• Title/Summary/Keyword: Ductile cast iron

Search Result 166, Processing Time 0.029 seconds

A Study on the Dry Wear Characteristics of Austempered Ductile Cast Iron (오스템퍼링 處理된 球狀黑鉛鑄鐵의 乾燥磨滅 特性에 관한 硏究)

  • 강명순;전태옥;김형자;박흥식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.489-496
    • /
    • 1988
  • This paper is studied to know wear mechanism in variation of austempering temperature and holding time of austempered ductile cast iron against mating material SM45C hardened by heat treatment. The wear tests were carried out by rubbing the annular surface of two test pieces in dry sliding friction. The wear mechanism was investigated by scanning electron microscopy and the retained austenite volume fraction was investigated by X-ray diffractometer. The experimental results show that the wear characteristics depend largely on the oxidation of the testing materials which is influenced by the sliding velocity and distance. The retained austenite has a negative effect during frictional contact because it has increased severe wear by softened surface layer. It is shown experimentally that hard metals have lower frictional resistance and hence the resistance to adhesion is increased due to stronger interatomic linking bonds and increase in the surface energy.

Effect of Two Step Austenitizing Treatment Conditions on the Microstructural Characteristics of ADI (ADI의 조직특성에 미치는 2단 오스테나이트화 처리조건의 영향)

  • Choi, S.L.;Yun, K.H.;Moon, W.J.;Kang, C.Y.;Kim, H.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.11 no.1
    • /
    • pp.46-53
    • /
    • 1998
  • The variation of the mechanical properties, microstructures and the formation of retained austenite with heat treatment conditions in austempered ductile cast iron has been investigated. In the case of austempered ductile cast iron below 25mm diameter, it has been found that a pearlite structure are not obtained under a super cooled condition at range of $0.05^{\circ}C/sec{\sim}10^{\circ}C/sec$, and the matrix is precipitated in graphite, bainite and retained austenite. After austempering treatment the retained austenite is increased with decreasing cooling rate. The elongation increases with decreasing super cooling rate, and the optimum result has been shown to be the elongation of 15.6% at super cooling rate of $0.05^{\circ}C/sec$. The optimum result has been shown to be the tensile strength-elongation balance of $1656kgf/mm^2.%$ and it is more than doubled to as the casting state and continuous cooling condition.

  • PDF

Effects of Risering Design and Alloying Element on Formation of Shrinkage Cavity in Ductile Cast Iron (구상흑연주철의 수축결함생성에 미치는 주조방안 및 합금원소의 영향)

  • Yu, Sung-Kon
    • Korean Journal of Materials Research
    • /
    • v.13 no.2
    • /
    • pp.74-80
    • /
    • 2003
  • The effects of risering design and alloying element on the formation of defects such as external depression, primary and secondary shrinkage cavities in ductile cast iron were investigated. Two types of risering design for the cylindrically step-wise specimen, No. 1(progressive solidification) and No. 2(directional solidification) risering designs, were prepared and six different alloy compositions were casted. In the No. 1 risering design, external depression or primary shrinkage cavities due to liquid contraction were observed in all the specimens from SG 10 to SG 60. The defects caused by liquid contraction seemed to be more affected by risering design than alloying elements. The secondary shrinkage cavities were also observed in all the specimens but a swollen surface was not observed in all the castings. The primary shrinkage cavities were located right under the top surface or connected to the top surface, and were characterized by smooth surfaces. On the other hand, the secondary shrinkage cavities were positioned in the thermal center of the specimen steps 3 and 4, and characterized by rough surfaces. In the No. 2 risering design, no external depression or primary shrinkage cavities due to liquid contraction were observed in all the specimens from SG 10 to SG 60. However, the secondary shrinkage cavities were formed in the thermal center of specimens SG 40, 50 and 60. Like the No. 1 risering design, a swollen surface was not observed in all the castings.

