• Title/Summary/Keyword: Dual system

Search Result 2,722, Processing Time 0.027 seconds

A Study on the Characteristics Analysis of Cutting Fluid Aerosol Using Dual-PDA System - for Turning Process (Dual-PDA를 이용한 절삭유 에어로졸 특성분석에 관한 연구(I) -선삭공정을 중심으로)

  • Jeong, J.Y.;Hwang, D.C.;Hong, G.B.;Woo, C.K.;Hwang, J.
    • Journal of ILASS-Korea
    • /
    • v.10 no.2
    • /
    • pp.10-17
    • /
    • 2005
  • The proposed research has been performed to know the characteristics of cutting fluid aerosol formation using Dual-PDA system in machining process. The cutting fluid aerosol size and concentration is common attributes that quantify the environmental intrusiveness or air quality contamination. The atomized cutting fluid aerosols can be affected to human health risk such as lung cancer and skin irritations. Even though cutting fluid can be improved the machining quality and productivity in a carefully. its use must be controlled and optimized carefully. This experimental works using Dual-PDA were performed to analyze the cutting fluid aerosol behaviors and characteristics in turning process using precise aerosol particle measuring system. The obtained experimental results profovide basic knowledge to develop the environmentally conscious machining process. This results cail be provided as a basis to estimate and control the hazardous cutting fluid aerosol in machining process.

  • PDF

Improvement of Rapid Sand Filtration to Two Stage Dual Media Filtration System in Water Treatment Plant (정수처리장내 급속모래 여과지의 이단복합여과시스템으로의 개량)

  • Woo, Dal-Sik;Hwang, Kyu-Won;Kim, Joon-Eon;Hwang, Byung-Gi;Jo, Kwan-Hyung
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.141-149
    • /
    • 2011
  • This study aimed for developing a two stage dual media filtration system. It has a sand and activated carbon layer above the under-drain system, and a sand layer above the middle-drain system for pretreatment. When retrofitting an old sand filter bed or designing a new one, this technology can substitute the existing sand filter bed without requiring a new plant site. The removal rate of total particle is 93, and 3~7 ${\mu}m$ and 5~15 ${\mu}m$ particles are all 97%. These high removal efficiencies of each pollutant due to adsorption and biological oxidation in activated carbon filter layer. The best backwashing method of two stage dual media filtration system is ascertained by air injection, air + water injection and water injection sequence. In this study, a pilot plant of two stage and dual filtration system was operated for 4 months in water treatment plant. The stability of turbidity was maintained below 1 NTU. The TOC, THMFP and HAAFP were removed about 90% by two stage and dual media filtration system, which is almost 2 times higher than existing water treatment plant.

Implementation of Digital CODEC for RFID Dual-band Reader system (RFID Dual-band 리더 시스템의 디지털 코덱 설계)

  • Sim, Jae-Hee;Lee, Yong-Joo;Lee, Yong-Surk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10A
    • /
    • pp.1015-1022
    • /
    • 2007
  • In this paper, dual-band digital codec for UHF(Ultra High Frequency) and MW(Micro Wave) is proposed for an RFID reader system. Most RFID systems have been supported only one protocol. But, There are many protocols of each bandwidth. Especially, UHF bandwidth which is widely used on the globe consists of A,B,C type, and more standards will be established. Recently, Since an interest about mobile RFID system is increasing, the RFID system with more than one protocol will be need. Therefore, this paper suggests a dual-band digital codec with UHF and MW bands for an RFID reader system. Standards used in this system are 18000-6C and 18000-4 standards. The digital codec is synthesize by the Quartus II compiler. Target device is EPC20Q240C8 which is family of CycloneII. Main Clock is 19.2MHz and elements of FPGA which is used for the system is 18,752.

The extension of marine lantern protocol for Dual LED marine lantern control system (이중 LED 등명기 제어 시스템을 위한 확장된 해상 등명기 프로토콜)

  • Ye, Seong-Hyeon;Kim, Bum-Khon;Park, Jeong-Seon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.445-451
    • /
    • 2014
  • Dual LED lantern, which is composed of two light sources in one lantern, can be utilized as an auxiliary light source when the main light source is in trouble. Nevertheless, there are no way to obtain status information of the system and control the light source if the current domestic standard protocol is applied, since the standards for dual LED lantern are not defined yet. Regarding to this problem, we suggested expanded lantern protocol for management system of dual LED lantern based on current domestic standard. Also, we confirmed the normal operation of dual LED lantern after implementing suggested protocol on the developed management system. Control system suggested and implemented in this study is tested not only its function of controlling and acquiring the operating status of dual LED lantern, but also its capability to utilize as a control system of currently used LED lanterns.

