• 제목/요약/키워드: Dual Exchanger

검색결과 24건 처리시간 0.031초

A Novel Induction Heating Type Super Heated Vapor Steamer using Dual Mode Phase Shifted PWM Soft Switching High Frequency Inverter

  • Sugimura, Hisayuki;Eid, Ahmad;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.774-777
    • /
    • 2005
  • In this paper, a constant frequency phase shifting PWM controlled voltage source full bridge-type series load resonant high-frequency inverter using the IGBT power modules is presented for innovative consumer electromagnetic induction heating applications such as a hot water producer, steamer and super heated steamer. The full bridge arm side link passive quasi-resonant capacitor snubbers in parallel with the each power semiconductor device and high frequency AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is discussed and evaluated on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency soft switching PWM inverter topology, what is called class DE type. including the variable-power variable-frequency(VPVF) regulation function can expand zero voltage soft switching commutation range even under low output power setting ranges, which is more suitable and acceptable for induction heated dual packs fluid heater developed newly for consumer power utilizations. Furthermore, even in the lower output power regulation mode of this high-frequency load resonant tank high frequency inverter circuit it is verified that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

  • PDF

Development of Induction Heater Hot Water System using New Active Clamping Quasi Resonant ZVS PWM Inverter

  • Kwon, Soon-Kurl;Mun, Sang-Pil
    • 조명전기설비학회논문지
    • /
    • 제22권11호
    • /
    • pp.23-29
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current based stainless steel plate spiral type heater for heat exchanger or dual packs heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamping quasi-resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated for a high efficient induction heated hot water system and boiler in the consumer power applications. This consumer induction heater power appliance using active clamping soft switching PWM high frequency inverter is evaluated and discussed on the basis of experimental results.

Development of Induction Heated Hot Water System using Soft Switching PWM High Frequency Inverter

  • Lee, Jong-Kurl;Mun, Sang-Pil;Park, Man-Kyu;Nakaoka, Mustsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.325-328
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or dual packs Heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamped quasi resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated fora high efficient induction heated hot water system and boiler in the consumer power applications This consumer induction heater power appliance using active clamp soft switching PWM high-frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

해수열원 히트펌프 시스템의 냉난방 운전 특성에 관한 실증 연구 (Experimental Study on the Cooling and Heating Operation Characteristics of a Sea Water Source Heat Pump)

  • 김지영;백영진;나호상;장기창
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.544-549
    • /
    • 2009
  • The purpose of this study is to investigate the field Operation Characteristics of a sea water heat source cascade heat pump system and system applicable to Building. Cascade heat pump system is composed R410A compressor, R134a compressor, EEV, cascade heat exchanger, Plate heat exchanger etc. Building area is $890m^2$ and has five floors above ground. R410A is used for a low-stage working fluid while R134a is for a high-stage. The system could runs at dual mode. One is mode of general R410A refrigeration cycle in summer and the other is cascade cycle. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. The filed test results show that the sea water heat source heat pump system exhibits a COP of about 5.5 in cooling mode along with a heating COP of about 4.0 in 1-stage heating mode. Cascade 2-stage heat pump system is enough to supply $60^{\circ}C$ water and heating COP is about 3.0

  • PDF

열교환기의 흐름개선을 통한 고효율 지열 히트펌프 시스템에 관한 연구 (A Study on High Efficiency Geothermal Heat Pump System by Improving Flow of Heat Exchanger)

  • 안성환;최재상;김상범;안형환
    • 한국가스학회지
    • /
    • 제21권4호
    • /
    • pp.42-46
    • /
    • 2017
  • 화석연료의 무분별한 사용으로 인한 이산화탄소의 대기 중 방출은 지구의 연평균 기온을 상승시키는 원인으로 작용하고 있다. 이를 해결하기 위한 대체에너지로써 지열은 연중 일정한 온도를 갖는 무한자원이다. 지열에너지를 널리 보급하기 위해서는 히트펌프의 성능과 지중열교환기의 열교환 효율이 매우 중요하다. 이에 본 연구는 히트펌프의 성능을 증가시키기 위해 팽창변을 이중으로 구성하고 지중열교환기의 열교환 효율을 높이기 위해 입출관과 유입관 사이에 간격유지부재를 사용하여 실험하였다. 실험한 결과 팽창변을 이중으로 구성하였을 때 냉난방 능력이 최대 11.4%가 증가됨을 얻을 수 있었고, 간격유지부재를 사용 시 열교환 효율이 17.5% 향상되었다. 이러한 결과를 토대로 지열시스템의 설치 시 히트펌프의 성능과 지중열교환기의 열교환 효율의 상승으로 인해 설치비용이 많이 절감될 것으로 판단된다.

