• 제목/요약/키워드: Ductility Factor

검색결과 270건 처리시간 0.024초

Design Equation for Punching Shear Capacity of SFRC Slabs

  • Higashiyama, Hiroshi;Ota, Akari;Mizukoshi, Mutsumi
    • International Journal of Concrete Structures and Materials
    • /
    • 제5권1호
    • /
    • pp.35-42
    • /
    • 2011
  • In this paper, a design equation for the punching shear capacity of steel fiber reinforced concrete (SFRC) slabs is proposed based on the Japan Society of Civil Engineers (JSCE) standard specifications. Addition of steel fibers into concrete improves mechanical behavior, ductility, and fatigue strength of concrete. Previous studies have demonstrated the effectiveness of fiber reinforcement in improving the shear behavior of reinforced concrete slabs. In this study, twelve SFRC slabs using hooked-ends type steel fibers are tested with varying fiber dosage, slab thickness, steel reinforcement ratio, and compressive strength. Furthermore, test data conducted by earlier researchers are involved to verify the proposed design equation. The proposed design equation addresses the fiber pull-out strength and the critical shear perimeter changed by the fiber factor. Consequently, it is confirmed that the proposed design equation can predict the punching shear capacity of SFRC slabs with an applicable accuracy.

기둥-보 휨강도비와 단위하중법을 이용한 철골모멘트골조의 강성설계기법 (Drift Design Method of Steel Moment Frames by using Column-Beam Strength Ratios and Unit-Load Method)

  • 오병관;박효선;최세운
    • 한국전산구조공학회논문집
    • /
    • 제29권6호
    • /
    • pp.563-569
    • /
    • 2016
  • 본 논문에서는 철골모멘트골조의 초기 강성과 연성을 동시에 조절하기 위해 기둥-보 휨강도비를 고려한 재분배 기법이 제시된다. 제시되는 기법은 총 구조물량과 기둥-보 휨강도비에 대한 제약조건을 만족시키면서 구조물의 최상층의 변위를 최소화한다. 고려된 설계변수는 구조부재의 단면적을 사용하며, 정식화된 문제로부터 최적의 결과를 얻기 위해 Sequential Quadratic Programming(SQP) 기법을 사용한다. 최상층의 횡변위에 대한 각 부재의 변위기여도를 단위하중법을 통해 구하고, 이를 최상층의 횡변위가 감소하도록 각 부재의 단면을 재설계한다. 각 부재의 변위기여도를 이용하여 부재의 단면을 재설계하는 과정은 구조물의 초기 강성을 향상시키는 효과를 가진다. 동시에, 제시된 기법은 기둥-보 휨강도비를 제약함으로써 구조물의 연성을 조절하도록 한다. 제시된 최적변위설계기법은 철골골조 예제에 적용하여 적용성을 검증한다. 적용한 결과 제시된 기법을 통해 구조물의 초기강성과 연성능력이 조절되는 것을 확인할 수 있었다.

Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders

  • Prakash, Amar;Anandavalli, N.;Madheswaran, C.K.;Lakshmanan, N.
    • Steel and Composite Structures
    • /
    • 제13권3호
    • /
    • pp.239-258
    • /
    • 2012
  • In this paper, experimental investigations on high strength steel (HSS) stud connected steel-concrete composite (SCC) girders to understand the effect of shear connector density on their flexural behaviour is presented. SCC girder specimens were designed for three different shear capacities (100%, 85%, and 70%), by varying the number of stud connectors in the shear span. Three SCC girder specimens were tested under monotonic/quasi-static loading, while three similar girder specimens were subjected to non-reversal cyclic loading under simply supported end conditions. Details of casting the specimens, experimental set-up, and method of testing, instrumentation for the measurement of deflection, interface-slip and strain are discussed. It is found that SCC girder specimen designed for full shear capacity exhibits interface slip for loads beyond 25% of the ultimate load capacity. Specimens with lesser degree of shear connection show lower values of load at initiation of slip. Very good ductility is exhibited by all the HSS stud connected SCC girder specimens. It is observed that the ultimate moment of resistance as well as ductility gets reduced for HSS stud connected SCC girder with reduction in stud shear connector density. Efficiency factor indicating the effectiveness of high strength stud connectors in resisting interface forces is estimated to be 0.8 from the analysis. Failure mode is primarily flexure with fracturing of stud connectors and characterised by flexural cracking and crushing of concrete at top in the pure bending region. Local buckling in the top flange of steel beam was also observed at the loads near to failure, which is influenced by spacing of studs and top flange thickness of rolled steel section. One of the recommendations is that the ultimate load capacity can be limited to 1.5 times the plastic moment capacity of the section such that the post peak load reduction is kept within limits. Load-deflection behaviour for monotonic tests compared well with the envelope of load-deflection curves for cyclic tests. It is concluded from the experimental investigations that use of HSS studs will reduce their numbers for given loading, which is advantageous in case of long spans. Buckling of top flange of rolled section is observed at failure stage. Provision of lips in the top flange is suggested to avoid this buckling. This is possible in case of longer spans, where normally built-up sections are used.