A Study on the Mechanical Properties and Corrosion Resistance of GCD40 by Plasma Nitriding (플라즈마 질화처리한 GCD40의 기계적성질 및 내식성에 관한 연구)

  • Kim, M.K.;Jung, B.H.;Kim, S.S.
    • Journal of Power System Engineering
    • /
    • v.6 no.1
    • /
    • pp.74-81
    • /
    • 2002
  • The characteristics of corrosion resistance for the surface of ductile cast iron(GCD40) by plasma nitriding process have been studied in terms of electrochemical polarization behaviors including corrosion potential($E_{corr}$), anodic polarization trends, polarization resistance($R_p$), and also have been studied microstructures, hardness and specific wear of nitrided layer Nitrided layer showed an enhanced hardness values in all the plasma nitriding condition investigated. In the result of wear test, specific wear of nitrided specimens were much decreased than that of non-treated specimens. In the results of XRD, ${\gamma}'phase\;and\;{\varepsilon}$ phase were detected in nitrided surface. And it was found that ${\varepsilon}$ phase was decreased and ${\gamma}'phase$ was increased respectively, as the nitriding time became longer. In the test of corrosion resistance, natural potentials in all the nitrided specimens were towards noble directions than in the case of non-treated specimens. The measurement of electrode potentials revealed that corrosion resistivity of plasma nitrided specimens were higher than in the case of the non-treated specimens.

  • PDF

Effects of Alloying Elements on the Mechanical Properties of Normalized and Quenched 3.60wt%C-2.60wt%Si Ductile Cast Irons Poured into Shell Stack Mold (쉘 스택 주조 3.60wt%C-2.60wt%Si 조성 구상흑연주철의 Normalizing 및 Quenching 처리 시 기계적 성질에 미치는 합금 원소의 영향)

  • Kim, Hyo-Min;Kwon, Hae-Wook;Yeo, In-Dong;Nam, Won-Sick
    • Journal of Korea Foundry Society
    • /
    • v.30 no.2
    • /
    • pp.66-75
    • /
    • 2010
  • The effects of alloying elements on the mechanical properties of normalized and quenched 3.60wt%C-2.60wt%C ductile cast iron poured into shell stack mold were investigated. The strength and hardness of as-cast specimen were increased and the elongation of it was decreased with the additions of Mn, Cu and Sn. The strength and hardness were increased with the addition of 0.40wt%Mo and then rather decreased with the increased addition of 0.80wt%. The strength and hardness were increased with normalizing treatment and the strengths of normalized specimens were increased slightly with the addition of alloying elements except Mo. Meanwhile the yield strength of the normalized specimen was increased slightly with the addition of Mo, the tensile strength was not changed much. Meanwhile the hardness and strength of the quenched specimen were slightly increased with the addition of Mn, those were almost not changed with the amount added. The tensile strength of the quenched specimen with larger diameter, when the Cu had been added, and the tensile and yield strengths of them, when Mo had been added, were increased with the addition of alloying element. On the other hand, those were not changed with the amount added. For the case of specimen with smaller diameter, there were no effects of these two elements. When Sn had been added, the strength of hardened specimen with larger diameter was slightly increased with the amount added. However, that with smaller diameter was rather decreased with it. The effect of specimen diameter on the strength of quenched specimen with the addition of Cu, Mo and Sn was reduced.

Residual Life Assessment on Cast Iron Pipes of Water Distribution System (상수도관로중 주철관종의 잔존수명 평가에 관한 연구)

  • Lee, Hyun-Dong;Bae, Chul-Ho;Hong, Seong-Ho;Hwang, Jae-Woon;Kwak, Phill-Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.206-214
    • /
    • 2004
  • Residual wall thicknesses, corrosion rates, and residual life of thirty four samples of cast iron pipes(CIPs) and ductile cast iron pipes(DCIPs) collected from water mains of B city were studied to estimate their remaining service life or optimum time of rehabilitation. The internal maximum corrosion depths of samples measured using a dial gauge after shot blasting were twice higher than the external in most cases. Therefore corrosion of water pipes was much more affected by internal water quality than soil. Residual wall thicknesses of DCIPs were higher than those of CIPs. That reason was thought to be that DCIPs have been protected from internal corrosion by lining cement mortar. Residual life calculated by maximum corrosion rate was ranged up to 44 years with 12.40 years average. Since most CIPs were much deteriorated, rehabilitation plan should be established soon in B city. Residual life of DCIP was 33.52 years average. When cement mortar lining is used up by neutralization of DCIPs. DCIP also should be rehabilitated.

