• 제목/요약/키워드: Dual Camera

검색결과 126건 처리시간 0.03초

WLAN에서 스트리밍 서비스이 QoS를 제공하기 위한 GOP 패턴 및 프레임 중요도에 따른 버퍼 관리 기술 (A Buffer Management Algorithm based on the GOP Pattern and the Importance of each Frame to Provide QoS for Streaming Services in WLAN)

  • 김재현;이현진;이규환;노병희
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.372-375
    • /
    • 2008
  • IEEE 802.11e standardized the EDCA mechanism to support the priority based QoS. And the virtual collision handler schedules the transmission time of each MAC frame using the internal back-off window according to the access category(AC). This can provides the differentiated QoS to real-time services at the medium traffic load condition. However, the transmission delay of MAC frame for real-time services may be increased as the traffic load of best effort service increases. It becomes more critical when the real-time service uses a compressed mode video codec such as moving picture experts group(MPEG) 4 codec. That is because each frame has the different importance. That is, the I-frame has more information as compared with the P- and the B-frame. In this paper, we proposed a buffer management algorithm based on the frame importance and the delay bound. The proposed algorithm is consisted of the traffic regulator based on the dual token bucket algorithm and the active queue management algorithm. The traffic regulator reduces the transmission rate of lower AC until that the virtual collision handler can transmit an I-frame. And the active queue management discards frame based on the importance of each frame and the delay bound of head of line(HoL) frame when the channel resource is insufficient.

  • PDF

Characterization of stacked geotextile tube structure using digital image correlation

  • Dong-Ju Kim;Dong Geon Son;Jong-Sub Lee;Thomas H.-K. Kang;Tae Sup Yun;Yong-Hoon Byun
    • Computers and Concrete
    • /
    • 제31권5호
    • /
    • pp.385-394
    • /
    • 2023
  • Displacement is an important element for evaluating the stability and failure mechanism of hydraulic structures. Digital image correlation (DIC) is a useful technique to measure a three-dimensional displacement field using two cameras without any contact with test material. The objective of this study is to evaluate the behavior of stacked geotextile tubes using the DIC technique. Geotextile tubes are stacked to build a small-scale temporary dam model to exclude water from a specific area. The horizontal and vertical displacements of four stacked geotextile tubes are monitored using a dual camera system according to the upstream water level. The geotextile tubes are prepared with two different fill materials. For each dam model, the interface layers between upper and lower geotextile tubes are either unreinforced or reinforced with a cementitious binder. The displacement of stacked geotextile tubes is measured to analyze the behavior of geotextile tubes. Experimental results show that as upstream water level increases, horizontal and vertical displacements at each layer of geotextile tubes initially increase with water level, and then remain almost constant until the subsequent water level. The displacement of stacked geotextile tubes depends on the type of fill material and interfacial reinforcement with a cementitious binder. Thus, the proposed DIC technique can be effectively used to evaluate the behavior of a hydraulic structure, which consists of geotextile tubes.

Ho-166-CHICO 치료 후 평면 영상을 이용한 방사선 흡수선량의 계산 (Radiation Absorbed Dose Calculation Using Planar Images after Ho-166-CHICO Therapy)