원형 철근콘크리트 교각의 내진성능 I. 심부구속철근비 영향 변수 평가 (A Seismatic Performance Analysis of Circular RC Bridge Piers I. Evaluation of Influence Parameters of Confinement Steel Ratio)

  • 이대형;박창규;김현준;정영수
    • 콘크리트학회논문집
    • /
    • 제17권4호
    • /
    • pp.603-611
    • /
    • 2005
  • 본 연구에서는 합리적인 내진설계기준의 정립을 위하여 철근콘크리트 교각의 내진성능에 영향을 미치는 주요 인자에 대하여 분석하였다. 주요 각국의 내진규정에서 내진성능을 발휘하기 위한 심부구속철근량을 규정함에 있어 다양한 요소들을 고려하고 있다. 하지만, 이러한 요소들이 합리적으로 고려되었는가에 대해서는 의문이 남는다. 따라서 본 연구에서 국내의 도로교설계기준, Eurocode 8 part2, NZS 3101, ATC-32 등의 설계기준을 비교분석하고, 기존 실험 연구 결과와 비교 분석하여 합리적인 영향인자들을 제안하고자 하였다. 연구결과에 따르면 원형 철근콘크리트 교각의 내진성능에 가장 지배적인 영향인자는 축하중비인 것으로 조사되었다. 따라서 심부구속철근비 산정식에 축하중비의 영향을 전혀 고려하고 있지 않는 현행 도로교설계기준에 축하중비를 도입해야 한다.

축방향철근 연결상세에 따른 철근콘크리트 원형교각의 내진성능 (Seismic Performance of Circular RC Bridge Columns with Longitudinal Steel Connection Details)

  • 이재훈;손혁수;고성현
    • 콘크리트학회논문집
    • /
    • 제16권2호
    • /
    • pp.249-260
    • /
    • 2004
  • 철근콘크리트 교각의 소성힌지 구간에서의 축방향철근의 겹침이음은 내진성능면에서 바람직하지 않으나, 축방향철근의 겹침이음을 피하는 철근상세가 현실적으로 어려운 실정이며 현행 도로교설계기준에는 축방향철근 겹침이음 금지에 관한 특별한 설계기준이 없는 상태이다. 본 연구는 반복하중을 받는 철근콘크리트 원형교각의 축방향철근 연결상세에 따른 내진성능을 평가하기 위해 축방향철근 연결상세에 따른 7개 그룹 총 21개의 원형나선철근 기둥 시험체에 대한 준정적실험을 수행하였다. 실험결과 축방향철근이 겹침이음 되어있는 시험체의 경우, 단일 축방향철근으로 구성된 시험체보다 낮은 내진성능을 나타내었으며 특히, 모든 축방향철근이 겹침이음 되어있는 경우 내진성능이 상당히 저하되었다. 그러나, 축방향철근을 기계적 연결장치로 연결한 시험체의 경우 단일축방향철근 상세를 가지는 시험체와 유사한 내진성능을 나타내었다. 본 연구의 최종목적은 철근콘크리트 교각의 시공성 향상을 위한 축방향철근 연결상세의 제시 및 한정연성 내진설계를 위한 실험적 기초자료의 제공과 함께 성능단계별 축방향철근 연결상세에 따른 성능 및 손상평가를 위한 정량적 수치와 경향을 제공하기 위한 것이며, 극한변위, 극한드리프트비율, 변위연성도, 응답수정계수, 등가점성감쇠비, 잔류변형지수, 유효강성 등의 주요 내진성능평가 변수들에 대한 분석결과를 나타내었다.