Effects of Riser Design and Chemical Composition on the Formation of Shrinkage Cavity in Gray and Ductile Iron Castings

  • Yu, Sung-Kon
    • Journal of Korea Foundry Society
    • /
    • v.24 no.2
    • /
    • pp.101-107
    • /
    • 2004
  • 회주철 및 구상흑연주철에 있어서 압탕방안 및 합금원소가 수축결함의 생성에 미치는 영향을 연구하였다. 두 종류의 압탕방안으로 실린더형상의 계단상시편을 제조하였으며 회주철의 경우 5조성(ISO 150, 200, 250, 300, 350), 구상흑연주철의 경우 6조성(SG 10, 20, 30, 40, 50, 60)을 사용하였다. 회주철 및 구상흑연주칠 공히, 1차 압탕방안의 경우 액상수축에 의한 1차수축결함이 후육부의 표면에 발생하였으며 수축결함의 내면은 매끄러웠다. 회주철의 경우 응고수축에 의한 2차수축결함은 생성되지 않았으나 구상흑연주철의 경우 모든 시편의 내부열점에 2차수축결함이 발생하였고 그 내면은 거칠었다. 2차압탕방안의 경우 회주철의 모든 시편에서는 1차 및 2차수축결함이 발생되지 않았다. 그러나 구상흑연주철의 경우 탄화물 생성원소가 첨가된 SG 40, 50 및 60의 3조성에서 2차수축결함이 열점에 생성되었다. 견고한 ���V주형을 사용하였기 때문에 주형벽이동으로 인한 표면팽창은 어느 경우에도 관찰되지 않았다.

Phase Field Modeling of Graphitization in Ductile Cast Iron by Strip Casting(I);Modeling of Phases with Negligible Solubility (스트립캐스팅한 구상흑연주철 박판의 흑연화 과정에 대한 phase-field 모델링 (I);고용도가 없는 상의 모델링)

  • Kim, Sung-Gyun;Ra, Hyung-Yong
    • Journal of Korea Foundry Society
    • /
    • v.20 no.2
    • /
    • pp.129-140
    • /
    • 2000
  • This study aims at the phase-field modeling of the phase transformation in graphitization of the cast iron. As the first step, we constructed a phase-field model including the phases with negligible solubility. Under the dilute regular solution approximation, a simplified version of the phase-field model was obtained, which can be used for the phase transformation related with the stoichiometric phases. The results from the numerical calculation of the phase-field model was in good agreement with the exact analytic solution. The compositional shift due to Gibbs-Thomson effect can be reproduced within 0.5% error in the numerical calculation. The interface velocity, whereas, in numerical calculation of phase-field model appeared to be 15% larger than that from the analytic solution. This error is due to the shift of the interface position in phase-field model from the position with ${\phi}=0.5$.

  • PDF

A Study on the Wear Characteristics of Austempered Ductile Iron (오스템퍼링한 구상흑연주철의 마모특성에 미치는 기지조직의 영향에 관한 연구)

  • Kim, Yun-Bog;Kim, Chang-Gyu;Choi, Chang-Ock
    • Journal of Korea Foundry Society
    • /
    • v.10 no.3
    • /
    • pp.235-246
    • /
    • 1990
  • This study has been carried out to investigate into the rolling wear characteristics of austempered ductile iron under unlubricated dry rolling condition by Amsler type test with 9.09% sliding ratio. Wear amount is increased with increasing of ferrite and retained austenite and it has been found that the amount of rolling wear is decreased when the hardness of matrix are higher. The rolling life up to generation of abnormal condition is conspicusly increased and amount of rolling wear is increased asrolling revolutionis increased and wear of austempered ductile ironunder dry rolling condition. Matrix has been obtained to upper bainite, low bainite at heat treatment, obtained to bull`s eye structure at as cast. It has been found that the amount of rolling wear is decreased when the tensile strength of the casting are increased and then the rolling life up to generation of abnormal wear in conspicuously increased and amount of wear was intend to graphite content.

  • PDF

Effects of 2-Phase Matrix Structure on Fatigue Limit of High Strength Ductile Iron (고강도 구상흑연주철의 피로한도에 미치는 2상 기지조직의 영향)

  • Kim, Jin-Hak;Ji, Jueng-Keun;Kim, Min-Gun
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.75-79
    • /
    • 1999
  • Rotary bending fatigue tests were performed to investigate the effects of 2-phase matrix structure on fatigue limit with prepared specimens in high strength ductile irons. Two types of the specimens with different microstructures have been used. Series A has sorbite and series B has bainite. Fatigue limits of both specimens are improved comparing with as cast specimen. The fatigue limit is higher in series B than in series A. The reason why the fatigue limit of series A shows inferiority to that of series B is due to the transition of micro fatigue cracks to mesocrack occurs very rapidly, so increased stress intensity factor drives the fatigue crack growth. The higher fatigue limit of series B which has bainite is caused by the ${\gamma}$ layer contained in microstructure impede the rapid growth of micro fatigue crack to mesocrack and ${\alpha}$ layer around graphite has the higher capacity for the absorption of plastic deformation energy than sorbite.

  • PDF