• Title/Summary/Keyword: Durability Test

Search Result 2,080, Processing Time 0.026 seconds

Airframe Durability Certification for Export Basic Trainer (수출형 기본 훈련기에 대한 기체구조물 내구성 입증)

  • Park, Taegyu;Park, Jeongkyu;Moon, Changoh
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.19-24
    • /
    • 2015
  • Export basic trainer was designed to add armed configuration required by customer. Design configuration of main wing was changed to satisfy changed internal load caused by armed configuration. It was verified that design changed main wing airframe of export basic trainer satisfy the requirement through the structural detail analysis, structural ground test and flight test. This paper presents the durability test procensure and test result for the main wing of export basic trainer.

The Evaluation of Reliability for the High Pressure Hydrogen Storage System of Fuel Cell Vehicle (연료전지자동차의 고압수소저장시스템 신뢰성 평가)

  • Jang, Gyu-Jin;Choi, Young-Min;Ahn, Byung-Ki;Lim, Tae-Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.4
    • /
    • pp.266-275
    • /
    • 2008
  • The performance improvement of each part for durability, safety and cost of high pressure storage system for fuel cell vehicle has been focused so far. However, for the mass production of fuel cell vehicle, it is necessary to evaluate durability and safety in system module and vehicle level. The test procedure to evaluate vibration and collision safety of high pressure hydrogen storage system for the fuel cell vehicle is established and its reliability is verified.

Study on Vibration Fatigue Analysis of Automotive Battery Supporter (자동차 배터리 지지 구조의 진동 피로 해석에 대한 연구)

  • Ah, Sang Ho
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.4
    • /
    • pp.22-27
    • /
    • 2019
  • In this paper, the vibration load and analysis results for automotive battery supporter were performed to provide efficient vibration tolerance performance prediction methods for single-product vibration tolerance testing, and the major influencing factors and considerations for setting up single-unit vibration tolerance tests were reviewed. A common applicable standard load was applied to efficiently predict the performance of single-unit vibrations through the frequency response analysis technique. The results similar to test results can be predicted by checking vulnerable parts of the vehicle components for vibration loads and applying scale factor to standard loads. In addition, it was confirmed that the test conditions with a frequency generating the same durability severity as the endurance test are needed for accurate prediction of the durability of the single-unit vibration tolerance test conditions, and the acceleration and frequency with the conditions that there is no significant nonlinear phenomena in the vibration system are established during the single-unit vibration tolerance test conditions.

Accelerated Test Program for Durability Characteristics of GFRP Rebars (내구특성 파악을 위한 GFRP 보강근의 촉진실험 연구)

  • Kim, Hyeong-Yeol;You, Young-Jun;Park, Young-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.157-164
    • /
    • 2006
  • This paper presents the durability characteristics of commercially available CFRP rebars under various environmental conditions. Two types of GFRP rebars were tested by using an accelerated aging method. A total of 264 rebar specimens were conditioned up to 132 days in the moisture, chloride. alkaline, and freeze-thaw environmental conditions. The durability characteristics of conditioned rebars were obtained by comparing the tensile strength, horizontal shear strength, and elastic modulus between the unconditioned and conditioned GFRP rebars. The test results indicated that the mechanical properties of GFRP were significantly reduced after conditioning. Long-term degradation of GFRP rebars was also estimated using the results of a short-term durability test.

Experimental Analysis of GDL Degradation in PEM Fuel Cell (고분자전해질형 연료전지 가스확산층의 내구 성능 저하에 관한 실험적 분석)

  • Ha, Tae-Hun;Park, Jae-Man;Cho, Jun-Hyun;Min, Kyoung-Doug;Lee, Eun-Suk;Jung, Ji-Young;Kim, Do-Hun;Jin, Yong-Won;Lee, Dae-Han
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.132-132
    • /
    • 2009
  • To achieve the commercialization of PEM fuel cell, the durability problem must be solved. Recently, many researchers have focused on this durability problem and degradation studies about membrane and electrode have been reported. But durability characteristics of gas diffusion layer is not much reported yet. Durability of GDL is very important to maintain the performance of PEM fuel cell because the main function of GDL is a path of fuel and water and the GDL degradation causes the loss of the GDL function. In this study, the degradation of GDL, especially, the mechanical degradation process was investigated with the leaching test. The effect of water dissolution was observed through the test and the amount of GDL degradation was measured with various measurement methods such as weight measurement, static contact angle measurement, scanning electron microscope. After 2,000 hours test, the GDL showed structural damage and loss of hydrophobicity.

  • PDF

A Study on Durability Performance Estimation for Development of Chassis Corner Module (샤시코너모듈 개발을 위한 부품의 내구 성능 예측에 대한 연구)

  • Choi Sungjin;Park Jungwon;Jeon Kwangki;Yoo Youngmyun;Choi Gyoojae;Park Taewon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.159-166
    • /
    • 2006
  • Chassis system has a large influence on ride quality, stability and NVH performance of a car. To improve the performance and reduce cost, the development of chassis modular assemblies is emphasized. To develop chassis corner modules, it is necessary to predict the performance of full vehicle motion such as ride, handling performance, NVH characteristics and durability of modules. In this paper, full vehicle test is performed to acquire the road load data of chassis corner module of passenger car. 3-axis simulator modeling are carried out to simulate reaction force analysis and fatigue analysis of new developed modules. Also, real simulator tests to validate performance of new developed modules are performed. We had developed the accelerated durability test procedure of KATECH PG and it is used to test chassis corner modules at laboratory and simulate durability performance. All these results have been provided to module and parts company and make an important role to develop chassis corner modules.

