• 제목/요약/키워드: Dual current control

검색결과 210건 처리시간 0.025초

전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘 (Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions)

  • 송승호;김정재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

철도 직류 급전용 싸이리스터 이중 컨버터 전력 시스템의 병렬운전 기법 (Parallel Control Algorithm of Thyristor Dual Converter Power System for DC Power Substation of Railway)

  • 김영우;문동옥;이창희
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.9-17
    • /
    • 2017
  • A parallel control algorithm of thyristor dual-converter power system for the DC power supply of railway is proposed. The circulating current and current imbalance generated during parallel operation can be limited to control the output voltage of each power system by using the proposed parallel control algorithm. The proposed control algorithm can also eliminate output current sensor to achieve the same output response without additional costs. The validity of the proposed algorithm is verified through simulation and experiment.

수정된 강제 유도 운동치료와 결합된 이중 반구 경두개 직류 자극이 만성 뇌졸중의 팔 기능에 미치는 영향 : 단일 맹검 무작위 통제 시험 (Impact of Dual-Hemisphere Transcranial Direct Current Stimulation Combined with Modified Constraint-Induced Movement Therapy on Upper Limb Function in Chronic Stroke: A Single Blinded Randomized Controlled Trial)

  • 김선호
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.11-20
    • /
    • 2020
  • Purpose : The purpose of this study was to research the effects of dual-hemisphere transcranial direct current stimulation (dual tDCS) and modified constraint-induced movement therapy (mCIMT) to improve upper extremity motor function after stroke. Methods : The study period was from August 2019 to November 2019, and included 24 patients who met the selection criteria. Participants were divided into 2 groups: dual tDCS and mCIMT, and sham dual tDCS and mCIMT group. Dual tDCS and mCIMT group performed mCIMT immediately after applying dual tDCS for 20 minutes, and sham dual tDCS and mCIMT group performed mCIMT immediately after applying sham tDCS for 20 minutes without turning on the power source. Total interventions were conducted 5 times per week for 4 weeks, and mCIMT was conducted for 30 minutes per session for both experimental and control groups. Fugl-Meyer assessment (FMA) and Motor Activity Log scale (MAL) were analyzed before and after 4 weeks of intervention. Results : Both experimental and control groups showed significant changes in FMA, Amount of Use (AOU), and Quality of Movement (QOM) of MAL. When the differences between groups was compared using ANCOVA, the experimental group showed a greater improvement in FMA and AOU of MAL than the control group. Conclusion : In order to enhance the effect of improving upper limb function of stroke patients, dual tDCS could be applied to provide more effective treatment in the clinical setting. Further studies will be needed in larger groups of stroke patients, including long-term follow-up, and multi-group comparisons through the establishment of anodal tDCS and mCIMT, cathodal tDCS, and mCIMT groups to clarify the effects of dual tDCS. In addition, research is needed to establish a protocol for tDCS, and this evidence-based intervention protocol is expected to be used in the clinical setting as an interventional method for various purposes.

단전원 듀얼 인버터의 데드타임으로 인한 영상전류 억제 방법 (Suppression of Zero Sequence Current Caused by Dead-time for Dual Inverter With Single Source)

  • 윤범렬;김태형;이준희;이준석
    • 전력전자학회논문지
    • /
    • 제27권2호
    • /
    • pp.126-133
    • /
    • 2022
  • This study proposes a suppression of zero sequence current (ZSC), which is caused by zero sequence voltage (ZSV) for a dual two-level inverter with single DC bus. Large output voltages enable the dual inverter with single DC bus to improve a system efficiency compared with single inverter. However, the structure of dual inverter with single DC bus inevitably generates ZSC, which reduces the system efficiency and causes a current ripple. ZSV is also produced by dead time, and its magnitude is determined by the DC bus and current direction. This study presents a novel space vector modulation method that allows the instantaneous suppression of ZSC. Based on a condition where a switching period is twice a sampling (control) period, the proposed control method is implemented by injecting the offset voltage at the primary inverter. This offset voltage is injected in half of the switching period to suppress the ZSC. Simulation and experiments are used to compare the proposed and conventional methods to determine the ZSC suppression performance.

