• 제목/요약/키워드: Dual compressor

검색결과 23건 처리시간 0.021초

냉장 차량용 듀얼 컴프레서 인버터 시스템 (Dual Compressor Inverter System for Refrigerator Vehicles)

  • 한근우;김성곤;이충훈;최명현;정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.292-293
    • /
    • 2017
  • In the single type mechanical compressor mounted on the refrigerated vehicle, one compressor is responsible for the refrigerator function of the air conditioner and the refrigerator, so it is difficult to maintain a certain refrigeration temperature in the summer. Particularly, in a mechanical compressor using an engine as a power source, the refrigeration quality is deteriorated due to unstable rotation of the engine. In this paper, we propose a three - phase inverter of a dual compressor system that uses an electric compressor separately from a mechanical compressor of a refrigerated vehicle. The output characteristics of the developed inverter were verified through a vehicle air conditioning simulator.

  • PDF

이중용량 왕복동 압축기 신뢰성 확보에 대한 연구 (A Study on the Reliability of a Dual Capacity Reciprocating Compressor)

  • 김종봉
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.81-90
    • /
    • 2009
  • Due to environmental issues, the development of low energy consumption products has become one of the main topics in the home appliance industry. The energy consumption of a refrigerator depends on the efficiency of its compressor as well as on the refrigerator cycle design, such as the capacity modulation. In this study, a dual capacity, i.e., two-step capacity modulation (TCM), reciprocating compressor is developed. In a TCM compressor, capacity modulation is achieved by changing the dead volume in the cylinder. Instead of a concentric sleeve, an eccentric sleeve, a key, and a spring are used to change the dead volume for the clockwise and counterclockwise rotation of a motor. When the compressor changes its operating mode from full capacity to partial capacity or in opposite direction, the key may collide with the eccentric sleeve. The structural reliability and mode change reliability were confirmed by analysis and experiment.

A Dual-Servo Type VCM for a Nano-Level Measurement System

  • Yoo, Yong-Min;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.50-54
    • /
    • 2007
  • In this paper, a dual-servo type VCM (Voice Coil Motor) for the measuring of nano-level displacement and small thrust is proposed and developed. The shape of VCM for improving the resolution of displacement and ensuring a large displacement are presented. The FEM (finite element method) is utilized to analyze the characteristics of VCM that produces linear driving thrust and satisfies the thrust that the measurement system requires. The Prototype is fabricated and an experiment is performed in order to measure displacement. As a result of simulation and testing, the proposed VCM shows the applicable possibility for a nano-level measurement system.

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

신경망무고장모델과 이중퍼지로직을 사용한 냉방기 고장진단 알고리즘 (Fault Diagnosis Algorithm of an Air-conditioning System by using a Neural No-fault Model and a Dual Fuzzy Logic)

  • 한도영;정남철
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.791-799
    • /
    • 2006
  • The fault diagnosis technologies may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this paper, a fault diagnosis algorithm was developed by using a neural no-fault model and a dual fuzzy logic. Five different faults, such as the compressor valve leakage, the liquid line blockage, the condenser fouling, the evaporator fouling, and the refrigerant leakage of an air-conditioning system, were considered. The fault diagnosis algorithm was tested by using a fault simulation facility. Test results showed that the algorithm developed for this study was effective to detect and diagnose various faults. Therefore, this algorithm may be practically used for the fault diagnosis of an air-conditioning system.

블레이드 손상에 따른 이축식 터보팬 엔진의 동적 안정성 해석 (Rotordynamic Analysis of a Dual-Spool Turbofan Engine with Focus on Blade Defect Events)

  • 김시태;정기현;이준호;박기현;양광진
    • Tribology and Lubricants
    • /
    • 제36권2호
    • /
    • pp.105-115
    • /
    • 2020
  • This paper presents a numerical study on the rotordynamic analysis of a dual-spool turbofan engine in the context of blade defect events. The blades of an axial-type aeroengine are typically well aligned during the compressor and turbine stages. However, they are sometimes exposed to damage, partially or entirely, for several operational reasons, such as cracks due to foreign objects, burns from the combustion gas, and corrosion due to oxygen in the air. Herein, we designed a dual-spool rotor using the commercial 3D modeling software CATIA to simulate blade defects in the turbofan engine. We utilized the rotordynamic parameters to create two finite element Euler-Bernoulli beam models connected by means of an inter-rotor bearing. We then applied the unbalanced forces induced by the mass eccentricities of the blades to the following selected scenarios: 1) fully balanced, 2) crack in the low-pressure compressor (LPC) and high pressure compressor (HPC), 3) burn on the high-pressure turbine (HPT) and low pressure compressor, 4) corrosion of the LPC, and 5) corrosion of the HPC. Additionally, we obtained the transient and steady-state responses of the overall rotor nodes using the Runge-Kutta numerical integration method, and employed model reduction techniques such as component mode synthesis to enhance the computational efficiency of the process. The simulation results indicate that the high-vibration status of the rotor commences beyond 10,000 rpm, which is identified as the first critical speed of the lower speed rotor. Moreover, we monitored the unbalanced stages near the inter-rotor bearing, which prominently influences the overall rotordynamic status, and the corrosion of the HPC to prevent further instability. The high-speed range operation (>13,000 rpm) coupled with HPC/HPT blade defects possibly presents a rotor-case contact problem that can lead to catastrophic failure.