엔진 폐열 회수를 위한 랭킨 스팀 사이클 설계 및 HT Boiler의 성능 평가 (Design of Rankine Steam Cycle and Performance Evaluation of HT Boiler for Engine Waste Heat Recovery)

  • 허형석;배석정;이동혁;이헌균;김태진
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.21-29
    • /
    • 2012
  • A dual loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop (HT loop) only recovers the heat of the exhaust gas. A low temperature loop (LT loop) recovers the residual heat from the HT loop, the coolant heat and the remaining exhaust gas heat. The two separate loops are coupled with a heat exchanger. This paper has dealt with a layout of the dual loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the HT boiler, a core part of a HT loop, have been presented. The prototype of the HT boiler was evaluated by experiment. For the performance evaluation of the HT boiler, inlet temperature of the HT boiler working fluid was set equal to the temperature degree of sub-cool of $5^{\circ}C$ at the condensing pressure. The exit condition was the degree of super-heat set at $5^{\circ}C$. The characteristics of the HT boiler such as heat recovery and pressure drops of fluids were evaluated with varying flow rates and inlet temperatures of exhaust gas under various evaporating pressure conditions.

Development of high capacity stirling cryocooler

  • Ko, Junseok;Yeom, Hankil;Kim, Hyobong;Hong, Yong-Ju;In, Sehwan;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.51-56
    • /
    • 2015
  • Cryogenic cooling system for HTS electric power devices requires a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has gamma-type configuration. Piston and displacer are supported with flexure spring. A slit-type heat exchanger is adopted for cold and warm-end, and the generated heat is rejected by cooling water. In cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. Moreover, temperatures of cooling water, housing and linear motor are recorded and electric power parameters of driving circuit are also obtained. The developed Stirling cryocooler reaches to 47.8 K within 23.4 min. with no-load. From heat load tests, it shows cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.

태양열을 이용한 일이중 겸용 흡수식 냉온수기 동적성능 모사연구 (A Study of Dynamic Simulation of a Hybrid Absorption Chiller Utilizing Solar Power)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.967-972
    • /
    • 2009
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector also were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flowrate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

  • PDF

일체형원자로의 신개념 안전계통 실증을 위한 실험적 연구 (Experimental Study on Design Verification of New Concept for Integral Reactor Safety System)

  • 정문기;최기용;박현식;조석;박춘경;이성재;송철화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2053-2058
    • /
    • 2004
  • The pressurized light water cooled, medium power (330 MWt) SMART (System-integrated Modular Advanced ReacTor) has been under development at KAERI for a dual purpose : seawater desalination and electricity generation. The SMART design verification phase was followed to conduct various separate effects tests and comprehensive integral effect tests. The high temperature / high pressure thermal-hydraulic test facility, VISTA(Experimental Verification by Integral Simulation of Transient and Accidents) has been constructed to simulate the SMART-P (the one fifth scaled pilot plant) by KAERI. Experimental tests have been performed to investigate the thermal-hydraulic dynamic characteristics of the primary and the secondary systems. Heat transfer characteristics and natural circulation performance of the PRHRS (Passive Residual Heat Removal System) of SMART-P were also investigated using the VISTA facility. The coolant flows steadily in the natural circulation loop which is composed of the steam generator (SG) primary side, the secondary system, and the PRHRS. The heat transfers through the PRHRS heat exchanger and ECT are sufficient enough to enable the natural circulation of the coolant.

  • PDF