• Title/Summary/Keyword: Durability Improvement

Search Result 598, Processing Time 0.026 seconds

Development of Inorganic Fire Protection Materials for High Strength Concrete (구조체 보호를 위한 고내화성 마감재 적용에 관한 실험적 연구)

  • Jung, Suk-Jo;Song, Hun;Kwon, Choon-Woo;Kim, Young-Yup;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.885-888
    • /
    • 2006
  • Nowaday, High strength concrete(HSC) has been mainly used in high rise building. HSC have superior property as well as improvement in durability compared with ordinary strength concrete. In spite of durability of HSC, explosive spalling in concrete front surface near the source of fire occurs serious problem in structural safety. Thus, this study is concerned with experimentally investigation fire resistance of the inorganic fire protection materials at high temperatures up to $800^{\circ}C$. From the test result, developed inorganic binder becomes general that with rising temperature the compressive strength of the material increases in tendency. Therefore, the results indicate that it is possible to fireproof panels, fire protection of materials, etc.

  • PDF

A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure (콘크리트 BOX 구조물의 수화열에 의한 온도균열제어 대책)

  • Kim, Eun-Kyum;Jeon, Chan-Ki;Jeon, Joong-Kyu;Bae, Sang-Il
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.705-708
    • /
    • 2006
  • The bigger of concrete structures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, which is located in chloride attack region, the use of blended cement, the temperature of air and concrete, was considered and analysed by a three dimensional finite element method.

  • PDF

Surface Layer Change of Concrete with Concrete Impregnant (침투성 함침제에 따른 콘크리트 표층부의 개질특성)

  • Song, Hun;Shin, Hyeong-UK;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.200-201
    • /
    • 2013
  • This study is interested in manufacturing the concrete surface impregnants including tetra ethyl ortho silicate, alkali silicate for the repair of the exposed concrete and the color concrete requiring the advanced function in view of the concrete appearance. The surface layer change and porosity properties was tested for the review of application. The result of this study show that the effective silicate are tetra ethyl ortho silicate and alkali silicate t. The adhesion in tension is slightly increased but the reinforcement of concrete substrate is slight. So, the concrete impregnant of this study is more desirable for the improvement of durability rather than the reinforcement.

  • PDF

An Experimental Study on the Spalling Properties of Ultra High Strength Concrete with PP Fiber (초고강도 콘크리트의 섬유혼입률에 따른 폭렬특성에 관한 실험적 연구)

  • Lee, Tae-Gyu
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.65-68
    • /
    • 2011
  • High strength concrete(HSC) has been mainly used in large SOC structures. HSC have superior property as well as improvement in durability compared with normal strength concrete. In spite of durability of HSC, explosive spalling in concrete front surface near the source of fire occurs serious problem in structural safety. It is reported that spalling is caused by the vapor pressure under fire and polypropylene(PP) fiber has an important role in protecting from spalling. The spalling properties of ultra high strength concrete specimens with various contents of PP fiber were investigated in this study. In results, the content of PP fiber for spalling protection increases over 0.2 vol.% as the concrete strength increases to 120 MPa.

Combustion Characteristics of Municipal Wastes in Pyrolysis Incinerator (열분해 소각시설에서의 일반폐기물의 연소특성)

  • Park, Myung-Ho
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.149-156
    • /
    • 2011
  • In case of domestic pyrolysis dry distillation gassification technology, it stays at the stage of its early introduction and development. Moreover, the companies possessed of this technology are limited to Japan and some countries in Europe, and domestic operative performance of this system is nominal, so there exist a lot of difficulties in securing its basic data. In addition, considering its operation and management, there happens a corrosion of metals by the production of corrosive gases in time of combustion of waste, and there arise a problem of occurrence of low temperature corrosion on exterior casing or gas ducts of a combustion chamber due to the high temperature corrosion around the burner of an incinerator, lowering the durability of an incinerator. Therefore, this study looked at the problems arising in time of incineration by understanding the characteristics of the pyrolysis dry distillation gassification incinerating facility, and did research on the improvement plan for durability of an incinerator for more economic, efficient waste incineration.

Performance evaluation of binary blends of Portland cement and fly ash with complex admixture for durable concrete structures

  • Yang, Dingyi;Sun, Wei;Tan, Yongquan
    • Computers and Concrete
    • /
    • v.2 no.5
    • /
    • pp.381-388
    • /
    • 2005
  • This paper presents the results of a study on binary blends of Portland cement and fly ash with complex admixture used for the concrete structures to meet specific performance objectives in east coastal area of China. The concretes were evaluated for workability, strength, water permeability, drying shrinkage, sulfate resistance and electrical resistance. Environmental Scanning Electron Microscopy (ESEM) was used to examine the microstructure of concrete made by complex admixture compared with control batches without complex admixture. The combined efforts of fly ash and complex admixture led to an improvement in the workability, strength and durability.

