Abstract
The purpose of this paper was to address the methodology of the air flow measurement using duct mach number that was considered area-weighed average obtained by total, static pressure and temperature measured at engine inlet duct. Without installing boundary rake, the prediction of air flow measurement was discussed. Actual air flow measurement and pressure value using pressure loss through inlet seal were described to improve the reliability and operability of altitude engine test facility.
Keywords
Altitude Engine Test Facility; Duct mach number; Airflow; Pressure loss; Rake;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Robert W. Fox, Alan T. McDonald, Pilip J. Pritchard., "Introduction to fluid mechanics", 1934, pp.162
2 AGARD, "Uniform Engine Testing Program Phase I "
3 이진근, 김춘택, 양수석, 이대성 "고공 환경엔진 시험," 한국추진공학회지, 제9권 4호, 2005, pp.104-111   과학기술학회마을
4 Measurement of fluid flow by means of pressure differential devices-Part 1, ISO5167-1, 1991-12-15
5 한국항공우주연구원, "비행체 추진기관 고공성능시험의 신뢰도 향상과 비정상상태 시험 기술에 관한 연구", 2004