• 제목/요약/키워드: Duct area

검색결과 233건 처리시간 0.026초

한국염소에서 실험적 총담관부분 및 완전폐쇄에 따른 임상생화학적 연구 (Clinico-biochemical Study on Experimental Partial and Complete Obstruction of the Common Bile Duct in Korean Goats)

  • 유라경;정종태;남치주
    • 한국임상수의학회지
    • /
    • 제8권1호
    • /
    • pp.71-80
    • /
    • 1991
  • Clinical signs, serum chemical values and histological findings of hepatic tissue after partial and complete obstruction of common bile duct in Korean goats were investigated. Abnormal clinical signs were not observed in partial obstruction of common bile duct, but in complete obstruction clinical signs such as jaundice, urine color change, were observed. Serum total bilirubin, total cholesterol, aspartate aminotransferase, sorbitol dehydrogenase, gamma glutamyltranspeptidase, and total protein values increased on the 1-4th day and then gradually decreased to normal level in partial obstruction. However, they tend to increase persistently by the 24th day in complete obstruction of common bileduct. Histologic features of hepatic tissue in partial obstruction were not changed as compared with normal hepatic tissue. On the other hand, in complete obstruction of common bite duct there were moderate bile duct proliferation in a portal area, rupture of bile canaliculi, phagocytosis of bile pigment by Kupffer cells, periportal fibrosis, intrahepatic bile stasis and hepatic cell necrosis.

  • PDF

주덕트의 단면적 변화가 분지덕트의 유량분배에 미치는 영향 (Effect of a Variation of a Main Duct Area on Flow Distribution of Each Branch)

  • 이재호;김범준;조대진;윤석주
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.386-395
    • /
    • 2005
  • With the development of a living standard, the importance of indoor air conditioning system in all kinds of buildings and vehicles has increased. A lot of researches on energy losses in a duct and various kinds of flow pattern in branches or junctions have been carried out over many years, because the primary object of a duct system used in HVAC is to provide equal flow rate in the interior of each room by minimizing pressure drop. In this study, to get equal flow distribution in each branch, a blockage is applied to the rectangular duct system. The flow analysis for flow distribution of a rectangular duct with two branches was performed by CFD. By using SIMPLE algorithm and finite volume method, flow analysis is performed in the case of 3-D, incompressible, turbulent flow. Also, the standard $k-{\varepsilon}$ model and wall function method were used for analysis of turbulent fluid flow. The distribution diagrams of static pressure, velocity vector, turbulent energy and kinetic energy in accordance with variation of Reynolds number and blockages location in a rectangular duct show that flow distribution at duct outlets is improved by a blockage. In this rectangular duct system, mean velocity and flow rate distribution in two branch outlets are nearly constant regardless of variation of Reynolds number, and a flow pattern of the internal duct has a same tendency as well.

CFD를 이용한 KRISO 추진효율 향상 장치(K-duct) 형상 특성에 관한 연구 (A Study on the Shape of KRISO Propulsion Efficiency Improvement Devices(K-duct) using CFD)

  • 김진욱;서성부
    • 대한조선학회논문집
    • /
    • 제55권6호
    • /
    • pp.474-481
    • /
    • 2018
  • This paper is to compare by numerical analysis the flow characteristics and propulsion performance of stern with the shape change of K-duct, a pre-swirl duct developed by Korea Research Institute of Ships & Ocean Engineering (KRISO). First, the characteristics of the propeller and the resistance and self-propulsion before and after the attachment of the K-duct to the ship were verified and the validity of the calculation method was confirmed by comparing this result with the model test results. After that, resistance and self-propulsion calculations were performed by the same numerical method when the K-duct was changed into five different shapes. The efficiency of the other five cases was compared using the delivery horsepower in the model scale and the flow characteristics of the stern were analyzed as the velocity and pressure distributions in the area between the duct end and the propeller plane. For the computation, STAR-CCM +, a general-purpose flow analysis program, was used and the Reynolds Averaged Navier-Stokes (RANS) equations were applied. Rigid Body Motion (RBM) method was used for the propeller rotating motion and SST $k-{\omega}$ turbulence model was applied for the turbulence model. As a result, the tangential velocity of the propeller inflow changed according to the position angle change of the stator, and the pressure of the propeller hub and the cap changes. This regulated the propeller hub vortex. It was confirmed that the vortex of the portion where the fixed blade and the duct meet was reduced by blunt change.