Design of Dual-channel Interleaved Phase-shift Full-bridge Converter

  • Che, Yanbo;Wang, Dianmeng;Liu, Xiaokun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1529-1536
    • /
    • 2017
  • A digital dual-channel interleaved phase-shift full-bridge converter is investigated in this paper, and its topology and principle are analyzed. To realize current sharing and stabilize the output voltage, a controller with current sharing loop and closed voltage loop is employed. In addition, current sharing will increase the output current fluctuation and a new digital interleaved driving technology is proposed to reduce the output current ripple. To verify the analysis, simulation and experiments are carried out, which shows the effectiveness of the proposed control strategies.

PFC Dual Boost Converter Based on Input Voltage Estimation for DC Inverter Air Conditioner

  • Park, Gwi-Geun;Kwon, Kee-Yong;Kim, Tae-Woong
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.293-299
    • /
    • 2010
  • In this paper, a single-phase PFC (Power Factor Correction) dual boost converter based on input voltage estimation is studied for DC inverter air conditioner. It is focused on improving input power factor and power quality to satisfy the recent harmonic current regulation standards. Furthermore the input voltage estimation is introduced for price competitive products. A low cost and reasonable control system is implemented using a specified high-speed 32-bit microprocessor. Their effectiveness are verified through theoretical analysis and experiments.

Minimize Reactive Power Losses of Dual Active Bridge Converters using Unified Dual Phase Shift Control

  • Wen, Huiqing;Su, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.654-664
    • /
    • 2017
  • This paper proposed an unified dual-phase-shift (UDPS) control for dual active bridge (DAB) converters in order to improve efficiency for a wide output power range. Different operating modes of UDPS are characterized with respect to the reactive current distribution. The proposed UDPS has the same output power capability with conventional phase-shift (CPS) method. Furthermore, its implementation is simple since only the change of the leading phase-shift direction is required for different operating power range. The proposed UDPS control can minimize both the inductor rms current and the circulating reactive current for various voltage conversion ratios and load conditions. The optimal phase-shift pairs for two bridges of DAB converter are derived with respect to the comprehensive reactive power loss model, including the reactive components delivered from the load and back to the source. Simulation and experimental results are illustrated and explained with details. The effectiveness of the proposed method is verified in terms of reactive power losses minimization and efficiency improvement.

도시 철도용 사이리스터 듀얼 컨버터 시스템의 3병렬 운전 제어 기법에 관한 연구 (A Study on Three Parallel Operation Control Algorithm of Thyristor Dual Converter System for Urban Railway Substation)

  • 김성안;한성우;조윤현
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.459-467
    • /
    • 2017
  • An urban railway power substation consists of three thyristor dual converters. Two converters are connected to up and down trolley line to supply the electric energy or feed the regenerative energy back to the distribution. When the two converters break down, the remaining converter is used in an emergency. One thyristor dual converter system (TDCS) manages the energy of two or three railway stations. If the TDCS fails, the trains stop operating. To solve the problem, this paper proposes the three parallel operation control algorithm of thyristor dual converter system using the emergency converter. The broken TDCS can be replaced by the emergency converter in other TDCS. The effectiveness of this proposed control is verified by simulation.

Parallel Sensorless Speed Control using Flux-axis Current for Dual SPMSMs Fed by a Single Inverter

  • Kim, Chang-Bum;Yun, Chul;Yoon, Byung-Keun;Cho, Nae-Soo;Kwon, Woo-Hyen
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1048-1057
    • /
    • 2015
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors (SPMSMs) fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position; consequently, the position sensor is deemed essential for finding the rotor position. The parallel sensorless speed control method proposed in this paper uses no position sensor, instead it compares the flux-axis current from the connection between the back-EMF for torque angle and current in unbalanced load conditions. The results of simulation and experiment conducted verify the efficacy of the proposed method.

상간 리액터를 제거한 12상 병렬 연결 듀얼 컨버터 시스템의 예측전류제어 (Predictive Current Control of 12-Pulse Parallel Connected Dual Converter System without Interphase Reactors)

  • 박기태;지준근;설승기;최창호;신현석;이창원;장계용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.482-485
    • /
    • 1996
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system without interphase reactors(IPR) is presented. Firstly, the characteristics of system without IPR are analyzed and compared with that of system with IPR. And the predictive current control of this system is discussed. Finally the validity of the presented system and the excellence of the predictive current control response is proved through the simulation results.

  • PDF