• Title/Summary/Keyword: Duck detection

Search Result 188, Processing Time 0.034 seconds

Invasive cervical resorption: treatment challenges

  • Kim, Yookyung;Lee, Chan-Young;Kim, Euiseong;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.228-231
    • /
    • 2012
  • Invasive cervical resorption is a relatively uncommon form of external root resorption. It is characterized by invasion of cervical region of the root by fibrovascular tissue derived from the periodontal ligament. This case presents an invasive cervical resorption occurring in maxillary lateral incisor, following damage in cervical cementum from avulsion and intracoronal bleaching procedure. Flap reflection, debridement and restoration with glass ionomer cement were performed in an attempt to repair the defect. But after 2 mon, more resorption extended apically. Considering root stability and recurrence potential, we decided to extract the tooth. Invasive cervical resorption in advanced stages may present great challenges for clinicians. Therefore, prevention and early detection must be stressed when dealing with patients presenting history of potential predisposing factors.

A Study on the Deteriorated Cause Analysis of Mold Type Potential Transformer (몰드형 계기용 변압기의 소손원인 해석에 관한 연구)

  • Choi, Chung-Seog;Kim, Hyug-Soo;Shong, Kil-Mok;Kim, Hyung-Rae;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1557-1559
    • /
    • 2000
  • In this paper, we intend to establish the judgement of electrical fire through analysis of PT(Potential Transformer) using the power installation. The columnar structure and the void generated by abrupt heat grew at the tenter of boundary-face on the metallurgical microscope analysis. The detection of OK lines was confirmed by EDX(Energy Dispersive X-ray spectroscopy) as melting and recombination due to the layer-short of the wiring. We found that the thermal-weight decrease occurred at 300$^{\circ}C$ in case of being the thermal-deterioration on the base of the result that analyzed the insulated-materials by using TGA, and the thermal reaction limited-value of PT insulator was about 300$^{\circ}C$ on the DSC curve. As this analysis, we confirmed what the layer-short appeared in the wiring of PT.

  • PDF

Statistic Pattern Analysis of HFPD According to Applied Stress (인가 스트레스에 따른 HFPD의 통계적 패턴해석)

  • Kim, Duck-Keun;Lee, Eun-Suk;Jung, Young-Ill;Lim, Jang-Seub;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.18-22
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A Study on the Sensitivities Characteristics in a PD and a HFPD (PD 측정과 HFPD의 감도특성에 관한 연구)

  • Lim, Jang-Seob;Kim, Duck-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.29-32
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires on-line & on-site diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and PD/HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

Sensorless Starting Method and Fuel Pressure Control of BLDC Motor for Fuel Pump of Vehicle (자동차 연료 펌프용 BLDC 모터의 센서리스 기동 및 연료 압력 제어)

  • Chang, Jin-Wook;Yoon, Duck-Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.114-121
    • /
    • 2013
  • High efficiency operation is required for motors of vehicle to increase fuel efficiency due to the regulation of exhaust gas. This paper presents a control method of fuel pressure to increase fuel efficiency and a sensorless control method of BLDC motor to get higher efficiency than conventional brushed DC motor. Initial rotor position of BLDC motor is detected from current value that is occurred by test voltage pulse and rotor is accelerated by defined sequence to enter sensorless operation mode. The algorithm to control flow rate of fuel pump uses PI controller that is control motor speed to maintain the target fuel pressure commanded by ECU.

Human Eye Detection using Skin Color and Moments (피부색과 모멘트를 이용한 눈 영역 검출)

  • Seo, Duck-Won;Yun, Kug-Jin;Kim, Dae-Jung;Kwak, Hoon-Sung
    • Annual Conference of KIPS
    • /
    • 2001.04a
    • /
    • pp.143-146
    • /
    • 2001
  • 본 논문에서는 칼라 영상으로부터 피부색 정보 및 모멘트를 이용하여 눈 영역 및 얼굴 영역을 검출하는 알고리즘을 제안한다. 제안한 알고리즘은 눈 영역을 추출함으로써 보다 정확한 얼굴 영역을 검출할 수 있다. 이를 위해 먼저 입력된 칼라 영상의 피부색 정보를 기반으로 추출한 영역으로부터 레이블 영역의 면적과 크기 정보를 이용해 1차, 2차 얼굴 후보 영역을 선택하고 선택된 얼굴 후보 영역간의 기울기 모멘트를 계산하여 3차 얼굴 후보 영역을 추출한다. 또한 추출한 3차 후보 영역으로부터 레이블 영역의 크기 및 구조적 관계를 고려하여 영역 내에서의 눈의 위치를 검출한다. 따라서 제안한 방법은 눈의 기울기 관계를 이용함으로써 얼굴의 크기와 얼굴이 좌우로 기울어진 영상에 대하여 강인한 얼굴 검출 능력을 보인다.