  • 조철우;박찬희;원재환;왕희정;김영미;박경배;이병기
    • 한국의학물리학회지:의학물리
    • /
    • 제9권3호
    • /
    • pp.155-162
    • /
    • 1998
  • 방사성 동위원소의 치료에 베타 방출 선원이 많이 이용되고 있다. 베타 방출 핵종 들은 투과력이 약해 방사선 도달거리 (range)가 짧아 병소내에 직접 주입하여 선택적으로 병소만을 조사하여 치료 의 효과를 얻을 수 있고 주변 정상 조직의 방사선 피폭을 줄일 수 있다. 최근 한국 원자력연구소의 원자로인 하나로를 이용하여 베타 입자 방출체인 Ho-l66 용액을 만들어 여기에 키토산 화합물을 표지 하였다. Ho-l66 은 고 에너지 베타 방출체라는 점과 일부 감마선이 방출됨으로써 감마카메라로 쉽게 영상을 얻을 수 있다는 장점이 있다. 본 연구에서는 감마카메라로 얻은 평면 영상을 이용하여 Ho-l66으로 치료한 부위와 그 주변의 정상 장기들의 방사선 홉수선량을 구하였다. 감마카메라는 Siemens 의 2중 head를 가진 Multispect2 시스템이 이용되었고, 콜리메이터는 medium energy, 최대 에너지는 80 keV, 창은 20%로 5분간 영상을 획득하였다. Ho-166 에 대한 투과인자 (transmission factor)는 환자 있을 때와 없을 때의 영상으로 관심영역의 ROIs 의 비로 구하였다 .3일간의 평면 영상으로 유효반감기를 구하여 Marinelli 공식과 MIRD 공식으로 베타입자에 대한 방사선 흡수선량을 구하였다. 감마선에 의한 흡수선량은 매우 적으므로 무시하였다. Transmission factor는 환자에 따라 다르지만 1110 MBq(30 mCi)을 주입하여 치료에 임한 간암 환자의 경우 간은 4.6, 비장은 4.65, 폐는 3.34, 뼈는 5.65 의 값을 보였다. 방사선 홉수선량은 tumor 에는 179.7, 정상간에는 16.3, 비장은 18.5, 폐에는 7.0, 뼈에는 9.0 Gy 가 각각 계산되었다. 이를 tumor dose 에 100%로 normalization 시킬 경우 정상간, 비장, 폐, 뼈에 각각 9.1, 10.3, 3.9, 5.0%로 분포되었음을 알았다. 본 연구를 통하여 tumor dose 뿐만이 아니고 주변 주요 위험장기 (critical organ) 에 대한 방사선 흡수선량을 전ㆍ후면 평면영상으로 얻을 수 있음을 보여 줌으로써 평면영상법을 이용한 dosimetry 의 가능성을 보았다. 또한 주변 주요 위험 장기의 한계선량에 맞는 주입할 양을 결정하는데 기초 자료가 될 수 있음을 보여준다.

  • PDF

골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구 (Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy)

  • 김우철;박원;김현정;박성용;조영갑;노준규;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제16권4호
    • /
    • pp.497-504
    • /
    • 1998
  • 목적 : matrix ion chamber type의 EPID와 video camera based EPID를 이용한 portal image와 기존의 film을 이용한 port film의 영상의 질을 객관적으로 비교 평가하여 EPID의 유용성을 알아보고자 본 연구를 계획하였다. 대상 및 방법 : 1997년 4월부터 10월까지의 인하대 병원과 세브란스 병원에서 방사선 치료를 받은 골반강내 치료 환자 각 10명씩을 대상으로 환자 1명 당 5-10회의 port film과 EPID를 이용한 portal image를 동시에 얻어 비교하였다. 환자의 나이는 32세에서 79세이었고 2명의 AP영상을 제외하고는 모두 PA영상을 얻었다. 환자의 두께는 17cm에서 20cm으로 비교적 균일하였다. beam energy는 10MV X-ray를 사용하였고 dose rate은 100-300MU/min으로 2-10MU을 주어 영상을 얻었다. port film은 Kodak diagnostic film을 사용하였고 film을 넣는 cassette는 납을 전후에 부착한 것을 이용하였다. source to detector(film) distance는 140cm으로 하였다. 영상의 판독은 4명의 치료방사선과 의사에 의해서 시행되었으며 pelvic brim, sacrum, acetabulum, iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint를 각각 very clear(1), clear(2), visible(3), not clear(4), not visible(5) 다섯 단계로 나누어 점수를 주었다. 결과 : video camera based EPID를 이용하여 얻은 영상을 비교하여 보았을 때 film을 이용한 port film과 enhancement를 시행하지 않은 portal image는 각 해부학적 구조에서는 차이를 보이지 않았다. 그러나 portal image를 window level로 영상의 변화를 주었을 때는 sacrum과 obturator는 영상의 판독에 도움이 되었다. 또한 portal image를 CLAHE로 enhance를 하였을 때는 모든 해부학적 구조물의 판독이 film보다 용이한 것으로 나타났다. matrix ion chamber type의 EPID를 이용하여 얻은 영상에서도 역시 port film과 영상의 변화를 주지 않은 portal image간에는 커다란 차이를 보이지 않았으나, portal image를 window level로 변화를 주었을 경우는 portal film에 비하여 영상의 질이 더욱 좋아지을 알 수 있었다. 결론 : 방사선 치료를 받는 환자 중에서 골반강의 영상에서는 EPID의 영상의 질은 기존의 port film과 비교하여 차이가 없었으며, window level로 영상에 변화를 주거나 enhance를 하였을 경우는 port film보다 더 나은 영상을 얻을 수 있어 기존의 port film을 대체 할 수 있을 것으로 생각된다.