Performance Characteristics of a Household Refrigerator with Dual Evaporators Using Two-Stage Compression Cycle

  • Joo, Young-Ju;Kim, Young-Heon;Lee, Moo-Yeon;Yoon, Won-Jae;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권3호
    • /
    • pp.107-113
    • /
    • 2009
  • The objective of this study is to investigate performance characteristics of a household refrigerator using a two-stage compression cycle. The performance of the two-stage compression cycle was measured by varying the compressor speed, condensing temperature, and evaporating temperature. The COP of the two-stage compression cycle was analyzed and then compared with that of the single-stage compression cycle. The optimum combination of compressor speeds for a low- and a high-stage was determined. The COP of the two-stage compression cycle using a PTC (parallel two-stage compression) method was 5.85% higher than that of a STC (serial two-stage compression) method at optimum operating conditions.

Development of high capacity stirling cryocooler

  • Ko, Junseok;Yeom, Hankil;Kim, Hyobong;Hong, Yong-Ju;In, Sehwan;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.51-56
    • /
    • 2015
  • Cryogenic cooling system for HTS electric power devices requires a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has gamma-type configuration. Piston and displacer are supported with flexure spring. A slit-type heat exchanger is adopted for cold and warm-end, and the generated heat is rejected by cooling water. In cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. Moreover, temperatures of cooling water, housing and linear motor are recorded and electric power parameters of driving circuit are also obtained. The developed Stirling cryocooler reaches to 47.8 K within 23.4 min. with no-load. From heat load tests, it shows cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.

상용차 하이브리드 냉방시스템 냉방 성능 특성 연구 (Experimental study on cooling performance characteristics of hybrid refrigeration system in a heavy duty vehicle)

  • 이호성;전한별;김정일;이무연
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.419-425
    • /
    • 2019
  • 본 연구의 목적은 상용차 운행 시, 야간 및 운휴중에 냉방시스템을 운전하기 위하여서, 기계식과 전동식 압축기를 적용한 하이브리드 냉방시스템에 대한 냉방성능 특성을 분석하는 것이다. 기계식압축기는 170cc의 왕복동 형식이고, 전동식 압축기는 18cc 스크롤 형식이다. 전동식 압축기는 운휴시나 야간에 사용할 목적으로 적용되었기 때문에, 냉방용량은 기계식 압축기 대비 낮은 성능을 가지고 있다. 기계식 압축기를 사용하였을 경우, 6.0kW 수준의 냉방성능을 보이고 있고, 시스템 효율은 2.0이하의 결과를 가졌다. 반면, 전동식 압축기는 냉방성능 4.0kW수준, 시스템 효율은 3.5 수준을 가지고 있었다. 본 연구에서는 전동식 압축기는 냉방성능 4.0kW수준, 시스템 효율은 3.5 수준을 가지고 있었다. 기계식 압축기와 전동식 압축기를 운전조건에 따라서, 선택적으로 운전하는 것을 고려하였기 때문에, 운전모드가 바뀔 때의 시스템 특성을 분석하기 위하여서, 운전모드 변경에 대한 영향을 알아보았다. 운전모드가 변경될 때, 토출압력이 일시적으로 증가하는 경향을 보이는데, 안정적인 운전을 위하여서, 외기 부하 등을 고려한 운전모드 변경 로직에 대한 연구가 필요할 것으로 판단된다.

이젝터가 부착된 냉동시스템의 성능실험

  • 이원희;김윤조;김민수
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.993-1001
    • /
    • 2001
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were performed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one evaporator) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flaw rate ratio of suction fluid to motive fluid increases. The COP of dual-evaporator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

  • PDF