• Title/Summary/Keyword: Dual Chamber

Search Result 120, Processing Time 0.022 seconds

Study of plasma induced charging damage and febrication of$0.18\mu\textrm{m}$dual polysilicon gate using dry etch (건식각을 이용한 $0.18\mu\textrm{m}$ dual polysilicon gate 형성 및 plasma damage 특성 평가)

  • 채수두;유경진;김동석;한석빈;하재희;박진원
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4A
    • /
    • pp.490-495
    • /
    • 1999
  • In 0.18 $\mu \textrm m$ LOGIC device, the etch rate of NMOS polysilicons is different from that of PMOS polysilicons due to the state of polysilicon to manufacture gate line. To control the etch profile, we tested the ratio of $Cl_2$/HBr gas and the total chamber pressure, and also we reduced Back He pressure to get the vertical profile. In the case of manufacturing the gate photoresist line, we used Bottom Anti-Reflective Coating (BARC) to protect refrection of light. As a result we found that $CF_4O_2$ gas is good to etch BARC, because of high selectivity and good photoresist line profile after etching BARC. in the results of the characterization of plasma damage to the antenna effect of gate oxide, NO type thin film(growing gate oxide in 0, ambient followed by an NO anneal) is better than wet type thin film(growing gate oxide in $0_2+H_2$ ambient).

  • PDF

Fabrication and Operation Testing of an Air-cored Pulse Transformer for Charging a High Voltage Pulse Forming Line (고압 펄스 성형라인 충전을 위한 공심형 고압 펄스트랜스의 제작과 동작 특성)

  • Jin, Yun-Sik;Kim, Young-Bae;Kim, Jong-Soo;Ryoo, Hong-Je;Cho, Chu-Hyun;Rim, Geun-Hee;Lim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.939-944
    • /
    • 2010
  • A high voltage air-cored helical strip/wire type pulse transformer has been fabricated for charging of a high voltage pulse forming line. As a primary coil, copper strip of 25mm width was wound helically around a MC nylon cylinder. For a secondary coil, copper enameled wire of 1mm diameter was wound around conical cylinder in order to provide insulation between two windings. The coupling coefficient of 0.53 was obtained when two coils were combined coaxially in the insulation oil filled chamber. Voltage gain and energy transfer efficiency were investigated by varying the parameters of primary and secondary circuit. Test results shows that the voltage gain increases up to 17 with increasing the primary capacitance up to 200nF. And highest energy transfer efficiency of 44% was obtained when the dual resonant operation condition was nearly satisfied. The pulse transformer developed in this study can be used for charging the middle conductor of a Blumlein pulse forming line.

Design and Fabrication of a Dual Cylindrical Microwave and Ohmic Combination Heater for Processing of Particulate Foods

  • Lee, Seung Hyun;Choi, Won;Park, Sung Hee;Jun, Soojin
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.250-260
    • /
    • 2015
  • Purpose: Dual cylindrical microwave chambers equipped with an ohmic heating tube were designed and fabricated to maximize the electric field strength for expeditious heat treatment of particulate foods. Methods: The efficacy of the combination heater was investigated by simulating the electric field distribution by using COMSOL Multiphysics software. Results: All components of the designed microwave heating unit were suitable for transmitting maximal microwave power to the load. The simulated electric field distribution implied that single-mode microwave heating would be sufficient for the steady generation of a highly localized heating zone in the cavity. During impedance matching, the calculated reflection coefficient ($S_{11}$) was small, possibly implying minimal power loss and wave reflection in the designed microwave heating chamber. Conclusions: This study demonstrates the possibility of concentrating the microwave power at the centerline for a single-frequency microwave, for thermal treatment of multiphase foods without attenuating the microwave power.

A Study of Combustion Instability Mode in Dual Swirl Gas Turbine Combustor by PLIF and Chemiluminescence Measurement (PLIF 및 자발광 계측을 이용한 이중선회 가스터빈 연소기에서 연소불안정 모드 연구)

  • Choi, Inchan;Lee, Keeman;Juddoo, Mrinal;Masri, A.R.
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • This paper described an experimental investigations of combustion instability mode in a lean premixed dual swirl combustor for micro-gasturbine system. When such the instability occurs, a strong coupling between pressure oscillations and unsteady heat release excites a self-sustained acoustic wave which results in a loud, annoyed sound and may also lead a structural damage to the combustion chamber. The detailed period of flame behavior and heat release in combustion instability mode have been examined with high speed OH and CH-PLIF system and $CH^*$ chemiluminescence measurement, flame tomography with operated at 10 kHz and 6 kHz each. Experiment results suggest that unstable flame behavior has a specific frequency with 200 Hz and this frequency is accords with about 1/2 sub-harmonic of combustor resonance frequency, not fundamental frequency. This is very interesting phenomenon that have not reported yet from other previous works. Therefore, when a thermo-acoustic instability with Rayleigh criterion occurs, the fact that the period of heat release and flame behavior are different each other was proposed for the first time through this work.

