• Title/Summary/Keyword: Dual resonance

Search Result 182, Processing Time 0.024 seconds

Applied of Integrated Optical Biosensor based on Combination of Photonic Crystal Micro-Cavity and Ring Resonator (광결정 공진기와 링 공진기의 공진특성 결합을 통한 바이오센서 응용)

  • Kim, Hong-Seung;Kim, Doo-Gun;Oh, Geum-Yoon;Lee, Tae-Kyeong;Choi, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.817-822
    • /
    • 2011
  • We propose a novel ring structure based on the stadium-shaped ring resonator (SSRR) with dual photonic crystal microcavity (DPCM) for biosensor and analyzed the sensing characteristics. The Q-factor of the photonic crystal microcavity (PCM) can be significantly enhanced when the PCM or DPCM has the same resonance condition as the SSRR. The simulation results show that the Q-factor of the SRR with DPCM was increased by three times in comparison with single PCM structure. We also defined a mutual interference between two PCMs. Assuming a detectable spectral resolution of 10 picometers, a refractive index resolution of $3.03\times10-5$ can be measured on the SSRR-DPCM.

RF Measurements of the 2nd fabricated KAERI Dual Energy S-band Linac

  • Song, Gi-Baek;Park, Hyeong-Dal;Li, Yonggui;Cha, Seong-Su;Lee, Byeong-No;Kim, Yu-Jong;Lee, Byeong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.111.1-111.1
    • /
    • 2013
  • 전자가속기는 대표적인 방사선 발생장치 중의 하나로서, 오랜 세월 동안 연구개발 되어왔으며 의료 및 산업현장에서 활용되어 왔고 그 이용분야도 매우 폭넓다. 전자가속기는 최근 들어 기술이 확산되고 성능이 고도화되면서 그 활용과 함께 전자가속기 개발 및 연구가 많이 진행되고 있다. 이러한 연구개발에 있어 전자가속기의 가속관 제작은 가장 기본이 되는 중요한 부분 중에 하나이다. 가속관제작에 있어서 RF parameter들인 resonance frequency, bandwidth, 10 GHz 범위의 higher order modes와 quality factor는 가속관에서 중요한 특성이다. 본 연구에서는 9, 6 MeV 에너지를 가지는 2856 MHz의 고주파 전자가속기의 가속관 설계, 제작 및 튜닝에 있어서 network analyzer를 이용하여 RF parameter를 측정하여 가속관의 특성을 분석한다.

  • PDF

Troponin-Positive Non-Obstructive Coronary Arteries and Myocardial Infarction with Non-Obstructive Coronary Arteries: Definition, Etiologies, and Role of CT and MR Imaging

  • Seung Min Yoo;Sowon Jang;Jeong A Kim;Eun Ju Chun
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1305-1316
    • /
    • 2020
  • In approximately 10% of patients with acute myocardial infarction (MI), angiography does not reveal an obstructive coronary stenosis. This is known as myocardial infarction with non-obstructive coronary arteries (MINOCA), which has complex and multifactorial causes. However, this term can be confusing and open to dual interpretation, because MINOCA is also used to describe patients with acute myocardial injury caused by ischemia-related myocardial necrosis. Therefore, with regards to this specific context of MINOCA, the generic term for MINOCA should be replaced with troponin-positive with non-obstructive coronary arteries (TpNOCA). The causes of TpNOCA can be subcategorized into epicardial coronary (causes of MINOCA), myocardial, and extracardiac disorders. Cardiac magnetic resonance imaging can confirm MI and differentiate various myocardial causes, while cardiac computed tomography is useful to diagnose the extracardiac causes.

Anomalous Origin of the Coronary Artery from the Pulmonary Artery in Children and Adults: A Pictorial Review of Cardiac Imaging Findings

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1441-1450
    • /
    • 2021
  • Anomalous origin of the coronary artery from the pulmonary artery is a rare and potentially fatal congenital heart defect. Up to 90% of infants with an anomaly involving the left coronary artery die within the first year of life if left untreated. Patients who survive beyond infancy are at risk of sudden cardiac death. Cardiac CT and MRI are increasingly being used for the accurate diagnosis of this anomaly for prompt surgical restoration of the dual coronary artery system. Moreover, life-long imaging surveillance after surgery is necessary for these patients. In this pictorial review, multimodal cardiac imaging findings of this rare and potentially fatal coronary artery anomaly are comprehensively discussed, and representative images are provided to facilitate the understanding of this anomaly.