An Experimental Study on the Leakage Characteristics and Durability Evaluation of an LPLi Injector (LPLi 인젝터의 누설특성 및 내구평가에 관한 실험적 연구)

  • Choi, Young;Kim, Chang-Up;Oh, Seung-Mook;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.12 no.4
    • /
    • pp.204-210
    • /
    • 2007
  • The worldwide energy problem and global warming cause the need of alternative fuels which feature low carbon-dioxide emission and another energy source. Liquefied Petroleum Gas (LPG) is one of the alternative fuels widely used as domestic and transportational fuel. The third generation LPLi fuel supply system has merits in the increase of engine power and low emissions. The injectors used in LPLi system should overcome a leakage problem and satisfy the durability conditions. Therefore, 1000 hour durability test of the injectors was carried out throughout this research. First, the spray pattern and the penetration length of the selected injectors is graphically shown. Next, the leakage amount with respect to the injection cycle is introduced. Finally, the shapes of nozzle holder and nozzle tip after durability test was investigated by analyzing the microscopic image of the injector tip. The variation in the shape of nozzle tip mainly due to the residue of rubber materials is found to be the reason for leakage.

  • PDF

A Study on the Plasma Nitriding Application for the Durability Improvement of the Exhaust Decoupler (배기계 디커플러의 내구 향상을 위한 플라즈마 질화에 관한 연구)

  • Hur, Deog-Jae;Kim, Sang-Sik;Chung, Tae-Jin;Kim, Do-Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.157-163
    • /
    • 2006
  • This paper described the process of improving durability performance of the exhaust decoupler by the plasma nitriding. The properties of plasma nitriding treatment of AIS1304 stainless steel were tested using specimens before applying plasma nitriding to a mesh ring. In order to analyses the effect of plasma nitriding treatment on the mechanical properties, SEM(Scanning Electron Microscopes), roughness and hardness tester were used. Based on specimen plasma nitriding, we could find appropriate condition for application to the mesh ring of decoupler. To confirm the improved durability performance, we compared the number of cycles, which reaches to fracture, of the nitrided decoupler and that of the unnitrided decoupler by the bending cyclic test. In this test, the durability and wear resistance of the mesh ring are significantly improved by plasma nitriding treatment.

Vibration Reduction of Pipe Line in Air-conditioner for Railway Vehicle (철도차량용 냉방기 배관계의 진동저감 연구)

  • You, Won-Hee;Jung, Yong-Ho;Koo, Jeong-Seo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.925-931
    • /
    • 2012
  • The air-conditioner for railway vehicle should have vibration durability in order to operate normally in vehicle running situation. KS R 9144(vibration test methods for railway vehicle parts) is used to verify the vibration durability. The specifications of compressor, condenser and evaporator for air-conditioner in railway vehicle are standardized, but the shape and structure of pipe lines are not specified. Because the air-conditioner handler produces the pipe line arbitrarily, sometimes the pipe line is broken during the vibration durability test. In this research the cause identification and solution of pipe line breaking problem in during the vibration durability test were studied for air-conditioner of railway vehicle(diesel multiple unit). It was found that the natural frequency of pipe line is related to the pipe line breaking by experiment. A new pipe line shape was introduced by using FEA in order to avoid the resonance. The prototype new pipe line was applied to air-conditioner and the natural frequency was measured by experiment in order to verify the resonance avoidance. The vibration reduction of air-conditioner with new pipe line was reviewed by comparing to the air-conditioner with original one.

Mechanical and Durability Characteristics of Latex-Modified Concrete Using Ultra Rapid Hardening Cement (초속경 시멘트를 이용한 라텍스 개질 콘크리트의 역학성능과 내구성능)

  • Park, Sang-Hyun;Jung, Si-young;Kim, Hyun-yu;Choi, Kyoung-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.153-160
    • /
    • 2019
  • The purpose of this study was to investigate the mechanical and durability characteristics of latex-modified concrete using ultra rapid hardening cement : four types of mechanical tests including compressive strength, modulus of elasticity, flexural strength and bond strength were performed; and seven types of durability tests including resistance of concrete to chloride ion penetration, freeze-thaw resistance, scaling resistance, coefficient of thermal expansion, cracking tendency, abrasion resistance and drying shrinkage were performed. Required material performance of each test was determined in accordance with the Korea specification for repair of concrete and pavement repairing materials. The test results satisfied the required material performances, and presented a good mechanical and durability characteristics. In particularly, the materials showed early development of compressive strength, flexural strength and bond strength at 3 and 4 hours after curing. SEM photos were also taken to investigate the micro structures of the materials after chloride ion penetration test.