Treatment and Characterization of Polyethylene Terephthalate Fibers with Silicone Rubber Adhesive for Heat-Resistant Adhesion (실리콘 고무와 내열접착 향상을 위한 Polyethylene Terephthalate 섬유 접착층의 제조 및 특성)

  • Kim, Jihyo;Lee, Sangoh;Lee, Jaewoong
    • Textile Coloration and Finishing
    • /
    • v.31 no.2
    • /
    • pp.107-117
    • /
    • 2019
  • In case of pure rubber materials, the initial quality of the rubber materials would be excellent, however, the durability against external impact might be poor. In order to overcome the relatively low durability, textile cord could be employed with silicone rubber. We have studied the improvement of heat-resistant adhesion properties of silicone adhesives between silicone rubber and PET fibers by applying various conditions including dip solution recipe. The silicone rubber used was a platinum catalyst curing type and platinum catalyst type silicone adhesive was used as an adhesive to obtain an optimum adhesive force. Furthermore, the bonding mechanism between silicone and PET fiber was established.

Performance Improvement and Durability Evaluation of Shotcrete for Permanent Tunnel Support (터널 영구 지보재로서의 숏크리트 고성능화 및 내구성 평가에 관한 연구)

  • Lee, Sang-Pil;Ryu, Jong-Hyun;Lee, Sang-Don;Jeon, Seok-Won;Lee, Chung-In
    • Tunnel and Underground Space
    • /
    • v.17 no.4
    • /
    • pp.266-284
    • /
    • 2007
  • Recently, many efforts have been made to construct the first unlined tunnel, without in-situ concrete lining, in Korea. However, the lack of reliability in the performance of shotcrete as permanent tunnel support prevented from its realization. Shotcrete has been regarded to have significant problems in field application and long term performance because of unsatisfactory strength level and durability compared to those of European countries. In this study, the high strength shotcrete satisfying compressive strength over 40 MPa and flexural strength over 4.5 MPa was developed from optimized mix design. The type of accelerators and the amount of silica fume were selected as the main factors in mixing process and the analyses were carried out up to the elapsed time of 2 years. In order to evaluate the short term durability of shotcrete, an array of laboratory test consisting of freeze-thaw, carbonation chloride penetration and permeability test was performed. For long-term durability tests, specimens have been put in an operated highway tunnel to expose them to the similar environment when they are actually used as an unlined tunnel support. From the strength and durability tests, it was found that only alkali-free based accelerator satisfied the target strength of this study and also, the developed shotcrete showed very high performance in its durability.

Statistical Analysis for Improving Durability of Porous Asphalt Mixtures (다공성 아스팔트혼합물의 내구성 향상을 위한 통계적 분석의 활용)

  • Yoo, In-Kyoon;Lee, Su-Hyung;Han, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.283-290
    • /
    • 2020
  • Porous asphalt pavement is used widely in advanced countries to reduce traffic accidents and noise. On the other hand, it is not applied widely in Korea due to concerns about its durability. This study aims to find a statistical method to improve the durability of porous asphalt pavement. A Cantabro test was selected to test the durability. The Cantabro test was performed on an asphalt mixture made of a binder and aggregate. This test was repeated three times for each of the four groups to obtain the Cantabro loss rate. The average values of each of the four groups satisfied all the reference values. In addition, through an analysis of variance (ANOVA), it was possible to quantitatively classify test groups with differences in durability, thereby finding problems and improving the durability. Furthermore, the Pay Factor method can lead to voluntary improvements in quality, and the Pay factor can be calculated through statistical analysis of limited data. Through the Pay factor, it is possible to induce definite quality improvement of the contractor and continuously improve the durability of the porous asphalt mixture by evaluating the adequacy of the quality standard.

Freeze and Thaw Durability of Concrete Using Recycled Aggregates (재생골재를 사용한 콘크리트의 동결융해 저항성)

  • 문대중;팽우선;문한영
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.307-314
    • /
    • 2002
  • Utilization of demolished-concrete as recycled aggregate has been researched for the purpose of substituting for insufficient natural aggregate, saving resources and protecting environment. There, however, are some Problems not only the large difference of dualities in recycled aggregates but also a little deterioration of mechanical properties in recycled aggregate concrete in comparison with that of natural aggregate concrete. In this study, the test results of freez and thaw durability of concrete with demolished-concrete recycled aggregate(DRA) arc as follows. Improvement of crushing process is an important assignment because that adhered mortar on source-concrete recycled aggregate(SRA) and DRA highly affects thc qualifies of recycled aggregate. The compressive strength of recycled aggregate concrete was not highly different in comparison with that of control concrete. But the resistance to penetration of Cl in recycled aggregate concrete was shown smaller than that of control concrete because of adhered mortar on recycled aggregate. The resistance to frcezing and thawing of recycled aggregate concrete was highly different due to adhered mortar on recycled aggregate, and durability factor of concrete with NA-SRA and DRA was more decreased than that of control concrete. On the other hand, durability factor of concrete with AA-SRA was larger than that of control concrete. It, therefore, is necessarily required that recycled aggregate including adequate entrained air should be used for satisfying the freez and thaw durability of recycled aggregate concrete.