Analysis of in-cylinder steady flow for dual-intake-valve gasoline engine using single-frame particle tracking velocimetry (단일 프레임 입자 추적법을 이용한 흡입 2밸브 가솔린 기관의 실린더 내 정상 유동 해석)

  • Lee, Chang-Sik;Lee, Gi-Hyeong;Im, Gyeong-Su;Jeon, Mun-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.650-658
    • /
    • 1997
  • Analysis and control of intake charge motion such as swirl and tumble are very important factors in improving the gasoline engine performance. In this paper, single-frame PTV (particle tracking velocimetry) is used to investigate intake tumble patterns in a steady flow test rig of gasoline engine with dual-intake-valve and pent-roof combustion chamber. Intake tumble pattern is quantified in accordance with blockage ratio of TIV (tumble intensifying valve) with single- frame PTv.The view of the instantaneous 2-D velocity field gives a realistic understanding of in-cylinder flow field. Thus it is confirmed that PTV is a effective tool in engine design. In conventional port, two tumble structures appear clearly, and the larger one is observed under the exhaust valve side and the smaller is right below the intake valve side. The larger vorticity is observed in TIV port, thus it is concluded that TIV have an effect on intensified tumble motion in cylinder flow.

The Ablation Effect of Fabric/EPDM Rubber with Manufacturing process (Fabric/EPDM계 고무의 제작 공정에 따른 삭마 특성)

  • Kim, Jin-Yong;Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man;Rhee, Young-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.92-95
    • /
    • 2012
  • The dual pulse rocket motor is a pressure vessel containing two pulse grains separated by a pulse separation device such as a fragile bulkhead. One of the important things in this systems is case insulation design using the excellent materials in the 1st stage pulse motor. We investigated manufacturing process of fabric/EPDM chamber insulations in order to protect the 1st stage pulse motor case with high intensity gas flow. Simulation motor connected with extension tube having FRP disc was designed to study ablation characteristics of insulation.

  • PDF

Development of Fuzzy Logic-Based Diagnosis Algorithm for Fault Detection Of Dual-Type Temperature Sensor for Gas Turbine System (가스터빈용 듀얼타입 온도센서의 고장검출을 위한 퍼지로직 기반의 진단 알고리즘 개발)

  • Young-Bok Han;Sung-Ho Kim;Byon-Gon Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.53-62
    • /
    • 2023
  • Due to the recent increase in new and renewable energy, gas turbine generators start and stop every day to supply high-quality power, and accordingly, the life span of high-temperature parts is shortened and the failure of combustion chamber temperature sensors increases. Therefore, in this study, we proposed a fuzzy logic-based failure diagnosis algorithm that can accurately diagnose and systematically detect the failure of the sensor when the dual temperature sensor used for gas turbine control fails, and to confirm the usefulness of the proposed algorithm We tried to confirm the usefulness of the proposed algorithm by performing various simulations under the matlab/simulink environment.

Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite (이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구)

  • Lee, Jun-Bong;Park, Jong-Duk;Kwon, Su-Mi;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

Dual-band Planar Monopole Antenna for Autonomous Vehicle (자율주행자동차를 위한 이중대역 평판 모노폴 안테나)

  • Yoon, Yonghyun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.4
    • /
    • pp.343-348
    • /
    • 2019
  • In this paper, a dual-band antenna is proposed for the autonomous vehicle as well as omni-directional. The proposed antenna operates in the 4G/LTE band (1,710~2,170MHz) and 5G/NR band (3,400~3,700MHz). In order to obtain the dual-band operation, the planar monopole antenna is proposed as the novel structure with single port of the 50ohm. To give the properties of dual-band, an additional antenna element with slit was added to the planar monopole antenna, and then a structural adjustment parameter was optimized for achieving the target performance in bands. The planar monopole antenna in the LTE band acts as the coupled feed for the added parasitic radiator in the 5G NR band. The proposed antenna has $38.5{\times}36.0{\times}1.0[mm^3]$ on a ground with diameter of 96mm. From the fabrication and measurement results, the impedance bandwidth (VSWR<2) of the proposed antenna covers 1,480~2,260MHz (LTE band: 1,710~2,170MHz) and 3,310~3,930MHz (5G NR band: 3,400~3,700MHz). The proposed planar monopole antenna also obtained the measured gain and radiation pattern of omni-directional radiation pattern in the anechoic chamber.

LEAKAGE EVALUATION OF SEVERAL SEALERS USING ANAEROBIC BACTERIAL LEAKAGE MODEL (혐기성세균모델을 이용한 봉함제(Sealer)의 미세누출에 관한 연구)

  • Bae, Yong-Kue;Oh, Tae-Suk;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.235-242
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the sealing ability of three sealers(Sealapex, Pulp canal sealer, AH26) used with continuous wave method using an anaerobic bacterial leakage model. 53 extracted human teeth with straight and single canals were prepared with crown-down pressureless technique using .04, .06 taper Profile(Maillefer, Swiss). Master apical file was maintained as #35 K-file. All canals of the experimental teeth were obturated with continuous wave method using System B(Analytic technology, U.S.A.) The teeth were randomly divided into three experimental groups of 15 and two control groups of 4. Experimental group 1 was obturated with Sealapex and group 2 with Pulp canal sealer, and group 3 with AH26. A dual chamber anaerobic bacterial leakage model was assembled. Brain heart infusion with yeast extract, hemin, menadion, and the chromogenic indicator bromocresol purple was used as the culture broth for Fusobacterium nucleatum(VPI 10197), The specimens were incubated in anaerobic chamber at $37^{\circ}C$ and were observed every 2 to 3 clays, The coronal leakage was evaluated through the color change of culture broth in lower chamber for 60 days. The results were as follows: 1. The incidence of bacterial leakage in group 1 (Sealapex group was 80%, 53% in group 2 (Pulp canal sealer), 27% in group 3 (AH26). 2. There were statistically significant differences in leakage scores between group 1 and group 2, and between group 1 and group 3, respectively. (P<0.05) 3. There was no significantly difference in leakage score between group 2 and group 3. (P>0 05)

  • PDF