  • PDF

Development of Waterproof Acoustic Sensor for Shockwave Measurement (탄환 충격파 측정용 방수 음향센서 개발)

  • Hur, Shin;Lee, Duck-Gyu
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.318-322
    • /
    • 2019
  • In shooting training, an impact point identification system that uses the impact wave of the bullet to check the impact point in the target plate has been recently used. Acoustic sensors used in these systems must be able to detect shock waves of high sound pressure levels and be both waterproof and dustproof for rainy weather and dusty environments, respectively. In this study, membranes with excellent waterproof, dustproof, and sound transmitting characteristics were selected through a characteristics test; a protection cap was installed to install the selected materials. After coupling the produced protection cap to the acoustic sensor housing, the sensitivity and phase characteristics of the acoustic sensor were checked. Through the waterproof and dustproof test, the performances of its sensitivity and phase characteristics were confirmed. Finally, the normal shockwave of a 5.56 mm diameter bullet was measured using a shockwave detection signal collecting plate equipped with a prototype of the acoustic sensor at a 100 m firing range.

Analysis of Low Molecular Weight Collagen by Gel Permeation Chromatography

  • Yoo, Hee-Jin;Kim, Duck-Hyun;Park, Su-Jin;Cho, Kun
    • Mass Spectrometry Letters
    • /
    • v.12 no.3
    • /
    • pp.81-84
    • /
    • 2021
  • Collagen, which accounts for one-third of human protein, is reduced due to human aging, and much attention is focused on making collagen into food to prevent such aging. Gel permeation chromatography with Reflective Index (RI) detection (GPC/RI) was chosen as the most suitable instrument to confirm molecular weight distribution, and we explored the use of this technique for analysis of collagen peptide molecular sizes and distributions. Data reliability was verified by matrix-assisted laser desorption/ionization coupled to time-of-flight (MALDI-TOF) mass spectrometric analysis. The data were considered meaningful for comparative analysis of molecular weight distribution patterns.

The Design of Detection System on the Sensor Stream Data for Stable Railway improvement based on Server Environment (철도 안정성 개선을 위한 서버 기반 스트림 데이터 감지 시스템 설계)

  • Lee, Jin-Hyeong;Oh, Ryum-Duck
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.267-270
    • /
    • 2021
  • 본 논문에서는 기차의 운행 중 철도에서의 여러 위험 요소를 관리하기 전, 이를 테스트 하기 위해 기차 모형의 특정 부위나 철도 혹은 주변 요소에 아두이노 센서를 부착하여 감지된 값을 제공하고, 수집한 스트림 데이터를 브라우저 화면에 실시간으로 출력하여 모니터링하는 웹 애플리케이션을 설계하고 구현한다. 이를 통해 사용자는 웹을 이용하여 손쉽고 간편하게 철도에서의 상황 정보가 변화하는 것을 파악할 수 있고, 문제 발생 시 데이터를 분석하여 어떤 문제가 있는지 알 수 있다. 이를 이용하여 여러 애플리케이션과 연동해서 사용자에게 편의성과 편리성을 제공한다.

  • PDF

The Detection and Analysis System for Indoor Fine Dust/Gas on the Smart Multi-Sensor (스마트 다중 센서기반 실내 미세먼지/가스 탐지 및 분석 시스템)

  • Kim, Si-Won;Kim, Seong-Su;Jung, Ju-Ho;Oh, Ryum-Duck;Ahn, Jun-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.01a
    • /
    • pp.67-68
    • /
    • 2020
  • 본 논문에서는 미세먼지 센서와 가스 센서를 이용한 효율적인 스마트 홈 기반 다중 센서 알림 시스템을 제안한다. 시스템은 여러 유형의 홈 센서를 이용하여 효율적으로 미세먼지와 실내의 가스를 탐지 후 실시간으로 애플리케이션을 통해서 사용자에게 탐지 결과를 알려주는 시스템이다. 본 시스템의 경우 기존에 존재하는 미세먼지 센서와 가스 센서를 적용한 측정 시스템에 비해 소액으로 최적의 시스템을 구축할 수 있다. 시스템은 기존의 가스 센서와 다르게 한 번에 다양한 종류의 가스를 탐지해 사용자에게 여러 정보를 제공할 수 있도록 개발하였다.

  • PDF