Study on Movement of Wood (목재(木材)의 치수변동(変動)에 관(關)한 연구(硏究))

  • Jung, Hee-Suk;Lee, Phil-Woo;Lee, Nam-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.36-42
    • /
    • 1986
  • Both the control and heated specimen of oak, hornbean, alder, poplar, red pine and pitch pine among domestic commercial species and taun imported were used for radial and tangential shrinkage and movement that occurred on changing the relative humidity of the atmosphere from 90 percent to 60 percent at $25^{\circ}C$. The results of this study were as follows. 1. The radial and tangential shrinkage of the control and heated hornbean and oak wood, except alder, of high specific gravity showed greater than species with low specific gravity. The ratio of tangential to radial shrinkage was 1.46 for taun to 2.70 for alder. Green volume specific gravity of the heated and soaked specimen of all species except poplar decreased 1.5 to 3.1 percent. Shrinkage of the heated specimen increased more than that of the control specimen, and antishrink efficiency of all timbers except alder had negative value. Shrinkage from green to air dry of treated specimens increased more than case of total shrinkage, and radial shrinkage of those specimen increased greater than tangential shrinkage. 3. The movement of the heating specimen for 120 hours decreased than those of the control and the heating specimen for 240 hours. The movement of heating oak, poplar, red pine and pitch pine (or 240 hours increased rather than those of the control specimen.

  • PDF

Basic research on the Building Energy Load Depending on The Climate Change in Korea (대한민국 표준기상데이터의 변화추이와 건물부하량에 관한 기초연구)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Kang, Hyun-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.66-72
    • /
    • 2009
  • As 'Low Carbon Green Building' is highly required, programs to evaluate building performance are actively and commonly used. For most of these programs, dynamic responses of buildings against external weather changes are very important. In order to simulate the programs, weather data of each region must be properly entered to estimate accurate amount of building energy consumption. To this end, the existing weather data and weather data of KSES were compared and analyzed to find out how weather changes. Energy load of Korea's standard houses was also analyzed based on this data. As a result, data corresponding to June ${\sim}$ September when cooling is supplied shows 23% of average increase with 30% of peak increase(June). On the other hand, data corresponding to November ${\sim}$ February when heating is supplied shows 29% of average decrease with 34% of peak decrease(November). Increase in cooling load and decrease in heating load in the above data comparison/analysis show that KSES 2009 data reflects increase in average temperature caused by global warming unlike the existing data. Increase in dry-bulb temperature depending on weather change of standard houses increases cooling load by 17% and decreases heating load by 36%

Performance Improvement Technology on a Continuous Heating Heat Pump at Frost Condition (착상조건에서 연속난방이 가능한 히트펌프 성능 향상 기술)

  • Jeon, Chang-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.573-577
    • /
    • 2013
  • Heat pumps come into wide use because high energy efficiency can be obtained and diverse heat sources like geothermal heat, waste heat and air are available. It is necessary for an air source heat pump to defrost in order to remove frost on the surfaces of an outdoor heat exchanger. It is impossible for continuous heating if reverse cycle operation is used as defrosting method, furthermore it causes the degradation of COP. In this study an fin-tube heat exchanger with three rows was used as an outdoor coil. One row among three rows of the heat exchanger was used like a condenser in order to remove frost on it, the others were used as evaporator to accomplish continuous heating. Each row was switched in order from a condenser to an evaporator in specified time interval. Tests were carried out during minimum 180 minutes at the defrost-heating test condition(dry bulb temperature $2^{\circ}C$, wet bulb temperature $1^{\circ}C$) described in KS C 9306. Time-averaged COP was about 20% higher than that of conventional defrosting method.