Design and Implementation of Single-Feed Dual-Band Circular Polarization Triangular Antenna for Reception of GPS and DMB Signals (GPS와 DMB 신호 수신을 위한 단일 급전 이중 대역 원형 편파 삼각 패치 안테나 설계 및 구현)

  • Lee, Won-Kew;Kim, Sung-Min;Yang, Woon-Gen
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.9 s.100
    • /
    • pp.893-902
    • /
    • 2005
  • We propose a novel single-feed triangular patch antenna with bar-type slots for dual-band circular polarization operation. And also propose a H-type slotted triangular patch antenna to enhance the ratio of the resonance frequencies. 3 cases of desist examples with bar-type slots were investigated and also 4 cases of H-slotted antennas were investigated to meet the dual-band requirement for GPS(Global Positioning System) and DMB(Digital Multimedia Broadcasting). One suitable design example was implemented and measured. Simulation results of the design example for GPS and DMB system show that axial ratio and maximum gain are 3.80 dB, 8.85 dBi for low-band at 1.575 GHz and 2.02 dB, 8.60 dBi for high-band at 2.642 GHz, respectively. Measured results of the implemented antenna show that $S_{11}$ is -12.43 dB for low-band at 1.575 GHz and less than -18.75 dB for high-band, respectively.

Dual-Band Six-Port Direct Conversion Receiver with I/Q Mismatch Calibration Scheme for Software Defined Radio (Software Defined Radio를 위한 I/Q 부정합 보정 기능을 갖는 이중 대역 Six-Port 직접변환 수신기)

  • Moon, Seong-Mo;Park, Dong-Hoon;Yu, Jong-Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.651-659
    • /
    • 2010
  • In this paper, a new six-port direct conversion receiver for high-speed multi-band multi-mode wireless communication system such as software defined radio(SDR) is proposed. The designed receiver is composed of two CMOS four-port BPSK receivers and a dual-band one-stage polyphase filter for quadrature LO signal generation. The four-port BPSK receiver, implemented in 0.18 ${\mu}m$ CMOS technology for the first time in microwave-band, is composed of two active combiners, an active balun, two power detector, and an analog decoder. The proposed polyphase filter adopt type-I architecture, one-stage for reduction of the local oscillator power loss, and LC resonance structure instead of using capacitor for dual-band operation. In order to extent the operation RF bandwidth of the proposed six-port receiver, we include I/Q phase and amplitude calibration scheme in the six-port junction and the power detector. The calibration range of the phase and amplitude mismatch in the proposed calibration scheme is 8 degree and 14 dB, respectively. The validity of the designed six-port receiver is successfully demonstrated by modulating M-QAM, and M-PSK signal with 40 Msps in the two-band of 900 MHz and 2.4 GHz.

Antenna-Diplexer Module for Cellular/SDMB Band Using LTCC Technology (LTCC 공법을 사용한 Cellular/SDMB 안테나-다이플렉서 모듈)

  • Ha, Jeung-Uk;Chang, Ki-Hun;Yoon, Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.774-783
    • /
    • 2007
  • This paper presents an integrated packaging antenna-diplexer module for wireless communication systems in the Cellular and SDMB band. The design and the realization of the proposed one are experimentally analyzed and discussed. It consists of a dual-resonance antenna and a diplexer with a multi-layer LTCC(${\varepsilon}_r=7.8,\;tan\;{\delta}=0.0043$) technology with integration capability and low loss. The dual-resonance antenna of the proposed module has the meander line structure for size reduction and has the shorting structure of an inverted F antenna to achieve good impedance matching. The diplexer of the proposed module was designed with the combination of low pass filter(LPF) and high pass filter(HPF). Decreasing the mutual interference between them provides a high isolation characteristic. The proposed antenna-diplexer module with dimensions of $27.5{\times}12.0{\times}2.2mm$ operates within a range from 813 MHz to 902 MHz for the cellular band and from 2,586 MHz to 2,655 MHz for the SDMB band. And the measured gain of the fabricated module is -1.96 dBi for Cellular band and -5.43 dBi for SDMB band. The parameters for the antenna-diplexer module are investigated and the several performances are discussed.