차압제연설비의 성능과 관련된 시스템 및 환경 변수와의 상관성 분석 (The Analysis of Correlation Major System Factors with the Performance of Smoke Control Systems Using Pressure Differentials)

  • 여용주;김학중;박용환
    • 한국화재소방학회논문지
    • /
    • 제24권2호
    • /
    • pp.97-105
    • /
    • 2010
  • 압력차를 이용한 연기제어기법은 피난계단 또는 대피공간으로 연기의 유입을 방지하기 위한 방법 중 가장 많이 알려져 있다. 그럼에도 불구하고 국내에서는 기술에 대한 이해부족에 기인한 많은 문제점이 발생하고 있다. 그러한 관점에서 차압제연설비의 성능에 영향을 미치는 주요인자인 풍도면적, 급기댐퍼의 개구면적, 부속실 개방에 따른 영향, 연돌효과 그리고 급기주입구의 위치가 시스템의 성능에 어떠한 영향을 미치는지를 분석하였다. 중요한 결론으로는 풍도의 단면적이 작을수록 마찰손실이 증가하여 적절한 차압을 유지할 수 없었으며, 특히 연돌효과는 저층부의 압력차를 작게 만들어 차압제연시스템의 성능을 약화시키는 가장 큰 요인으로 확인되었다.

Analytical Study on Stall Stagnation Boundaries in Axial-Flow Compressor and Duct Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권2호
    • /
    • pp.56-74
    • /
    • 2013
  • Stall stagnations in the system of axial-flow compressors and ducts occur in transition from deep surge conditions to decayed or converged stall conditions. The present study is concerned with the boundaries between the deep surges and the stagnation stalls on the basis of analytical results by a code on surge transients analysis and simulation. The fundamental acoustical-geometrical stagnation boundaries were made clear from examinations of the results on a variety of duct configurations coupled with a nine-stage compressor and a single stage fan. The boundary was found to be formed by three parts, i.e., B- and A-boundaries, and an intermediate zone. The B-boundary occurs for the suction-duct having a length of about a quarter of the wave-length of the first resonance in the case of very short and fat plenum-type delivery duct. On the other hand, the A-boundary occurs for the long and narrow duct-type delivery flow-path having a length about a fifth of the wavelength and relatively small sectional area in the case of short and narrow suction ducts. In addition to this, the reduced surge-cycle frequencies with respect to the duct lengths are observed to have respective limiting values at the stagnation boundaries. The reduced frequency for the B-boundary is related with a limiting value of the Greitzer's B parameter. The tendency and the characteristic features of the related flow behaviors in the neighborhood of the boundaries were also made clearer.

골결손을 동반한 비구개관 낭종의 치험례 (A Clinical Experience of Nasopalatine Duct Cyst with Bony Defect)

  • 김영진;서제원;전영준;김성식
    • Archives of Plastic Surgery
    • /
    • 제32권2호
    • /
    • pp.255-258
    • /
    • 2005
  • The nasopalatine duct cyst, known as the incisive canal cyst, is the most common nonodontogenic cyst in the maxillofacial area. It is believed to arise from epithelial remnants of the embryonic nasopalatine duct. Nasopalatine duct cysts are most often detected in patients between forties and sixties. The trauma, bacterial infection, or mucous retention has been suggested as etiological factors. The cysts often present as asymptomatic swelling of the palate but can present with painful swelling or drainage. Radiologic findings include a well demarcated cystic structure in a round, ovoid or heart shape presenting with a well-defined bone defect in the anterior midline of the palate between and posterior to the central incisors. Most of them are less than 2cm in size. On MRI, the cyst is identified as a high-intensity, well-marginated lesion, which indicates that it contains proteinaceous material. We experienced a case of a 61-year-old female patient who had a $2.3{\times}2.6{\times}1.7cm$ sized nasopalatine duct cyst. The bony defect after a surgical extirpation was restored with hydroxyapatite. So we report a good results with some reviews of the literatures.