Experimental study on the influence of heating surface inclination angle on heat transfer and CHF performance for pool boiling

  • Wang, Chenglong;Li, Panxiao;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.;Deng, Jian
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.61-71
    • /
    • 2022
  • Pool boiling heat transfer is widely applied in nuclear engineering fields. The influence of heating surface orientation on the pool boiling heat transfer has received extensive attention. In this study, the heating surface with different roughness was adopted to conduct pool boiling experiments at different inclination angles. Based on the boiling curves and bubble images, the effects of inclination angle on the pool boiling heat transfer and critical heat flux were analyzed. When the inclination angle was bigger than 90°, the bubble size increased with the increase of inclination angle. Both the bubble departure frequency and critical heat flux decreased as the inclination angle increased. The existing theoretical models about pool boiling heat transfer and critical heat flux were compared. From the perspective of bubble agitation model and Hot/Dry spot model, the experimental phenomena could be explained reasonably. The enlargement of bubble not only could enhance the agitation of nearby liquid but also would cause the bubble to stay longer on the heating surface. Consequently, the effect of inclination angle on the pool boiling heat transfer was not conspicuous. With the increase of inclination angle, the rewetting of heating surface became much more difficult. It has negative effect on the critical heat flux. This work provides experimental data basis for heat transfer and CHF performance of pool boiling.

Performance Evaluation of IGCC Plants with Variation in Coal Rank and Coal Feeding System (탄종 및 석탄공급방식 변화에 따른 석탄가스화 복합발전 플랜트의 성능 평가)

  • 이승종;이진욱;윤용승
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.176-187
    • /
    • 1997
  • As a way to evaluate the performance of IGCC (Integrated Gasification Combined Cycle) processes, heating values of coal gas as well as plant efficiency were compared for different rank coals and coal feeding methods by employing the static process simulation technique. Performance of the process was compared with coal rank that was varied by three assorted bituminous coals and also by three subbituminous coals, in addition to the two types of feeding techniques, i.e., dry-feeding and slurry-feeding, that are utilized in entrained-bed coal gasifiers. For the verification of the simulation technique, simulated results were compared first with the actual pilot plant data published from Shell and Texaco. The simulation technique was, then, applied to other coals. Result from tests varying coal rank exhibits the trend of improving both heating content of the product gas and plant efficiency with increasing carbon content in coal. The effect of coal rank is more sensitive in slurry-feeding cases compared to the dry-feeding cases. In particular, considering notably lower values in gas heating value and plant efficiency calculated in the slurry-feeding case that uses a subbituminous coal, limited utilization of the slurry-feeding method for subbituminous coals can be expected. From the plant efficiency point of view, dry-feeding method resulted in higher simulated efficiency values by maximum 3% for subbituminous coals and ca. l% for bituminous coals.

  • PDF

Study on Semi-Dry Process Developement of BP's Sludge by Non-Heating Manufacture Method (비가열 제조법에 의한 BP슬러지의 반건조 제조공정 개발에 관한 연구)

  • Kim, Byeong-Ki;Kim, Jae-Hwan;Kang, Seok-Pyo;Kang, Hye-Ju
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.4
    • /
    • pp.313-319
    • /
    • 2015
  • This study relates to an investigation into semi-dry manufacturing process of BP sludge based on non-heating production method. In this study, we conducted a research into reduction of water content ratio which arose from mixture of BP by-products of high water content ratio(50% or higher) with industrial by-products to use such BP by-products as construction materials in large quantity. We measured the reduction rate of water content ratio at the feeding ratio of water content reduction agent(1:0.5) in BP by-products. The results showed that water content ratio was the lowest with 18.5% in the mixture of PA+CFA(1:0.5). Moreover, water content ratio ranged between approximately 9.2% and 11.4% at the age of 1 day to 2 days at the aging temperature of $20-30^{\circ}C$, suggesting that the water content ratio was in the range within 10% which was a level suitable for use as construction material in this study. Meanwhile, we compared and evaluated the physical properties of non-heated BP by-products based on post-aging pulverization method. The results showed that there was no significant difference, depending on pulverization method. When production efficiency and economic feasibility were taken into consideration, it was found desirable to use fine particle pulverizer or pin mill enabling continuous production.

