• 제목/요약/키워드: Dual X-ray

검색결과 361건 처리시간 0.033초

Development and validation of prediction equations for the assessment of muscle or fat mass using anthropometric measurements, serum creatinine level, and lifestyle factors among Korean adults

  • Lee, Gyeongsil;Chang, Jooyoung;Hwang, Seung-sik;Son, Joung Sik;Park, Sang Min
    • Nutrition Research and Practice
    • /
    • 제15권1호
    • /
    • pp.95-105
    • /
    • 2021
  • BACKGROUND/OBJECTIVES: The measurement of body composition, including muscle and fat mass, remains challenging in large epidemiological studies due to time constraint and cost when using accurate modalities. Therefore, this study aimed to develop and validate prediction equations according to sex to measure lean body mass (LBM), appendicular skeletal muscle mass (ASM), and body fat mass (BFM) using anthropometric measurement, serum creatinine level, and lifestyle factors as independent variables and dual-energy X-ray absorptiometry as the reference method. SUBJECTS/METHODS: A sample of the Korean general adult population (men: 7,599; women: 10,009) from the Korean National Health and Nutrition Examination Survey 2008-2011 was included in this study. The participants were divided into the derivation and validation groups via a random number generator (with a ratio of 70:30). The prediction equations were developed using a series of multivariable linear regressions and validated using the Bland-Altman plot and intraclass correlation coefficient (ICC). RESULTS: The initial and practical equations that included age, height, weight, and waist circumference had a different predictive ability for LBM (men: R2 = 0.85, standard error of estimate [SEE] = 2.7 kg; women: R2 = 0.78, SEE = 2.2 kg), ASM (men: R2 = 0.81, SEE = 1.6 kg; women: R2 = 0.71, SEE = 1.2 kg), and BFM (men: R2 = 0.74, SEE = 2.7 kg; women: R2 = 0.83, SEE = 2.2 kg) according to sex. Compared with the first prediction equation, the addition of other factors, including serum creatinine level, physical activity, smoking status, and alcohol use, resulted in an R2 that is higher by 0.01 and SEE that is lower by 0.1. CONCLUSIONS: All equations had low bias, moderate agreement based on the Bland-Altman plot, and high ICC, and this result showed that these equations can be further applied to other epidemiologic studies.

Fractal dimension analysis on CBCT scans for detecting low bone mineral density in postmenopausal women

  • Carvalho, Bruno Fontenele;de Castro, Julia Goncalves Koehne;de Melo, Nilce Santos;Figueiredo, Paulo Tadeu de Souza;Moreira-Mesquita, Carla Ruffeil;de Paula, Ana Patricia;Sindeaux, Rafael;Leite, Andre Ferreira
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.53-60
    • /
    • 2022
  • Purpose: The aim of this study was to compare the fractal dimension (FD) measured at 2 bone sites (second cervical vertebra and mandible) on cone-beam computed tomography (CBCT). The research question was whether FD could serve as an accessory tool to refer postmenopausal women for densitometric analysis. Therefore, the reliability and accuracy of FD were evaluated. Materials and Methods: In total, 103 postmenopausal women were evaluated, of whom 52 had normal bone mineral density and 51 had osteoporosis, according to dual X-ray absorptiometry of the lumbar spine and hip. On the CBCT scans, 2 regions of interest were selected for FD analysis: 1 at the second cervical vertebra and 1 located at the mandible. The correlations between both measurements, intra- and inter-observer agreement, and the accuracy of the measurements were calculated. A P value less than 0.05 was considered to indicate statistical significance for all tests. Results: The mean FD values were significantly lower at the mandibular region of interest in osteoporotic patients than in individuals with normal bone mineral density. The areas under the curve were 0.644 (P=0.008) and 0.531 (P=0.720) for the mandibular and vertebral sites, respectively. Conclusion: FD at the vertebral site could not be used as an adjuvant tool to refer women for osteoporosis investigation. Although FD differed between women with normal BMD and osteoporosis at the mandibular site, it demonstrated low accuracy and reliability.

