• Title/Summary/Keyword: Durability Test

Search Result 2,086, Processing Time 0.026 seconds

Drying Shrinkage Properties of Latex Modified Concrete with Ordinary Cement and Rapid-Setting Cement (초속경 및 일반시멘트를 이용한 라텍스개질 콘크리트의 건조수축 특성)

  • Yun, Kyong-Ku;Jeong, Won-Kyong;Kim, Sung-Hwan;Lee, Joo-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.95-101
    • /
    • 2003
  • Drying shrinkage cracking which may be caused by the relatively large specific surface is a matter of grave concern for latex modified concrete(LMC) overlay and rapid-setting cement latex modified concrete(RSLMC) overlay. LMC and RSLMC were studied for field applications very actively in terms of strength and durability in Korea. However, there were no considerations in drying shrinkage. Therefore, the purpose of this dissertation was to study the drying shrinkage properties of LMC and RSLMC with the main experimental variables such as cement types(ordinary portland cement, rapid setting cement), latex contents(0, 5, 10, 15, 20%) and curing days at a same controlled environment of 60% of relative humidity and $20^{\circ}C$ of temperature. The drying shrinkage for specimens was measured with a digital dial gauge of Demec. The test results showed that the drying shrinkage of LMC and RSLMC were considerably lower than that of OPC and RSC, respectively. This might be attributed to the interlocking of hydrated cement and aggregates by a film of latex particles, water retention due to hydrophobic, and colloidal properties of the latexes resulting in reduced water evaporation.

Fatigue Behavior of Prestressed Concrete Beams Using FRP Tendons (FRP 긴장재를 이용한 프리스트레스트 콘크리트 보의 피로 거동)

  • Kim, Kyoung-Nam;Park, Sang-Yeol;Kim, Chang-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.135-144
    • /
    • 2011
  • Recently, researches about fiber reinforced polymer (FRP) which has excellent durability, corrosion resistance, and tensile strength as a substitution material to steel tendon have been actively pursued. This study is performed to examine FRP tendon used prestressed beam's safety under service load. The specimen was a prestressed concrete beam with internal bonded FRP tendon. In order to compare the member fatigue capacity, a control specimen of a prestressed concrete beam with ordinary steel tendon was tested. A fatigue load was applied at a load range of 60%, 70%, and 80% of the 40% ultimate load, which was obtained though a static test. The fatigue load was applied as a 1~3 Hz sine wave with 4 point loading setup. Fatigue load with maximum 1 million cycles was applied. The specimen applied with a load ranging between 40~60% did not show a fatigue failure until 1 million cycles. However, it was found that horizontal cracks in the direction of tendons were found and bond force between the tendon and concrete was degraded as the load cycles increased. This fatigue study showed that the prestressed concrete beam using FRP tendon was safe under a fatigue load within a service load range. Fatigue strength of the specimen with FRP and steel tendon after 1 million cycles was 69.2% and 59.8% of the prestressed concrete beam's static strength, respectively.

Evaluation for Applicability of Reinforced Concrete Structure with Domestic Pond Ash (국산 매립회 골재를 사용한 콘크리트 구조물의 적용성 평가)

  • Lee, Bong-Chun;Jung, Sang-Hwa;Chae, Sung-Tae;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.541-550
    • /
    • 2011
  • Many researches have been performed on concrete with fly ash and bottom ash. However researches on concrete with pond ash (PA) and its application to RC (Reinforced Concrete) structure are limitedly carried out. This paper presents an applicability of PA concrete in construction of real size structure. Referring to the previous study, 2 domestic PA samples with normal performance are selected and 2 replacement ratios (25% and 50%) to fine aggregate are considered for 5 PA concrete structures consisting of column, slab, and wall. In order to evaluate the property of fresh concrete, several tests including air content, slump, and setting time are performed. Using cored out samples from hardened PA concrete structure, tests for strength, resistance to carbonation and chloride penetration are carried out and compared with control samples. Additionally, tests for rebound hardness, drying shrinkage, and hydration heat are performed for PA concrete structure. The test results showed that PA concrete has reasonable strength and durability performances compared to those of normal concrete. Therefore, its potential application to RC structure is promising. The PA aggregate can be more actively used for RC structures with better quality control for content of fly ash, bottom ash, and unburned carbon.

