• Title/Summary/Keyword: Dual-source CT

Search Result 30, Processing Time 0.023 seconds

Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD (뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가)

  • Byeong-Geun Shin;Seong-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.809-817
    • /
    • 2023
  • Single source and dual source measurements using anthropomorphic phantoms in which the phantoms are lined up in human body equivalents use OSLD (Optically Stimulated Luminescence Dosimeter), so the effective dose is calculated using OSLD. For hospital images, SNR (Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were measured in MCA (Middle Cerebral Artery) for single source and dual source, and for phantom images, SNR and CNR were measured for brain parenchyma of single source and dual source. For hospital imaging, SNR and CNR were measured in MCA for both single-source and dual-source, and for phantom images, SNR and CNR were measured for brain parenchyma from single-source and dual-source. As a result of comparing the SNR and CNR of the hospital image and the phantom image, there was no statistical difference. Comparing patient doses in hospital images, the effective dose of the dual source was 53.53% less and the effective dose of the dual energy phantom was 57.94% less. The dose can be increased in other areas, but the cerebrovascular area is useful because the dose is small.

Evaluate the diagnostic accuracy in the assessment of coronary artery stenoses using MDCT (MDCT를 이용한 관상동맥협착 진단의 정확성 평가)

  • Yang, Won-Seok;Sin, Sung-Gyu;Park, Jae-Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.275-279
    • /
    • 2012
  • Methods and results : The suspected patient who have results of CTA and CAG examinations to evaluate coronary stenose to undergo each 16MD CT(n=93) and dual source CT(n=100). As a results of statistic, the highest rank of sensitivity, specificity, PPV, NPV and accuracy in coronary artery with using 16MDCT was displayed in LAD(73.5%), RCA(74.5%), LAD(66.7%), LCX(75%), LCX(67.7%). The mean diagnostic accuracy of dual source CT was more 17% than 16MDCT. Dual source CT was recorded 84% mean of accuracy. In addition to, segments of coronary artery did not show significant differences in all of them. However, distal segment become more and more accurate than proximal site.

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering

  • Goo, Hyun Woo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1031-1041
    • /
    • 2018
  • Objective: To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. Materials and Methods: Eighty-six children (${\leq}3$ years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. Results: There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 ($1.13{\pm}0.09mGy$) and group 2 ($1.07{\pm}0.12mGy$, p < 0.02). Among image quality parameters, significantly higher image noise ($3.8{\pm}0.7$ Hounsfield units [HU] vs. $3.3{\pm}0.6HU$, p < 0.001), significantly lower signal-to-noise ratio ($105.0{\pm}28.9$ vs. $134.1{\pm}44.4$, p = 0.001) and contrast-to-noise ratio ($84.5{\pm}27.2$ vs. $110.1{\pm}43.2$, p = 0.002), and significantly less diaphragm motion artifacts ($3.8{\pm}0.5$ vs. $3.7{\pm}0.4$, p < 0.04) were found in group 1 compared with group 2. Image quality grades of cardiac structures, coronary arteries, ascending aorta, pulmonary trunk, lung markings, and chest wall showed no significant difference between groups (p > 0.05). Conclusion: In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.

Comparison of Radiation Doses between 64-slice Single Source and 128-slice Dual Source CT Coronary Angiography in patient (64-slice single source CT와 128-slice dual source CT를 이용한 관상동맥 조영 검사 시 환자선량 비교)

  • Kang, Yeong-Han
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2012
  • The purpose of this study was to estimate radiation doses from 64-slice single source Computed Tomography(SSCT) coronary angiography(CA) and 128-slice dual source Computed Tomography(DSCT). With SSCT CA, the effective dose averaged approximately 13.86 mSv when two dose modulation was not. The mean effective dose for DSCT CA with retrospectively gated helical(RGH) technique was 11.87 mSv, when prospective ECG gating transverse(PGT) without dose modulation technique was 5.61 mSv. The one with dose modulation in PGT technique and flash mode were 3.04 mSv and flash mode was 0.98 mSv respectively. The lifetime attributable risk(LAR) of cancer incidence from SSCT RGH mode averaged approximately 1 for 1,176, and DSCT averaged 1 for 1,960(RGH mode), 1 for 3,030(PGT without modulation), 1 for 5,882(PGT with modulation). Because of CTCA is associated with non-negligible risk of cancer. Doses can be reduced by application PGT, FLASH than RGH using DSCT.