Response modification factors of concrete bridges with different bearing conditions

  • Zahrai, Seyed Mehdi;Khorraminejad, Amir;Sedaghati, Parshan
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.185-196
    • /
    • 2019
  • One of the shortcomings of seismic bridge design codes is the lack of clarity in defining the role of different seismic isolation systems with linear or nonlinear behavior in terms of R-factor. For example, based on AASHTO guide specifications for seismic isolation design, R-factor for all substructure elements of isolated bridges should be half of those expressed in the AASHTO standard specifications for highway bridges (i.e., R=3 for single columns and R=5 for multiple column bent) but not less than 1.50. However, no distinction is made between two commonly used types of seismic isolation devices, i.e., elastomeric rubber bearing (ERB) with linear behavior, and lead rubber bearing (LRB) with nonlinear behavior. In this paper, five existing bridges located in Iran with two types of deck-pier connection including ERB and LRB isolators, and two bridge models with monolithic deck-pier connection are developed and their R-factor values are assessed based on the Uang's method. The average R-factors for the bridges with ERB isolators are calculated as 3.89 and 4.91 in the longitudinal and transverse directions, respectively, which are not in consonance with the AASHTO guide specifications for seismic isolation design (i.e., R=3/2=1.5 for the longitudinal direction and R=5/2=2.5 for the transverse direction). This is a clear indicator that the code-prescribed R-factors are conservative for typical bridges with ERB isolators. Also for the bridges with LRB isolators, the average computed R-factors equal 1.652 and 2.232 in the longitudinal and transverse directions, respectively, which are in a good agreement with the code-specified R-factor values. Moreover, in the bridges with monolithic deck-pier connection, the average R-factor in the longitudinal direction is obtained as 2.92 which is close to the specified R-factor in the bridge design codes (i.e., 3), and in the transverse direction is obtained as 2.41 which is about half of the corresponding R-factor value in the specifications (i.e., 5).

Seismic behavior investigation of the steel multi-story moment frames with steel plate shear walls

  • Mansouri, Iman;Arabzadeh, Ali;Farzampour, Alireza;Hu, Jong Wan
    • Steel and Composite Structures
    • /
    • 제37권1호
    • /
    • pp.91-98
    • /
    • 2020
  • Steel plate shear walls are recently used as efficient seismic lateral resisting systems. These lateral resistant structures are implemented to provide more strength, stiffness and ductility in limited space areas. In this study, the seismic behavior of the multi-story steel frames with steel plate shear walls are investigated for buildings with 4, 8, 12 and 16 stories using verified computational modeling platforms. Different number of steel moment bays with distinctive lengths are investigated to effectively determine the deflection amplification factor for low-rise and high-rise structures. Results showed that the dissipated energy in moment frames with steel plates are significantly related to the inside panel. It is shown that more than 50% of the dissipated energy under various ground motions is dissipated by the panel itself, and increasing the steel plate length leads to higher energy dissipation capability. The deflection amplification factor is studied in details for various verified parametric cases, and it is concluded that for a typical multi-story moment frame with steel plate shear walls, the amplification factor is 4.93 which is less than the recommended conservative values in the design codes. It is shown that the deflection amplification factor decreases if the height of the building increases, for which the frames with more than six stories would have less recommended deflection amplification factor. In addition, increasing the number of bays or decreasing the steel plate shear wall length leads to a reduction of the deflection amplification factor.