A Design of Wide-Band PIFA for 700 MHz LTE Band (700 MHz 대역 LTE용 광대역 PIFA 설계)

  • Park, Chan-Jin;Min, Kyoeng-Sik;Kim, Jeong-Won;An, Seong-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.328-334
    • /
    • 2012
  • This paper proposes a design technique of wide-band antenna for handy phone with 700 MHz LTE(Long Term Evolution) low frequency bandwidth. The proposed antenna based on the PIFA(Planar Inverted-F type Antenna) structure was designed and considered. In order to realize the wide bandwidth, a round structure which is able to control the electric path length of current and a branch line element which can be obtain the dual resonance characteristics were introduced in this design. As a result, It was realized about 95 MHz bandwidth in spite of very small space of $30{\times}34mm$ used for FR-4 substrate with relative permitivity of 4.4 at 700 MHz band. Measurement results of return loss, bandwidth and gain radiation pattern were agreed well with their calculation results.

Dual-wide-band absorber of truncated-cone structure, based on metamaterial

  • Kim, Y.J.;Yoo, Y.J.;Rhee, J.Y.;Kim, K.W.;Park, S.Y.;Lee, Y.P.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.235.1-235.1
    • /
    • 2015
  • Artificially-engineered materials, whose electromagnetic properties are not available in nature, such as negative reflective index, are called metamaterials (MMs). Although many scientists have investigated MMs for negative-reflective-index properties at the beginning, their interests have been extended to many other fields comprising perfect lenses. Among various kinds of MMs, metamaterial absorbers (MM-As) mimic the blackbody through minimizing transmission and reflection. In order to maximize absorption, the real and the imaginary parts of the permittivity and permeability of MM-As should be adjusted to possess the same impedance as that of free space. We propose a dual-wide-band and polarization-independent MM-A. It is basically a triple-layer structure made of metal/dielectric multilayered truncated cones. The multilayered truncated cones are periodically arranged and play a role of meta-atoms. We realize not only a wide-band absorption, which utilizes the fundamental magnetic resonances, but also another wide-band absorption in the high-frequency range based on the third-harmonic resonances, in both simulation and experiment. In simulation, the absorption bands with absorption higher than 90% are 3.93 - 6.05 GHz and 11.64 - 14.55 GHz, while the experimental absorption bands are in 3.88 - 6.08 GHz and 9.95 - 13.84 GHz. The physical origins of these absorption bands are elucidated. Additionally, it is also polarization-independent because of its circularly symmetric structures. Our design is scalable to smaller size for the infrared and the visible ranges.

  • PDF

Performance Improvement of Isolated High Voltage Full Bridge Converter Using Voltage Doubler

  • Lee, Hee-Jun;Shin, Soo-Cheol;Hong, Seok-Jin;Hyun, Seung-Wook;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2224-2236
    • /
    • 2014
  • The performance of an isolated high voltage full bridge converter is improved using a voltage doubler. In a conventional high voltage full bridge converter, the diode of the transformer secondary voltage undergoes a voltage spike due to the leakage inductance of the transformer and the resonance occurring with the parasitic capacitance of the diode. In addition, in the phase shift control, conduction loss largely increases from the freewheeling mode because of the circulating current. The efficiency of the converter is thus reduced. However, in the proposed converter, the high voltage dual converter consists of a voltage doubler because the circulating current of the converter is reduced to increase efficiency. On the other hand, in the proposed converter, an input current is distributed when using parallel input / serial output and the output voltage can be doubled. However, the voltages in the 2 serial DC links might be unbalanced due to line impedance, passive and active components impedance, and sensor error. Considering these problems, DC injection is performed due to the complementary operations of half bridge inverters as well as the disadvantage of the unbalance in the DC link. Therefore, the serial output of the converter needs to control the balance of the algorithm. In this paper, the performance of the conventional converter is improved and a balance control algorithm is proposed for the proposed converter. Also, the system of the 1.5[kW] PCS is verified through an experiment examining the operation and stability.