A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm (Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용)

  • Park, Ki Seok;Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2021
  • Metal material inserted into the body have a large difference in density from human tissues or bones around the Metal during CT scans.. Therefore, the Metal material inserted into the body produces Artifact. Metal Artifact, which occurs around Metals, can degrade the quality of CT images, causing confusion when medical team diagnose lesions. Through this experiment, we confirm that the occurrence of Artifacts decrease by using Dual energy CT and MAR algorithm in Single source Dual energy CT. We also want to present basic data on clinical application methods by comparing and analyzing the characteristics of images obtained by each method. Using GE 750HD CT, artificial implants were scanned using general method and Dual energy. Then we apply the MAR algorithm to each image obtained. And all previously acquired images were compared and analyzed the characteristics of the examination, such as image quality evaluation and dose evaluation. Images with MAR algorithm and Dual Energy confirmed a decrease in Metal Artifact. Images with MAR algorithm have reduced Metal Artifact, but have the disadvantage of distorting the details of artificial joint implants. On the other hand images teseted with Dual Energy have the advantage of being able to implement details than those applied with MAR algorithms, it takes longer to reconstruct the image and the exposure dose was about four times higher than those applied with MAR algorithm. In order to locate Metals, such as the post-operative follow-up period, it is useful to apply MAR algorithm to obtain images. And it is more useful to examine with Dual Energy when micro lesion identification, such as cardiac examination, and surgical planning or when tests are performed in diagnostic way.

Comparison of Radiation Dose and Image Quality between the 2nd Generation and 3rd Generation DualSource Single-Energy and Dual-Source Dual-Energy CT of the Abdomen (2세대와 3세대 이중 소스 단일 에너지와 이중 소스 이중 에너지를 이용한 복부 컴퓨터단층촬영의 방사선량 및 영상 품질 비교)

  • Chang Gun Kim;See Hyung Kim;Seung Hyun Cho;Hun kyu Ryeom;Won Hwa Kim;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1342-1353
    • /
    • 2022
  • Purpose We compared the radiation dose and image quality between the 2nd generation and the 3rd generation dual-source single-energy (DSSE) and dual-source dual-energy (DSDE) CT of the abdomen. Materials and Methods We included patients undergoing follow-up abdominal CT after partial or radical nephrectomy in the first 10 months of 2019 (2nd generation DS CT) and the first 10 months of 2020 (3rd generation DS CT). We divided the 320 patients into 4 groups (A, 2nd generation DSSE CT; B, 2nd generation DSDE CT; C, 3rd generation DSSE CT; and D, 3rd generation DSDE CT) (n = 80 each) matched by sex and body mass index. Radiation dose and image quality (objective and subjective qualities) were compared between the groups. Results The mean size-specific dose estimation of 3rd generation DSDE CT group was significantly lower than that of the 2nd generation DSSE CT (42.5%, p = 0.013) and 2nd generation DSDE CT (46.9%, p = 0.015) groups. Interobserver agreement was excellent for the overall image quality (intraclass correlation coefficient [ICC]: 0.8867) and image artifacts (ICC: 0.9423). Conclusion Our results showed a considerable reduction in the radiation dose while maintaining high image quality with 3rd generation DSDE CT as compared to the 2nd generation DSDE CT and 2nd generation DSSE CT.

Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries (외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사)

  • Jahng, Geon-Ho;Yang, Dal-Mo;Sung, Dong-Wook;Lee, Kwang-Yong;Kim, Hyeog-Ju
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.276-284
    • /
    • 2008
  • A computed tomography (CT) is a powerful system for the effectively fast and accurate diagnosis. The CT system, therefore, has used substantially and developed for improving the performance over the past decade, resulting in growing concerns over the radiation dose from the CT. Advanced CT techniques, such as a multidetector row CT scanner and dual energy or dual source CT, have led to new clinical applications that could result in further increases of radiation does for both patients and workers. The objective of this study was to review the international guidelines of the shielding requirements for a CT facility required for a new installation or when modifying an existing one. We used Google Search Engine to search the following keywords: computed tomography, CT regulation or shield or protection, dual energy or dual source CT, multidetector CT, CT radiation protection, and regulatory or legislation or regulation CT. In addition, we searched some special websites, that were provided for sources of radiation protection, shielding, and regulation, RSNA, AAPM, FDA, NIH, RCR, ICRP, IRPA, ICRP, IAEA, WHO (See in Table 1 for full explanations of the abbreviations). We finally summarized results of the investigated materials for each country. The shielding requirement of the CT room design was very well documented in the countries of Canada, United States of America, and United Kingdom. The wall thickness of the CT room could be obtained by the iso-exposure contour or the point source method. Most of documents provided by international organizations were explained in importance of radiation reduction in patients and workers. However, there were no directly-related documents of shielding and patient exposure dose for the dual energy CT system. Based international guidelines, the guideline of the CT room shielding and radiation reduction in patients and workers should be specified for all kinds of CT systems, included in the dual energy CT. We proposed some possible strategies in this paper.

  • PDF

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.