• Title/Summary/Keyword: Dual phase

Search Result 840, Processing Time 0.033 seconds

Mixed Dual-rail Data Encoding Method Proposal and Verification for Low Power Asynchronous System Design (저전력 비동기식 시스템 설계를 위한 혼합형 dual-rail data encoding 방식 제안 및 검증)

  • Chi, Huajun;Kim, Sangman;Park, Jusung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.96-102
    • /
    • 2014
  • In this paper, we proposed new dual-rail data encoding that mixed 4-phase handshaking protocol and 2-phase handshaking protocol for asynchronous system design to reduce signal activities and power consumption. The dual-rail data encoding 4-phase handshaking protocol should leat to much signal activities and power consumption by return to space state. Ideally, the dual-rail data encoding 2-phase handshaking protocol should lead to faster circuits and lower power consumption than the dual-rail 4-phase handshaking protocol, but can not designed using standard library. We use a benchmark circuit that contains a multiplier block, an adder block, and latches to evaluate the proposed dual-rail data encoding. The benchmark circuit using the proposed dual-rail data encoding shows an over 35% reduction in power consumption with 4-phase dual-rail data encoding.

A Design of Dual-Phase Instructions for a effective Logarithm and Exponent Arithmetic (효율적인 로그와 지수 연산을 위한 듀얼 페이즈 명령어 설계)

  • Kim, Chi-Yong;Lee, Kwang-Yeob
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.64-68
    • /
    • 2010
  • This paper proposes efficient log and exponent calculation methods using a dual phase instruction set without additional ALU unit for a mobile enviroment. Using the Dual Phase Instruction set, it extracts exponent and mantissa from expression of floating point and calculates 24bit single precision floating point of log approximation using the Taylor series expansion algorithm. And with dual phase instruction set, it reduces instruction excution cycles. The proposed Dual Phase architecture reduces the performance degradation and maintain smaller size.

Influence of pH in 3.5% NaCl aqueous solution on corrosion fatigue-fracture of dual phase steel (3.5% NaCl 수용액의 pH변화가 복합조직강의 부식피로파괴에 미치는 영향)

  • 오세욱;안호민;도영문
    • Journal of Ocean Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.123-129
    • /
    • 1987
  • Corrosion fatigue fracture of dual phase steel(SS41) and raw material steel(SS41) were investigated in 3.5% NaCl aqueous solution at PH 4,6,9 and 11. The fatigue limit of dual phase steel is increased approximately 1.8 times larger than that of raw material in air. The corrosion fatigue life of dual phase steel is about 5-10 times larger than that of raw material in 3.5% NaCl aqueous solution. The reduction of fatigue life is larger for the acidsalt solution than for the alkali salt solution. The reduction of stress level on the reduction ratio of corrosion fatigue life is large as pH 6-11. The reduction ratio of corrosion fatigue life of dual phase steel and raw material is nearly coincided at pH 2. While at pH4-2 the reduction ratio of corrosion fatigue life only depends on the corrosion effect. It has been found that the corrosion resistance effect of dual phase steel is smaller than that of raw material in corrosion fatigue crack propagation rate. As pH below 6 is changed, it can be clearly observed from raw material that the brittle intergranular fracture is characterized, and from the above result, the influence of corrosion of dual phase steel is small.

  • PDF

Investigation of Winding Connections for Fault-Tolerant of MW Class Offshore Wind Generator with Dual 3-Phase System and Modular (이중 3상 시스템과 모듈러를 갖는 MW급 해상용 풍력발전기의 무정지 기능을 위한 권선 체결방식에 관한 연구)

  • Seo, Jang Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1108-1114
    • /
    • 2013
  • This paper presents a new winding topology for MW class offshore wind generator having modular and dual 3-phase. Based on proposed simplified relationship between magnetic flux and phase current in the air gap, several new windings for modular and dual 3-phase are made. In case of one inverter operation or faulty operation, the proposed model can have balanced 3-phase induced voltage whereas the conventional generator with modular winding has unbalanced induced voltage, which can be important issue in offshore generator. The model was applied into 6MW prototype machine with dual 3-phase. Using finite element analysis, induced voltage, inductance were investigated. The results show that the proposed modular winding can be applicable to dual inverter system with electrically balanced voltage.

Analysis of Strain Distribution According to Change in the Vacancy Shape of the Lightweight Dual-Phase Structure (경량화된 이중상 구조의 중공 형태 변화에 따른 변형률 분포 분석)

  • Lee, J.A.;Kim, Y.J.;Jeong, S.G.;Kim, H.S.
    • Transactions of Materials Processing
    • /
    • v.31 no.5
    • /
    • pp.267-272
    • /
    • 2022
  • A dual-phase structure refers to a material with two different phases of components or crystal structures. In this study, we analyze the stress distributions for harmonic and composite structured materials which are a kind of dual-phase structure materials. The finite element method (FEM) was used to progress compression test to analyze the strain distribution, and rather than constituted of a fully dense material, a dual-phase structure was designed to make a lightweight structure that has different shapes and volumes of vacancy in each case. As a result of each case, the dual-phase structured materials showed different stress distribution patterns and based on this, the cause was identified through the research.