  • PDF

적외선 우주배경복사 관측 실험 2(CIBER2) 국제 공동 연구 (KOREAN PARTICIPATION ON THE COSMIC INFRARED BACKGROUND EXPERIMENT 2 (CIBER2))

  • 이대희;박원기;문봉곤;박성준;김민규;김건희;남욱원;표정현;정웅섭;박영식;김일중;한원용
    • 천문학논총
    • /
    • 제30권1호
    • /
    • pp.11-16
    • /
    • 2015
  • First light galaxies have predictable linear clustering, and are expected to produce fluctuations with a characteristic spatial power spectrum, which peaks at an angular scale of ~ 10 arcminutes and in the $1-2{\mu}m$ spectral regions. The Cosmic Infrared Background ExpeRiment 2 (CIBER2) is a dedicated sounding rocket mission for measuring the fluctuations in the extragalactic infrared background light, following up the previous successful measurements of CIBER1. With a 28.5 cm telescope accompanied with three arms of camera barrels and a dual broadband filter on each H2RG (${\lambda}_c=2.5{\mu}m$) array, CIBER2 can measure 6 bands of wide field ($1.1{\times}2.2$ degrees) up to 3 AB magnitudes deeper than CIBER1. This project is leaded by California Institute of Technology/Jet Propulsion Laboratory, collaborating internationally with Institute of Space and Astronautical Science in Japan, Korea Astronomy and Space Science Institute, Korea Basic Science Institute, and Seoul National University. The Korean team is in charge of 1) one H2RG scientific array, 2) ground station hardware and software, 3) telescope lenses, and 4) flight and test bed electronics fabrication. In this paper, we describe the detailed activities of the Korean participation as well as the current status of the CIBER2 project.

두경부 종양에서 $^{99m}Tc$-(V)-DMSA 영상술의 진단적 유용성 (The Clinical Role of $^{99m}Tc$-(V)-DMSA Imaging in Patients with Head and Neck Cancer)

  • 배선근;이재태;박준식;박인규;현동우;이영학;김정균;안병철;최지용;손상균;이규보
    • 대한핵의학회지
    • /
    • 제29권4호
    • /
    • pp.526-532
    • /
    • 1995
  • 두경부의 악성 종양의 진단에서 $^{99m}Tc$-(V)-DMSA 영상술은 비교적 높은 양성율을 보여 주었고 (Planar 65%, SPECT 90%), 원격 전이부위의 영상진단에도 도움이 되었다. 그러나 $^{99m}Tc$-(V)-DMSA는 두경부의 양성 병변에도 섭취가 될 수 있어, 판독 시 임상검사 및 다른 영상소견과의 비교검토가 필요할 것으로 판단된다.

  • PDF

Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교 (The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT)

