. As a result of this study, it was possible to use one condensation estimation system showing similar correlation between the two types of durometer showing high correlation with the penetration resistance value of proctor testers, It is considered to be fruitful to use the dew condensation estimation system for determining the setting time.

  • PDF

The Measurement of Korean Face Skin Rigidity for a Robotic Headform of Respiratory Protective Device Testing (호흡보호구 평가용 얼굴 로봇을 위한 한국인 얼굴 피부의 경도 측정)

  • Eun-Jin Jeon;Young-jae Jung;Ah-lam Lee;Hee-Eun Kim;Hee-Cheon You
    • Fashion & Textile Research Journal
    • /
    • v.25 no.2
    • /
    • pp.248-254
    • /
    • 2023
  • This study aims to measure the skin rigidity of different facial areas among Koreans and propose guidelines for each area's skin rigidity that can be applied with a facial robot for testing respiratory protective devices. The facial skin rigidity of 40 participants, which included 20 men and 20 women, aged 20 to 50, was analyzed. The rigidity measurement was conducted in 13 facial areas, including six areas in contact with the mask and seven non-contact areas, by referring to the facial measurement guidelines of Size Korea. The facial rigidity was measured using the Durometer RX-1600-OO while in a supine position. The measurement procedure involved contacting the durometer vertically with the reference point, repeating the measurement of the same area five times, and using the average of three values whose variability was between 0.4 and 4.2 Shore OO. The rigidity data analysis used precision analysis, descriptive statistics analysis, and mixed-effect ANOVA. The analysis confirmed the rigidity of the 13 measurement areas, with the highest rigidity of the face being at the nose and forehead points, with values of 51.2 and 50.8, respectively, and the lowest rigidity being at the chin and center of the cheek points, with values of 19.2 and 20.7, respectively. Significant differences between gender groups were observed in four areas: the tip of the nose, the point below the chin, the area below the lower jaw, and the inner concha.

One-way ANOVA Analysis to Verify the Effect of Hybrid Strength Estimators by Number of Measurements (일원분석을 통한 하이브리드 추정계의 측정횟수별 영향검증)

  • Han, Soo-Hwan;Hu, Yun-Yao;Kim, Su-Ho;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.37-38
    • /
    • 2022
  • This study is attempted to propose an appropriate number of measurements by checking and statistically analyzing the change in hardness according to the number of measurements. As a result, there was no significant difference between the 20th and 30th data, and in the 10th case, the effect on errors occurring during measurement was found to be dominant. Therefore, as the number of measurements, proposing 20 times in consideration of the convenience of use. In addition, in order to minimize the effect on the measurement error, it is proposed to remeasure the surface mane of the measurement surface and the test value in which the error occurs on the average of the test values.

  • PDF

Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

  • Pahuja, Rasleen Kaur;Garg, Sandeep;Bansal, Sanjay;Dang, Rajat Harvinder
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.270-277
    • /
    • 2013
  • PURPOSE. This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS. Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of $15mm{\times}10mm$ dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS. Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION. Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.