Case Study of Improvement against Leakage of a Sea Dike under Construction (해안제방 시공 중 해수유입에 대한 차수보강 사례분석)

  • Han, Sang-Hyun;Yea, Geu-Guwen;Kim, Hong-Yeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 2015
  • In this study, the causes and countermeasures for the leakage of a sea dyke under construction are analyzed. In general, the seabed ground is clearly divided from the embankment but a lot of parts show abnormal zones with low resistivity from the results of electric resistivity survey. Hence the causes of the leakage are considered as following: three-dimensional shear strain behavior, irregular compulsory replacement of the soft seabed ground with low strength and quality deterioration of the waterproof sheets during the closing process. The improvement method is determined by considering the constructability in the seawater and its velocity condition, durability, economic feasibility, similar application cases and so on. Consequently, a combination of low slump mortar and slurry grouting and injection method is selected as an optimum combination. Mixing ratio and improvement pattern are determined after drilling investigation and pilot test. The improvement boundary is separated into general and intense leakage area. The construction is performed with each pattern and the improvement effects are confirmed. The confirmed effects with various tests after completion show tolerable ranges for all of the established standards. Finally, various issues such as prediction of length of the waterproof sheet, installation of it against seawater velocity, etc. should be considered when sea dykes are designed or executed around the western sea which has high tide difference.

A Study on the Base Properties of Nickel Type-Antifungal Agent for Reinforced Concrete Hume Pipe Lining (철근콘크리트흄관 라이닝용 니켈계 방균제의 기초적 특성 연구)

  • Jo, Young-Kug
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.41-47
    • /
    • 2010
  • It has been continuously noted that many sewage treatment concrete structures have deteriorated due to sulfur-oxidizing bacteria. There have been many reports on approaches to protecting concrete from this bacteria corrosion. The purpose of this study is to evaluate the inhibition of growth of a sulfur-oxidizing bacterium by a antifungal agent such as $NiSO_4{\cdot}6H_2O$, and the characteristics of polymer cement mortar using nickel type antifungal agent. First, we developed antifungal agents using metal nickel and $NiSO_4{\cdot}6H_2O$ to inhibit the growth of thiobacillus novellus, which is the sulfur-oxidizing bacteria in concrete. Then, ordinary cement mortar and polymer cement mortar using nickel type antifungal agent with various polymer-cement ratios, and antifungal agent content were prepared, and were tested for the antifungal adding effect, compressive and flexural strengths, expansion and leaching of nickel ion. From the test results, it was confirmed that the adding of an antifungal agent has an inhibition effect on the growth of sulfur-oxidizing bacteria at antifungal agent contents of 20 mM or more. In addition, the strengths and expansion of polymer cement mortars are not significantly changed by the addition of an antifungal agent. Therefore, the nickel-type antifungal agent developed in this study can be used to improve the durability of reinforced concrete hume pipe in the construction industry.

Development of a Design System for Multi-Stage Gear Drives (2nd Report: Development of a Generalized New Design Algorithm) (다단 치차장치 설계 시스템 개발에 관한 연구(제 2보: 일반화된 신설계 알고리즘의 개발))

  • Chong, Tae-Hyong;Bae, In-Ho;Park, Gyung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.192-199
    • /
    • 2000
  • The design of multi-stage gear drives is a time-consuming process because it includes more complicated problems, which are not considered in the design of single-stage gear drives. The designer has no determine the number of reduction stages and the gear ratios of each reduction stage. In addition, the design problems include not only dimensional design but also configuration design of gear drive elements. There is no definite rule or principle for these types of design problems. Thus the design practices largely depend on the sense and the experiences of the designer, and consequently result in undesirable design solution. A new and generalized design algorithm has been proposed to support the designer at the preliminary phase of the design of multi-stage gear drives. The proposed design algorithm automates the design process by integrating the dimensional design and the configuration design process. The algorithm consists of four steps. In the first step, the user determines the number of reduction stages. In the second step, gear ratios of every stage are chosen using the random search method. The values of the basic design parameters of a gear are chose in the third step by using the generate and test method. Then the values of the dimensions, such as pitch diameter, outer diameter and face width, are calculated for the configuration design in the next step. The strength and durability of each gear is guaranteed by the bending strength and the pitting resistance rating practices by using AGMA rating formulas. In the final step, the configuration design is carried out using simulated annealing algorithm. The positions of gears and shafts are determined to minimize the geometrical volume (size) of a gearbox while avoiding interferences between them. These steps are carried out iteratively until a desirable solution is acquired. The proposed design algorithm is applied to the preliminary design of four-stage gear drives in order to validate the availability. The design solution has considerably good results in both aspects of the dimensional and the configuration design.