  • 김성환;남기표;류재광;윤순상
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.3-7
    • /
    • 2012
  • 심근관류 SPECT의 영상획득 방법에는 Body contour와 Circular 방식이 있고, 환자와 검출기 사이의 거리를 줄이기 위해 Body contour 방식을 주로 사용한다. 그러나 이중(Dual) 검출기 장비에서 수직방식으로 검출기를 설정하여 영상을 획득하는 경우에는 환자와 검출기 사이의 거리가 Body contour 방식이 Circular 방식에 비해 더 증가하는 경향이 있다. 본 연구의 목적은 이중 검출기 장비에서 수직방식으로 검출기를 설정하여 영상을 획득하는 경우, Body contour 방식과 Circular 방식에서 환자와 검출기 사이의 거리를 비교하고, 거리에 따라 영상에 미치는 영향을 파악하여 영상의 질을 높이기 위한 방안을 제시하고자 시행하였다. 실험에 사용된 장비는 GE INFINIA Gamma Camera와 Anthropomorphic torso 모형에 심장 모형을 삽입하여 영상을 획득하였고, 2011년 8월 본원에서 심근관류 SPECT를 시행한 환자 40명을 대상으로 하였다. 모형 제작은 실제 환자조건과 동일하게 하기 위하여 심근에 74 kBq (0.22 mCi)/cc, 폐에 2.59 kBq ($60{\mu}Ci$)/cc, 연부조직에 11.1 kBq (2.2 mCi)/cc의 201-Tl을 주입하여 제작하였고, 영상획득 조건은 회전각 $6^{\circ}$, 50 sec/frame으로 환자와 동일한 조건으로 하였다. 영상획득 방식에 따른 차이를 확인하기 위해 Body contour와 Circular 방식으로 영상을 획득하여 환자와 검출기 사이의 거리를 각각 측정하여 비교하였고, 정상군과 비 정상군의 영상을 육안 분석하였다. 거리에 따라 영상에 미치는 영향을 확인하기 위해, 모형 실험에서 Circular 방식으로 회전반경을 18.8, 21.8, 23.8, 25.8, 28.8 cm 로 다르게 설정하여 영상을 획득하였고, 각 영상에서 심첨(Apex)에 관심영역을 설정하여 반치폭을 비교하였다. 모형 실험 결과, Body contour를 이용한 실험에서 산출된 반치폭은 6.23 mm이고, Circular mode에서 18.8, 21.8, 23.8, 25.8, 28.8 cm의 회전반경으로 산출된 반치폭은 각각 5.41, 6.24, 6.33, 6.42, 6.93 mm이다. 환자 데이터에서 Body contour의 회전반경이 -3.5 cm ~ 9.5 cm으로 차이를 보였고, Circular mode에 비해 평균 2.5 cm 더 큰 차이를 보였다. 본 연구를 통해, INFINIA 장비에서 Circular mode가 Body contour를 사용한 영상 획득 방법보다 낮은 반치폭을 보였다. 비록 INFINIA장비의 두 가지 영상 획득 방식에 대한 비교였지만, INFINIA장비를 이용한 심근관류 검사에서는 Circular mode 의 영상 획득 방식이 더 적합하다고 사료된다.

  • PDF

게이트 심근 관류 스펙트의 심기능 지표의 정상 참고값 : $QGS^{\circledR}$ 프로그램과 $4DM^{\circledR}$ 프로그램의 비교 (Reference Values of Functional Parameters in Gated Myocardial Perfusion SPECT : Comparison with $QGS^{\circledR}$ and $4DM^{\circledR}$ Program)

  • 정영진;박태호;차광수;김무현;김영대;강도영
    • 대한핵의학회지
    • /
    • 제39권6호
    • /
    • pp.430-437
    • /
    • 2005
  • 목적: 게이트 심근 관류 스펙트 결과의 정량적 평가를 위해 여러 프로그램들이 사용되고 있다. 하지만 프로그램별로 각각의 정상 범위의 설정 없이 외국의 자료만을 토대로 프로그램의 구분 없이 일률적으로 판독에 적용하고 있다. 이에 심혈관 질환의 가능성이 낮은 환자를 대상으로 본원에서 일반적으로 사용하고 있는 QGS와 4DM의 심기능 지표(EDV, ESV, EF)에 대한 정상 값을 구하였고, 두 프로그램간의 결과 치에 대한 상관관계도 조사하였다. 대상 및 방법: Pryor 등에 의해 만들어진 평가표에 근거하여 심혈관 질환의 가능성이 10% 미만인 남녀 77명을 대상으로 아데노신 부하법을 이용한 Tc-99m MIBI 게이트 심근 관류 스펙트를 실시하였다. EDV, ESV, EF의 결과 분석은 QGS와 4DM을 이용하였으며, 좌심실의 경계는 자동으로 설정하도록 하였다. 결과: QGS에서 부하기 좌심실의 평균 EDV, ESV, EF는 각각 $78.2{\pm}25.2ml,\;27.4{\pm}12.9ml,\;66.6{\pm}8.0%$ 이었고 휴식기의 결과치와 통계학적으로 큰 차이는 없었다(p>0.05). 4DM에서 부하기 좌심실의 평균 EDV, ESV, EF는 각각 $89.1{\pm}26.4ml,\;29.1{\pm}12.8ml,\;68.5{\pm}6.7%$ 이었다. 대체적으로 QGS와 마찬가지로 휴식기의 결과치와 큰 차이는 없었으나 EF의 경우에서 부하기와 휴식기에 통계학적인 차이가 있었고 (p<0.05) 휴식기의 EF가 약간 큰 값을 보였다(부하기 $68.5{\pm}6.7%$ vs 휴식기 $70.9{\pm}8.0%$). 두 프로그램에서 EDV, ESV, EF의 결과 값의 상관관계는 부하기에서 각각 0.95, 0.93, 0.71이었고 휴식기에서 각각 0.95, 0.90, 0.69으로 대체적으로 좋았으나 Bland-Altman분석에서 두 프로그램의 일치의 한계 값의 범위가 비교적 컸음을 볼 수 있었다. 결론: 이번 연구를 통하여 심혈관 질환의 가능성이 낮은 환자에서 QGS와 4DM 프로그램 각각의 EDV, ESV, EF의 정상 값을 구하였다. 두 프로그램의 상관관계는 높지만 두 프로그램의 결과 값을 혼용하여 사용할 수는 없을 것이다. 이를 이용하여 앞으로 판독에 유의한 참고 자료로써 사용될 수 있을 것으로 생각된다.