Use of Dual-Energy X-ray Absorptiometry in Children with Inflammatory Bowel Disease: A Large Single Centre Study

  • Jois, Asha;Perera, Sajini;Simm, Peter;Alex, George
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제25권6호
    • /
    • pp.473-480
    • /
    • 2022
  • Purpose: Low bone mineral density (BMD) is a complication in children with inflammatory bowel disease (IBD). There are limited data evaluating dual-energy x-ray absorptiometry (DXA) as a screening tool for low BMD in children with IBD. We performed a single site retrospective analysis of DXA use. Methods: Children aged 5-18 years with IBD diagnosed between 2013 to 2017 at the Royal Children's Hospital, Australia, were included. Patient demographics, measures of disease activity, DXA scores, and factors related to BMD were collected. Results: Over a median follow up of 5.1 (4-6.4) years, 72/239 (30.1%) children underwent DXA, and 28/239 (11.7%) children had a second DXA. Our DXA practice differed to consensus guidelines regarding initial screening based on height and/or body mass index (BMI) z-score (8/17 [47.1%]), and repeat surveillance (13/42 [31.0%]). Children had a median lumbar spine (LS) z-score -0.80 (-1.65-0.075). Children with LS z-score≤-2.0 (n=14) had lower weight (6.57 [1.78-23.7] vs. 51.1 [26.5-68.7], p=0.0002) and height centiles (3.62 [1.17-17.1] vs. 42 [16.9-67.1], p=0.0001), and higher faecal calprotectin (FCP) (3041 [1182-4192] vs. 585 [139-2419], p=0.009) compared to children with LS z-score>-2.0. No fractures were reported. Of 28 children who underwent a second DXA 1.6 (1.1-2.2) years following initial DXA, no significant change in z-scores occurred. Conclusion: Children with IBD had low BMD. In addition to height centile and weight centile, FCP was associated with lower BMD, and should be considered in DXA screening guidelines. Greater clinician awareness of DXA consensus guidelines is required. Future prospective studies are required.

Determining the target strength bambood wrasse (Pseudolabrus japonicus) using Kirchhoff-ray mode

  • Kusdinar, Afriana;Hwang, Bo-Kyu;Shin, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제50권4호
    • /
    • pp.427-434
    • /
    • 2014
  • Although ex situ target strength (TS) measurements using dual- and split-beam systems have become the primary approach of estimating fish abundance, theoretical model estimation is a powerful tool for verifying the measurements, as well as for providing values when making direct measurements is difficult. TS values for 20 samples of live bambooleaf wrasse (Pseudolabrus japonicus) whose target length (TL) ranged between 13.7 and 21.3 cm were estimated theoretically using the Kirchhoff-ray mode model, and the TS values for 18 live fish samples were additionally measured at ${\sim}0^{\circ}$ tilt angle to the swimming aspect using a tethered method at a frequency of 120 kHz to verify the theoretical values. The digitizing intervals used to extract the fish body and swim bladder morphology in the X-ray photographs significantly affected the calculated TS patterns, but variations based on the speed of sound and density ratio values for the general range of fish flesh were relatively small (within 1 dB). Close agreement was observed between the measured and theoretical TS values, and the correlation between the average TS and body length of the fish could be calculated accurately as <$TS_{120kHz}$>= 20logTL (cm) -71.6 using the theoretical method.

The LaserFIB: new application opportunities combining a high-performance FIB-SEM with femtosecond laser processing in an integrated second chamber

  • Ben Tordoff;Cheryl Hartfield;Andrew J. Holwell;Stephan Hiller;Marcus Kaestner;Stephen Kelly;Jaehan Lee;Sascha Muller;Fabian Perez-Willard;Tobias Volkenandt;Robin White;Thomas Rodgers
    • Applied Microscopy
    • /
    • 제50권
    • /
    • pp.24.1-24.11
    • /
    • 2020
  • The development of the femtosecond laser (fs laser) with its ability to provide extremely rapid athermal ablation of materials has initiated a renaissance in materials science. Sample milling rates for the fs laser are orders of magnitude greater than that of traditional focused ion beam (FIB) sources currently used. In combination with minimal surface post-processing requirements, this technology is proving to be a game changer for materials research. The development of a femtosecond laser attached to a focused ion beam scanning electron microscope (LaserFIB) enables numerous new capabilities, including access to deeply buried structures as well as the production of extremely large trenches, cross sections, pillars and TEM H-bars, all while preserving microstructure and avoiding or reducing FIB polishing. Several high impact applications are now possible due to this technology in the fields of crystallography, electronics, mechanical engineering, battery research and materials sample preparation. This review article summarizes the current opportunities for this new technology focusing on the materials science megatrends of engineering materials, energy materials and electronics.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • 제27권1호
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Microcantilever biosensor: sensing platform, surface characterization and multiscale modeling