Numerical Simulation for Local Circulation of Urban Area and Deposition Phenomenon (도시지역의 국지순환과 침적현상에 관한 수치모의)

  • 이화운;오은주;노순아;반수진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.773-787
    • /
    • 2003
  • There are variations in the temperature Held due to urban heat island and anthropogenic heating so that regional scale meteorological field is changed. Therefore we simulate and predict the regional climate change according to surface characteristics through regional meteorological model. This study investigates the regional meteorological field by urbanization that influences in local circulation system using CSU-RAMS and simulates dry deposition velocity (V$_{d}$) using PNU/DEM which includes surface characteristics (such as albedo, surface hydrology and rough-ness length etc.) with calculated meteorological field. During the summer, horizontal distributions of V$_{d}$ were simulated using CSU-RAMS and PNU/DEM at Busan metropolitan area. The estimated values of V$_{d}$ were larger in forest and agricultural areas than water areas since ozone with low water solubility is destroyed slowly at wet surface or water.water.

An Activity of Lowering Blood-glucose Levels Accoring to Preparative Conditions of Silkworm Powder (누에분말 제조 조건에 따른 혈당강하효과)

  • 류강선;이희삼
    • Journal of Sericultural and Entomological Science
    • /
    • v.39 no.1
    • /
    • pp.79-85
    • /
    • 1997
  • Bombyx mori, silkworm powder has been studied for blood-glucose lowering activity by National Sericulture & Entomology Research Institute(NSERI) and Kyung Hee University group in 1995. To obtain the optimum preparative condition of silkworm powder for lowering blood-glucose levels in postprandial time, blood-glucose lowering activity of mulberry & silkworm varieties were examined. In mulberry varieties, Samkwangjam showed the highest activity. Activity for lowering blood-glucose levels of autumn rearing silkworm was higher than that of spring silkworm and hybrid silkworm showed higher activity than that of parent silkworm. In the silkworm lines, Chinese lines showed higher activity than that of Japanese lines. In experiments to see the difference in blood-glucose lowering activity between either male and female or larvae and pupae, activity of larvae was higher than that of pupae and the male was higher than female. The heating dry and artificial diet showed lower than mulberry diet and normal freeze dry of the 5th instar 3rd day. Among the sericultural products, larvae showed the highest activity.

  • PDF

A Study on the Quality Properties of the Expansive For Dry-Shrinkage Compensation of the Floor Mortar (온돌바닥 모르터의 건조수축보상을 위한 팽창제의 품질특성 연구)

  • 이웅종;이종열;정연식;이순기;정성철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.155-160
    • /
    • 2000
  • In this paper, we investigated quality properties for the expansive of the CaO-$CaSO_4$ family which used to compensate dry-shrinkage in the floor mortar of On-Dol heating System. This experimental study established the mix condition with quantity of the expansive and is to investigate the relativity between the compress strength and the length change and the relativity between the chemical properties and the length change with the analysis of the physical and chemical properties. As a result of the study, the expansive is controlled by more the CaO than the $CaSO_4$. The relativity between the compress strength and the length change is expressed by exponential function, showing that if the expansive performance is increased, the compress strength is decreased. And the relativity between the chemical properties and the length change is only relative the quantity of the F-CaO among the chemical properties, is expressed by the second order function, showing that if the F-CaO is increased, the expansive performance is increased.

  • PDF

Drying Characteristics of 25 kW Class Industrial Dryer Adopting Mat Type Premixed Catalytic Burner (매트 형태의 예혼합 촉매 버너를 활용한 25 kW급 건조기의 성능 특성)

  • Ahn, Joon;Kim, Hyouck-Ju;Song, Kwang-Sup;Choi, Kyu-Sung;Song, Dae-Seok
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2856-2861
    • /
    • 2008
  • A catalytic burner has been developed to utilize thermal energy from the fossil fuel without nitrogen oxides (NOx) emission. The burner is shaped into a mat to maximize the heating surface. Premixed combustion has been developed to be used in a closed chamber, such as a radiation type industrial dryer. The burner yields the thermal energy in the form of thermal radiation in the infrared regime, which is proved to be effective to dry organic substances for low moisture condition. Thermal efficiency including the sensible heat is better correlated to the moisture compared to the dry rate.