Hydroxyapatite 안구보충물삽입술 후 골신티그라피를 이용한 섬유혈관증식 평가: 평면영상과 SPECT 영상에서의 비교 (Assessment of Vascularization within Hydroxyapatite Ocular Implant by Bone Scintigraphy: Comparative Analysis of Planar and SPECT Imaging)

  • 임석태;손명희;박순아
    • 대한핵의학회지
    • /
    • 제33권6호
    • /
    • pp.475-483
    • /
    • 1999
  • 목적: 안구보충물로 사용된 hydroxyapatite 내로의 섬유혈관증식은 이물질 반응으로 인한 염증의 동반없이 의안의 운동성을 유지시키기 위한 운동성 나사못을 삽입하는데 중요한 역할을 한다. 안구보충물 삽입술 후에 섬유혈관증식의 정도를 알아보는데 Tc-99m MDP를 이용한 평면영상과 단면영상에서 정성적 평가와 정량적 평가의 비교분석을 함으로서 완전한 섬유혈관증식을 예측하는데 단면영상의 유용성을 알아보고자 하였다. 대상 및 방법: 안구 제거술후 hydroxyapatite를 이용하여 안구보충술을 시행받고 $197{\pm}81$일 후에 골신티그라피를 시행받은 17명의 환자(남:녀=12:5, 연령; $50.4{\pm}17.5$세)의 18예를 대상으로 하였다. 골신티그라피는 Tc-99m MDP 740 MBq를 정맥주사 후 4시간 경과뒤에 이중헤드 감마카메라(ECAM, Siemens, Germany)로 안면부 평면영상을 얻은 후 이어서 단면영상을 얻었다. 평면영상과 단면영상에서의 안구보충물의 방사능 섭취가 비교(nasal bridge)보다 약한 경우를 grade 1, 비슷한 경우를 grade 2, 강한 경우를 grade 3로 평가하였고, 정상안구에 대한 안구보충물의 섭취비를 정량적으로 구하여 운동성 나사못 삽입술 후 시행된 세극등 검사에서 염증반응의 동반 없이 완전한 섬유혈관증식을 보인 환자 군과 염증 반응의 동반과 함께 불완전한 섬유혈관증식을 보인 환자 군으로 나누어 비교 분석하였다. 결과: 평면영상에서 grade 1은 9예, grade 2가 1예, grade 3가 2예로 충분한 섬유혈관증식을 의미하는 grade 2와 3를 보인 경우가 9예 (50%) 이었으나 단면영상에서는 grade 1이 6예, grade 2가 4예, grade 3가 8예로 평면영상에 비하여 grade 2와 3를 보이는 경우가 12예(61%) 이었다. 정성적 평가에 의한 완전한 섬유혈관증식을 예측하는 데 있어서 평면영상은 예민도가 60% (9/15),특이도 100% (3/3), 양성예측률 100% (9/9), 음성예측률 33.3% (3/9), 정확도 66.7% (12/18) 이었고 단면영상은 예민도 80% (12/15), 특이도 100% (3/3), 양성예측률 100% (12/12), 음성예측률 50% (3/6), 정확도 83.3% (15/18) 이었다. 정량적으로 구한 안구보충물 내의 방사능 섭취비는 평면영상에서 grade 1은 $1.19{\pm}0.10$, grade 2는 $2.16{\pm}0.43$, grade 3는 $3.57{\pm}0.74$로 grade가 높을수록 정량적 섭취비가 유의하게 증가하였다(p<0.001). 단면영상에서 grade 1은 $3.06{\pm}1.22$, grade 2는 $3.71{\pm}0.83$, grade 3는 $12.49{\pm}4.31$로 grade가 높을수록 정량적 섭취비가 유의하게 증가하였다(p<0.001). 완전한 섬유혈관증식을 보인 환자 군과 불완전한 섬유혈관증식을 보인 환자군으로 나누어 정량적으로 측정한 방사능 섭취비를 비교시 평면영상에서는 $1.96{\pm}0.87$$1.17{\pm}0.08$로 유의한 차이를 보이지 않았으나 단면영상에서는 $8.44{\pm}5.45$$2.20{\pm}0.87$로 유의한 차이를 보였다 (p<0.05). 결론: 안구보충물 삽입 후 섬유혈관증식을 평가할 때 평면영상에 비하여 단면영상이 섬유혈관증식 정도를 평가하는데 보다 도움을 주었다.