Force-based seismic design of steel haunch retrofit for RC frames

  • Ahmad, Naveed
    • Earthquakes and Structures
    • /
    • 제20권2호
    • /
    • pp.133-148
    • /
    • 2021
  • The paper presents a simplified force-based seismic design procedure for the preliminary design of steel haunch retrofitting for the seismic upgrade of deficient RC frames. The procedure involved constructing a site-specific seismic design spectrum for the site, which is transformed into seismic base shear coefficient demand, using an applicable response modification factor, that defines base shear force for seismic analysis of the structure. Recent experimental campaign; involving shake table testing of ten (10), and quasi-static cyclic testing of two (02), 1:3 reduced scale RC frame models, carried out for the seismic performance assessment of both deficient and retrofitted structures has provided the basis to calculate retrofit-specific response modification factor Rretrofitted. The haunch retrofitting technique enhanced the structural stiffness, strength, and ductility, hence, increased the structural response modification factor, which is mainly dependent on the applied retrofit scheme. An additional retrofit effectiveness factor (ΩR) is proposed for the deficient structure's response modification factor Rdeficient, representing the retrofit effectiveness (ΩR=Rretrofitted /Rdeficient), to calculate components' moment and shear demands for the retrofitted structure. The experimental campaign revealed that regardless of the deficient structures' characteristics, the ΩR factor remains fairly the unchanged, which is encouraging to generalize the design procedure. Haunch configuration is finalized that avoid brittle hinging of beam-column joints and ensure ductile beam yielding. Example case study for the seismic retrofit designs of RC frames are presented, which were validated through equivalent lateral load analysis using elastic model and response history analysis of finite-element based inelastic model, showing reasonable performance of the proposed design procedure. The proposed design has the advantage to provide a seismic zone-specific design solution, and also, to suggest if any additional measure is required to enhance the strength/deformability of beams and columns.

유효횡구속압력 감소계수를 사용한 RC 기둥의 횡보강근량 평가 (The Volumetric Ratio of Transverse Reinforcement of R/C Columns Considering Effective Lateral Confining Reduction Factor)

  • 김종근;안종문;신성우
    • 콘크리트학회논문집
    • /
    • 제21권3호
    • /
    • pp.311-318
    • /
    • 2009
  • 본 연구는 고축력과 반복횡력을 받는 초고강도 RC 띠철근 기둥의 실험적 연구를 수행하였다. 콘크리트 압축강도 100 MPa 초고강도 RC 띠철근 기둥의 횡보강근의 양을 제안하는 것이다. 철근콘크리트 구조물의 실제 보를 스터브로 이상화한 1/2개 층의 기둥 실험체를 계획하여 1/3 크기의 19개 실험체를 제작하였다. 주요 변수는 축력비, 횡보강근의 형상 및 체적비로 하였다. 실험 결과, 띠철근 기둥의 강도와 연성은 횡보강근의 형상과 체적비의 영향을 받는 것으로 나타났으나, 무엇보다 축력비에 가장 큰 영향을 받는 것으로 나타나 초고강도 콘크리트 기둥의 횡보강근량 설계를 위해서는 축력비에 따른 적절한 횡보강근의 형상으로 보다 합리적인 설계가 이루어져야 할 것으로 판단된다. 또한, 초고강도 철근콘크리트 기둥의 충분한 연성확보를 위하여 최소한의 변위연성능력 4이상을 확보할 수 있도록 설계식을 제안하였다. 따라서 이는 축력비와 함께 횡보강근의 형상, 간격 및 주근의 개수 등을 고려한 유효횡구속감소계수 (${\lambda}^c$)를 적용한 것이므로 횡보강근량 산정시 보다 합리적일 것으로 판단된다.

An extension of an improved forced based design procedure for 3D steel structures

  • Peres, R.;Castro, J.M.;Bento, R.
    • Steel and Composite Structures
    • /
    • 제22권5호
    • /
    • pp.1115-1140
    • /
    • 2016
  • This paper proposes an extension of the Improved Forced Based Design procedure to 3D steel structures. The Improved Forced Based Design (IFBD) procedure consists of a more rational sequence of the design checks proposed in Eurocode 8 and involves a more realistic selection of the behaviour factor instead of selecting an empirical value based on the ductility class and lateral resisting system adopted. The design procedure was tested on a group of four 3D steel structures, composed by moment-resisting frames with three storeys height and the same plan configuration in all storeys. The plan configuration was defined in order to target lateral restrained or unrestrained systems as well as plan regular or irregular structures. The same group of structures was also designed according to the force-based process prescribed in Eurocode 8. The member sizes obtained through the two approaches were compared and the seismic performance was assessed through nonlinear static and time-history analyses. The limit states referred to structural and non-structural damage, considering the two levels design approach, which are the serviceability and the ultimate limit states, were examined. The results obtained reveal that the IFBD leads to more economical structures that still comply with the performance requirements prescribed in Eurocode 8.