  • Chen, Chuin-Shan;Kuan, Shu;Chang, Tzu-Hsuan;Chou, Chia-Ching;Chang, Shu-Wei;Huang, Long-Sun
    • Smart Structures and Systems
    • /
    • 제8권1호
    • /
    • pp.17-37
    • /
    • 2011
  • The microcantilever (MCL) sensor is one of the most promising platforms for next-generation label-free biosensing applications. It outperforms conventional label-free detection methods in terms of portability and parallelization. In this paper, an overview of recent advances in our understanding of the coupling between biomolecular interactions and MCL responses is given. A dual compact optical MCL sensing platform was built to enable biosensing experiments both in gas-phase environments and in solutions. The thermal bimorph effect was found to be an effective nanomanipulator for the MCL platform calibration. The study of the alkanethiol self-assembly monolayer (SAM) chain length effect revealed that 1-octanethiol ($C_8H_{17}SH$) induced a larger deflection than that from 1-dodecanethiol ($C_{12}H_{25}SH$) in solutions. Using the clinically relevant biomarker C-reactive protein (CRP), we revealed that the analytical sensitivity of the MCL reached a diagnostic level of $1{\sim}500{\mu}g/ml$ within a 7% coefficient of variation. Using grazing incident x-ray diffractometer (GIXRD) analysis, we found that the gold surface was dominated by the (111) crystalline plane. Moreover, using X-ray photoelectron spectroscopy (XPS) analysis, we confirmed that the Au-S covalent bonds occurred in SAM adsorption whereas CRP molecular bindings occurred in protein analysis. First principles density functional theory (DFT) simulations were also used to examine biomolecular adsorption mechanisms. Multiscale modeling was then developed to connect the interactions at the molecular level with the MCL mechanical response. The alkanethiol SAM chain length effect in air was successfully predicted using the multiscale scheme.

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • 제35권5호
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

Optimization Study of Digital X-ray Imaging with Dual Energy Subtraction Method (듀얼 에너지 감산기법을 이용한 디지털 X-ray 영상 최적화에 관한 연구)

  • Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제53권10호
    • /
    • pp.138-142
    • /
    • 2016
  • Dual-energy digital radiography (DEDR) has been used for detecting lesions within the body using energy subtraction methods. The purpose of this study was to acquire optimal bone and tissue image by changing physical factors such as Tube voltage (kVp) and add filters, and then we compared with the predicted values using SRS-78 program and experimental results. For that purpose, we acquired images according to changes in physical parameters of various materials since we had to acquire the optimal bone and tissue image using energy subtraction. Used phantom consists of aluminum and polymethyl methacrylate (PMMA) and a comparison of image optimization was measured by contrast-to-noise ratio (CNR). In results, first of all, we confirmed that a subtraction image from 50 kVp image and 120 kVp image is optimal bone and tissue image. Also when we added a 10 mm Aluminum add filter, we expected it is a result of the optimal bone and tissue image. Besides, we confirmed these results are consistent with the predicted optimized condition by SRS-78 program.. In conclusion, we indicated that we can acquire optimal bone and tissue image by controling physical factors such as kVp, add filters through this study. Also we expected that DEDR will contribute to the field of medical imaging technology.

Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

  • Shota Tanoue;Takeshi Nakaura;Yasunori Nagayama;Hiroyuki Uetani;Osamu Ikeda;Yasuyuki Yamashita
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.951-958
    • /
    • 2021
  • Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.