Verification of “dual-master” Duplication Flight Control System using Simulink Virtual Module (Simulink 가상모듈을 이용한 “dual-master” 이중구조 비행제어시스템 검증)

  • Kim, Sung-Su;Kim, Sung-Hwan;Jang, Se-Ah;Choi, Kee-Young;Park, Choon-Bae;Rhee, Ihn-Seok;Ha, Cheol-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.9
    • /
    • pp.867-873
    • /
    • 2008
  • Model based virtual Flight Control System construction is essential for Fly-by-Wire Flight Control System verification & validation(V&V) of concurrent engineering base. We researched the concept of dual-architecture system for virtual system construction, and analyzed Flight Control System that is applied to high altitude long endurance(HAE) UAS. Finally, we constructed the model based virtual Flight Control System with system analysis and achieved system verification about flight critical failure modes. Analysis target is RQ-4A.

Treatment of the Herniated Nucleus Pulposus Syndrome by Chemonucleolysis with Chymopapain

  • Dabezies, Eugene J.
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.111-120
    • /
    • 1984
  • A new restoration method of chest X-ray image (dual project filter) was proposed to improve SNR (signal to noise ratio) characteristics. In this method, a priori information of system and anatomical structure and statistics of projected object are used in the design of filter. Dual projection filter varies its parameters, adapting to the local regions of chest(lungregion, mediasternum, subdiaphragm) and the structure of chest (bone, tissue, blood vessel, bronchia). The performance of Dual Projection Filter was 0.1-0.2dB better than Dual Sensor Wiener Filter, which was used for initial estimate of Dual Porjection Filter.

  • PDF

PROPERTIES OF HYPERHOLOMORPHIC FUNCTIONS ON DUAL TERNARY NUMBERS

  • Jung, Hyun Sook;Shon, Kwang Ho
    • The Pure and Applied Mathematics
    • /
    • v.20 no.2
    • /
    • pp.129-136
    • /
    • 2013
  • We research properties of ternary numbers with values in ${\Lambda}(2)$. Also, we represent dual ternary numbers in the sense of Clifford algebras of real six dimensional spaces. We give generation theorems in dual ternary number systems in view of Clifford analysis, and obtain Cauchy theorems with respect to dual ternary numbers.

Independent MPP Tracking Method of Hybrid Solar-Wind Power Conditioning Systems Using Integrated Dual-Input Single-PWM-Cell Converter Topology

  • Thenathayalan, Daniel;Ahmed, Ashraf;Choi, Byung-Min;Park, Jeong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.790-802
    • /
    • 2017
  • This paper proposes the modeling and control strategy to track the MPPs of hybrid PV and Wind power systems, using a new dual input boost converter. The dual input power conditioning system with an independent MPPT control scheme is introduced with minimum number of circuit elements in order to reduce the switching loss, size and cost of the system. Since the operating conditions for the PV and Wind power systems are very distinct from each other, an efficient and superior control system is required to track the MPPs of both renewable sources with the use of a simply-structured single-ended single-inductor converter. The design of Power-Conditioning System (PCS) and detail control strategy are presented in this paper. To provide independent tracking of MPPs, a variable duty-cycle control strategy is employed for the wind system and a variable frequency strategy is employed for the PV system. Finally, the proposed dual-input converter for hybrid power conditioning system is implemented and the hardware test results are presented. From the hardware experiment, it is concluded that the proposed system successfully tracks the MPPs of both of the renewable power systems independently.

Long-term Stability Optimization of Dynamic Spectroscopic Ellipsometery based on Dual-wavelength Calibration (이중 파장 보정방법 기반 다이나믹 분광타원편광계의 안정도 최적화)

  • Choi, Inho;Kheiryzadehkhanghah, Saeid;Choi, Sukhyun;Hwang, Gukhyeon;Shim, Junbo;Kim, Daesuk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.178-183
    • /
    • 2021
  • This paper describes a dynamic spectroscopic ellipsometry based on dual-wavelength calibration. DSE provides ellipsometric parameters at rates above 20 Hz, but the interferometer's sensitivity to temperature makes it difficult for that proposed system to maintain stable 𝜟k over long periods of time. To solve this problem, we set up an additional path in the DSE to perform simulations of the polarization phase calibration method using dual wavelengths. Through simulation, we were able to eliminate most of the polarization phase error and maintain a stable 𝜟k in the long-term stability experiment for 10 hours. This is the result that the 𝜟k stability of the proposed system is improved tens of times compared to the existing system.