  • PDF

Permeability and Freeze-Thaw Resistance of Latex Modified Concrete (라텍스 개질 콘크리트의 투수성 및 동결융해 저항 특성)

  • 김기헌;이종명;홍창우;윤경구
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.484-490
    • /
    • 2001
  • This study focused on the investigation of durability of latex modified concrete in the points of chloride ion permeability and freeze-thaw resistance as latex content variated such as 5%, 10%, 15% and 20%. When latex was mixed in concrete and cured, the concrete consisted of hydrated cement and aggregate interconnected by a film of latex particles. An increasing the amount of latex produced concrete with increased flexural strength, but with slightly lower compressive strength. The increase in flexural strength might be attributed to the latex films between the hydrated cement and aggregates, and the decrease in compressive strength to the flexibility of the latex component named by Butadiene. The rapid chloride permeability test was used to evaluate the relative permeability of latex-modified concretes and conventional concretes. The results showed that the permeability of latex-modified concretes was considerably lower than conventional concretes tested, which might be due to the latex filled in voids and interconnections of hydrated cement and aggregates by a film of latex particles. The freeze-thaw resistance of LMC was quite good comparing to conventional concrete. Air entraining agent has been used in conventional concrete to improve the freeze/thaw resistance, but latex modified concrete does not need additional air entraining agent for freeze-thaw resistance provided adequate cure occurs.

Investigation and Evaluation of Algae Removal Technologies Applied in Domestic Rivers and Lakes (국내 하천/호수에 적용된 조류저감기술의 조사 및 평가)

  • Byeon, Kyu Deok;Kim, Ga Young;Lee, Inju;Lee, Saeromi;Park, Jaeroh;Hwang, Taemun;Joo, Jin Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.387-394
    • /
    • 2016
  • Commercial 28 algae removal technologies that have been applied in domestic rivers and lakes with green tide were investigated, analyzed and classified. The classification of algae removal technologies was based on the three criteria (i.e., principle, flow rate of water body, and application period). Also, algae removal technologies were evaluated in terms of cost effectiveness, field applicability, effect durability, and eco friendliness. From the analysis results, technologies using physical, chemical, biological, and convergent controls were 32.2%, 25%, 21.4%, and 21.4%, respectively. The 75% of technologies have been applied to stagnant water body (${\leq}0.2m/s$). Also, algae harvesting ship with dissolved air flotation, conveyor belt and filtration processes and natural floating coagulant were found to have better field applicability, compared to other technologies. However, proper algae removal technology in specific rivers and lakes should be chosen after the evaluation of long-term pilot scale field test. Also, development of energy and resource recovery technologies from algae biomass is warranted.

An Experimental Study on the Behavior of Curved Panel Parts Using Composite Materials (복합소재를 활용한 곡면 패널의 부재단위 성능 평가)

  • Park, Hee Beom;Park, Jong-Sup;Kang, Jae-Yoon;Jung, Woo-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.474-480
    • /
    • 2018
  • FRP is a new material that is lightweight, has high strength and high durability, and is emerging as a third construction material in many countries. The composite material panel targeted in this study was a curved member and is the most frequently used arch-shaped member of a structures, such as tunnels. Composite curved panels can be produced in high quality and large quantities through automation operations. On the other hand, the frequency of application is low, and the design criteria and experimental data are lacking. Therefore, this study examined the mechanical performance of the member unit first to verify its performance as structural members of the FRP curved panel. For this purpose, tensile, compression, and connection performance tests were carried out. The tensile tests showed greater tensile strength of specimens with larger curvature, and the compression tests showed that the composite section of a composite material has greater compressive strength than the concrete section. Finally, the test of the performance of the connection showed that the attachment performance of the connection was more than equal to that of the FRP composite material panel.

Comparative analysis of cutter acting forces and axial stresses of single and double disc cutters by linear cutting tests (선형절삭시험에 의한 더블디스크커터와 싱글디스크커터의 커터 작용력과 축응력에 대한 실험적 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Park, Young-Taek;Lee, Gyu-Phil;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.181-191
    • /
    • 2014
  • This study aims to evaluate cutter acting forces as well as axial stresses and torques in the shaft of two kinds of disc cutters including a single disc cutter and a double disc cutter with the same cutter ring geometry in a series of linear cutting tests. From the tests, the mean values of normal forces and rolling forces acting on the double disc cutter were approximately twice as high as those from the single disc cutter. Similarly, the mean values of axial stresses in the shaft of the double disc cutter were also twice as high as those from the single disc cutter even though the comparisons of torques from two kinds of disc cutters were insignificant since they showed very low values. However, it is necessary to take the durability of a tapered roller bearing used for the double disc cutter into high consideration since the average normal force from the double disc cutter exceeds the allowable force for a disc cutter with the diameter of 432 mm (17 inches). Finally, there is no practical problem in terms of axial stresses in the shaft of the double disc cutter since they are much lower than the yielding stress of the cutter shaft material, even though the axial stresses in the shaft of the double disc cutter are approximately twice as high as those from the single disc cutter.