Asymptomatic Bile Duct Dilatation in Children: Is It a Disease?

  • Son, Yeo Ju;Lee, Mi Jung;Koh, Hong;Kim, Seung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제18권3호
    • /
    • pp.180-186
    • /
    • 2015
  • Purpose: Bile duct dilatation is a relatively common sonographic finding; nevertheless, its clinical significance in children is controversial because little research has been done in the area. Therefore, we investigated the natural course and clinical significance of biliary duct dilatation in children. Methods: We performed a retrospective study of 181 children (range, 1-day-old to 17-year-old) in whom dilatation of the intrahepatic duct and/or common hepatic duct and/or common bile duct was detected by abdominal ultrasonography at the Severance Children's Hospital between November 2005 and March 2014. We reviewed and analyzed laboratory test results, clinical manifestations, and clinical course in these patients. Results: Pediatric patients (n=181) were enrolled in the study and divided into two groups. The first group included 59 subjects, without definitive cause of bile duct dilatation, who did not require treatment; the second group included 122 subjects, with definitive cause of bile duct dilatation or underlying biliary disease, who did require treatment. In the first group, 24 patients (40.7%) showed spontaneous resolution of bile duct dilatation, 20 patients (33.9%) showed no change, and 15 patients (25.4%) were lost to follow-up. In the second group, 31 patients were diagnosed with choledochal cysts, and 91 patients presented with biliary tract dilatations due to secondary causes, such as gallbladder or liver disease, post-operative complications, or malignancy. Conclusion: Biliary dilatation in pediatric patients without symptoms, and without laboratory and other sonographic abnormalities, showed a benign clinical course. No pathologic conditions were noted on follow-up ultrasonography.

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

닥트에 분사되는 제트플륨의 수치계산 (Simulation of Jet Plume Impinging onto a Duct)

  • 홍승규;이광섭;백동기
    • 한국전산유체공학회지
    • /
    • 제2권2호
    • /
    • pp.44-50
    • /
    • 1997
  • Accurate simulation of jet plume exhausting into the open space as well as onto the opposing wall is of interest both numerically and physically; the latter, from a system designer's point of view. In the current work, Navier-Stokes computation is undertaken to capture the flow pattern of a supersonic jet impinging onto a rectangular duct which deflects the vertical jet horizontally. Of particular interest are the flow structure in the jet exhaust area, pressure pattern and the magnitude of pressure force at the bottom wall. Usefulness of present characteristic boundary condition applied at the exiting plane of the duct is demonstrated by capturing such complex flow structures for different lengths of the deflection duct.

  • PDF

입구덕트 공기유량 및 압력손실 예측방법 (The Prediction of Air Flow and Pressure Loss at Inlet Duct)

  • 이보화;이경재;양수석
    • 한국추진공학회지
    • /
    • 제14권1호
    • /
    • pp.48-55
    • /
    • 2010
  • 본 논문에서는 엔진고공환경 시험설비의 엔진 입구 덕트에서 측정한 전압력과 정압력 및 전온도를 통해 실시간으로 공기유량을 계산하고, 압력프로파일을 이용하여 경계층 레이크를 장착하지 않았을 경우에도 공기유량을 예측할 수 있는 방법을 기술하였다. 또한, 엔진입구배관에 걸친 덕트 연결부를 통한압력손실을 예측하고, 이를 통해 공기유량을 보정함으로써, 고공환경시험설비에서의 공기유량측정의 신뢰도를 향상시키고 설비유지측면에서의 운용성을 보고자 하였다.