  • PDF

게이트 심근관류 SPECT상 운동 유발성 기절심근을 보이는 환자의 운동부하 심전도, 관류 SPECT 및 심혈관 조영술 소견 (Characteristic Findings of Exercise ECG Test, Perfusion SPECT and Coronary Angiography in Patients with Exercise Induced Myocardial Stunning)

  • 안병철;서지형;배진호;정신영;박헌식;이재태;채성철;이규보
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.225-232
    • /
    • 2004
  • 목적 : 관상동맥질환을 가진 환자에서는 운동부하 후 일시적인 심근기절로 인하여 좌심실의 벽운동이상과 좌심실구혈률 감소가 발생될 수 있다. 본 연구는 운동 후 좌심실기능저하를 보이는 환자와 그렇지 않은 환자의 관상동맥조영술과 운동부하 심근관류 SPECT소견을 비교분석 하고자 하였다. 대상 및 방법 : 운동부하심전도, 관상동맥조영술 및 심근관류 SPECT를 시행한 환자 중 게이트 SPECT로 구한 좌심실구혈률이 운동 후 5%이상 감소된 36명 (기절심근군)과 운동부하 후 좌심실구혈률 변화가 1%이하인 16명 (비기절심근군)을 대상으로 하였다. 답차를 이용한 운동부하중 심전도검사를 시행하고, 최대 운동부하시 Tc-99m MIBI 740MBq을 투여한 후 이중헤드 감마카메라(Vertex Plus, ADAC)로 부하 심근관류영상을 얻었다. 심혈관조영술은 위 검사로 부터 1개월내에 시행되었다. 결과 : 기절심근군은 비기절심근군에 비해 고콜레스테롤혈증의 빈도가 유의하게 높았으며(45.5 대 7.1%, p=0.01), 당뇨병의 빈도가 높은 경향을 가졌으며, 고혈압의 빈도는 낮은 경향을 가졌으나 통계적으로 유의하지 않았다. 비기절심근군에 비해 기절심근군에서 SPECT 검사상 관류결손의 범위 (18.2% 대 9.1%, p=0.029)와 정도 (13.5 대 6.9, p=0.04)는 더 컸으며, 가역성정도 (7.9 대 4.8, p=0.09)는 더 큰 경향을 가졌으며, 운동부하심전도상 허혈양성 소견의 빈도가 높은 경향을 가졌다(82.9% 대 64.3%, p=0.095). 심혈관조영술상 중증 ($80{\sim}99%$)의 관상동맥협착의 빈도가 높은 경향을 보였으나 (64.7% 대 35.7%, p=0.064), 다혈관질환의 빈도 (62.5% 대 46.2%, p=0.279), 협착정도 (75.8% 대 66.8%, p=0.468)에는 유의한 차이가 없었다. 기절심근군 중 관류결손이 발견되지 않았던 4명 (11.1%) 모두에서 유의한 관상동맥협착이 있었고 혈관재개통술이 시행되었다. 결론 : 운동부하로 5%이상의 좌심실구혈률의 감소를 보이는 환자는 그렇지 않은 환자에 비하여 심근관류 SPECT상 관류결손 크기와 정도가 크며, 가역성이 더 높은 경향을 나타내었으며, 혈관조영술상 관상동맥협착 정도가 중증인 경향을 가지고 있으며, 비록 관류 SPECT상 결손이 없더라도 관상동맥조영술상 혈관 재개통술이 필요할 정도의 유의한 협착이 있어, 이러한 환자에서는 적극적인 진단과 치료적 개입이 필요할 것으로 생각된다.