A Efficient Calculation for log and exponent with A Dual Phase Instruction Architecture (효율적인 로그와 지수 연산을 위한 듀얼 페이즈 명령어 구조)

  • Kim, Jun-Seo;Lee, Kwang-Yeob;Kwak, Jae-Chang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.320-323
    • /
    • 2010
  • This paper proposes efficient log and exponent calculation methods using a dual phase instruction set without additional ALU unit for a mobile enviroment. Using the Dual Phase Instruction set, it extracts exponent and mantissa from expression of floating point and calculates 24bit single precision floating point of log approximation using the Taylor series expansion algorithm. And with dual phase instruction set, it reduces instruction excution cycles. The proposed Dual Phase architecture reduces the performance degradation and maintain smaller size.

  • PDF

Microstructure and deformation behavior of nanostructured dual-phase steel (나노 결정립 이상 조직강의 미세조직 및 변형거동)

  • Ko, Y.G.;Lee, K.M.;Lee, C.W.;Kum, D.H.;Shin, D.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.445-448
    • /
    • 2009
  • The present work deals with microstructure and tensile deformation of nanostructured dual-phase steel consisting of ferrite and martensite phases. Prior to deformation, a fully martensite phase is prepared and then processed by equal channel angular pressing (ECAP) and subsequent annealing. Room-temperature tensile properties are examined and compared to those of dual-phase steels with coarse grains. Due to the combined effects coming from the grain refinement of both phases and their uniform distributions, the nanostructured dual-phase steel exhibits better strength and ductility than coarse grained counterpart, achieving ${\sim}1\;GPa$ and ${\sim}20%$ for tensile strength and elongation, respectively.

  • PDF

Influence of Notch Change on Corrosion Fatigue Fracture in F.E.M. Dual phase Steel of SS41 Steel (SS41강의 F.E.M.복합조직강에서 노치변화가 부식피로파괴에 미치는 영향)

  • 도영민;이규천
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.44-50
    • /
    • 2001
  • The rotated bending fatigue test was conducted in air md in 3.5% NaCl salt solution to investigate the fatigue fracture behaviour of raw material and F.E.M dual phase steel made from raw material(SS41) by a suitable heat treatment. This study has compared the initial microcrack creation of material by tensile test with that by fatigue test. And the rotated bending test of cantilever type under the condition of 3.5% NaCl salt solution and air has investigated the corrosion fatigue fracture behaviour with the variation of stress concentration factor determined by each of notch shapes. The initial microcrack have been developed in fragile grainboundary with general corrosion occurring in raw material : in the pits built up by corrosion in F.E.M. dual phase steel because pits bring out stress concentration. It is small that the degree of decrease in corrosion fatigue life for F.E.M. dual phase steel compared with raw material because the notch sensitivity of F.E.M. dual phase steel is lower than raw material in reason of characteristics with two-phase construction.

  • PDF

New Configuration of a PLDRO with an Interconnected Dual PLL Structure for K-Band Application

  • Jeon, Yuseok;Bang, Sungil
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.3
    • /
    • pp.138-146
    • /
    • 2017
  • A phase-locked dielectric resonator oscillator (PLDRO) is an essential component of millimeter-wave communication, in which phase noise is critical for satisfactory performance. The general structure of a PLDRO typically includes a dual loop of digital phase-locked loop (PLL) and analog PLL. A dual-loop PLDRO structure is generally used. The digital PLL generates an internal voltage controlled crystal oscillator (VCXO) frequency locked to an external reference frequency, and the analog PLL loop generates a DRO frequency locked to an internal VCXO frequency. A dual loop is used to ease the phase-locked frequency by using an internal VCXO. However, some of the output frequencies in each PLL structure worsen the phase noise because of the N divider ratio increase in the digital phase-locked loop integrated circuit. This study examines the design aspects of an interconnected PLL structure. In the proposed structure, the voltage tuning; which uses a varactor diode for the phase tracking of VCXO to match with the external reference) port of the VCXO in the digital PLL is controlled by one output port of the frequency divider in the analog PLL. We compare the proposed scheme with a typical PLDRO in terms of phase noise to show that the proposed structure has no performance degradation.

A Study on Strain-Void Growth Mechanism of Dual Phase Steel by Statistical Method (통계적 방법을 이용한 복합조직강의 변형률과 보이드 성장거동에 관한 연구)

  • 오경훈;유용석;오택열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.533-538
    • /
    • 2000
  • Ductile fracture of dual phase steel begins with void nucleation, at martensite-ferrite interface of deformed martensite particle. In this study, void nucleation, growth, and coalescence under various strain were studied in dual phase steel. Therefore, by means of the heat treatment of low carbon steel, the study deals with void nucleation and growth for ferrite grain size and martensite volume fraction of dual phase steel using statistical method. Void nucleation and growth with increasing strain are shown depend upon the ferrite grain size. Voids volume fraction generally increase as ferrite grain size decease.

  • PDF