• 제목/요약/키워드: Dry-bulb temperature

검색결과 114건 처리시간 0.032초

냉각수 계통의 운전변수가 중앙냉방시스템의 에너지소비량에 미치는 영향 (The Effects of Operational Conditions of Cooling Water System on Energy Consumption for Central Cooling System)

  • 안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.8-13
    • /
    • 2017
  • The effects of operational conditions of cooling water system on energy consumption for central cooling system are researched by using TRNSYS program. Cooling tower water pump flow rate, cooling tower fan flow rate, and condenser water temperature with various dry-bulb and wet-bulb temperatures are varied and their effects on total and component power consumption are studied. If the fan maximum flow rates of cooling tower is decreased, cooling tower fan and total power consumptions are increased. If the cooling tower water pump maximum flow rates is decreased, chiller and total power consumptions are increased. If condenser water set-point temperature is increased, chiller power consumption is increased and cooling tower fan power consumption is decreased, respectively.

조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 - (The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제38권2호
    • /
    • pp.1-8
    • /
    • 2010
  • 도시 옥외공간에서 조경 포장면의 종류에 따른 하절기 옥외공간의 온열쾌적성 차이 발생 여부를 차광과 통풍이 배제된 조건에서 실제 온도와 상대습도의 측정을 통하여 검증하였다. 잔디, 석재잔디블럭, 중공잔디블럭, 석재블럭, 사고석, 소형고압블럭, 점토벽돌, 나지, 쇄석, 수밀콘크리트 등 총 10가지 의 인공적으로 조성된 포장면을 대상으로 저항측정식 센서들을 이용하여 2009년 6월부터 9월까지 매 분 단위로 측정하고, 기상청 관측자료를 기준으로 일 최고 기온이 $30^{\circ}C$ 이상인 26일 동안의 정오부터 오후 3시까지의 자료를 분석하였으며, 주요 내용은 다음과 같다. 지면 온도는 포장재의 종류에 따라서 차이가 발생하였는데, 잔디면의 온도가 가장 높았고, 콘크리트의 온도가 상대적으로 낮은 것으로 나타났다. 전체 시험구의 평균 지면온도는 $40.1^{\circ}C$로 분석되었는데, 이는 기상대 관측 최고 기온보다 $9^{\circ}C$ 이상 높은 것이었으며, 최고 온도는 약 $50^{\circ}C$ 이상까지 상승하는 것으로 나타났다. 지면으로부터 1.2m 높이의 온열쾌적성지수인 습구흑구온도(Wet-Bulb Grlobe Temperature: WBGT)는 포장재에 따라서 통계적으로 유의한 차이가 있는 것으로 분석되었으며, 잔디포장면이 가장 높게 나타났고, 석재 또는 콘크리트블럭과 잔디를 혼합한 포장면이 가장 낮게 나타났다. 그러나 이들 측정값은 인간이 느끼는 쾌적한 온도 범위를 심각한 수준으로 넘어선 상태의 값으로 실제 환경에서의 체감 온열쾌적성과 직접 연관시키기는 곤란하다. 이러한 결과는 이상고온에 견디지 못하는 잔디의 생육 특성과 통풍과 차광이 배제된 시험구의 특성, 그리고 남중고도 가 높은 한낮의 데이터만을 분석 대상으로 삼은 점 등이 복합적으로 영향을 미친 결과로 해석되었다. 결론적으로 본 연구를 통해서 통풍과 차광이 배제된 하절기 한낮의 옥외공간에서는 인간이 체감하는 온열쾌적성에 포장재 변화가 미치는 영향은 미미하며, 오히려 통풍과 차광이 미치는 영향이 매우 중요하다는 것을 파악할 수 있었다.

Ecological Characteristics of Lycoris radiata with Habitat Types

  • Lee, Jeom-Sook;Ihm, Byung-Sun;Kim, Ha-Song
    • The Korean Journal of Ecology
    • /
    • 제26권5호
    • /
    • pp.247-250
    • /
    • 2003
  • The investigation of ecological characteristics of Lycoris radiata was carried out in flooding (site I), half flooding (site II) and dry stands (site III). Seasonal change of air temperature showed similar patterns and that of light intensity showed quite difference among three L. radiata stands. Seasonal change of soil water content showed a great difference among three L. radiata stands. The study area was dominated by Pinus densiflora, P. thunbergii and L. radiata communities. The number of bulb in 1. radiata increased in September with bulb formation and decreased in January. Bulb weight in L. radiata was different from each site. The numbers of blossom were 23, 13 and 9, respectively in site I, II and III. The length of wreath were 17.0, 13.0 and 11.0cm, respectively, the length of stamen were 7.0, 6.4 and 6.5 cm, respectively and the length of stalk were 60.0, 45.0 and 42.0 cm, respectively in site I, II and III. The leaf of L. radiata developed rapidly in site I with sufficient water supply and lower light intensity, the number and the length of rootlets increased considerably in site III with insufficient water supply and higher light intensity, and the ecological characteristics in site II was intermediate between site I and site III. There was no great difference between the numbers of rootlets in site I and site II, which were due to sufficient water supply in two stands.

건조전(乾燥前) 선별(選別)에 의한 Southern pine재(材)의 고온건조(高溫乾燥) (High-temperature Drying of Southern Pine Lumber by Green sorting)

  • 소원택
    • Journal of the Korean Wood Science and Technology
    • /
    • 제20권2호
    • /
    • pp.51-60
    • /
    • 1992
  • This study was performed to investigate the effect of green sorting before drying on the high-temperature drying characteristics of southern yellow pine dimension lumber(2"${\times}$6"${\times}$12'). To test the advantages of weight sorting, green lumber was seperated into heavy(above 55 1b), medium(50-55 1b), and light(below 50 1b)weight classes. Pieces in each weight class were subgrouped into high(above 35%) and low(below 30%) latewood groups. Groups were dried and seperated by a standard commercial high-temperature schedule; dry bulb temperature $245^{\circ}$ F, wet bulb temperature $180^{\circ}$ F, and air velocity 1200fpm. The results obtained were as follows; 1. There was a highly significant correlation between annual rings per inch(X) and percent-latewood(Y). The regression equation was Y=24, 5047+1.3272X. 2. There were highly significant correlations between either annual rings per inch($X_1$) or percent-latewood($X_2$) a.d specific gravity in green wood(Y). Their regression equations were Y=0.4260+0.0081$X_1$ and Y=0.3749+0.0029$X_2$, respectively. 3. Heavier weight charges dried more slowly than lighter weight charges. 4. Board-to-board variation in green or dry moisture content was less for all seperate weight classes than for unseperated control charges. 5. Lower latewood pieces had higher initial moisture content than higher latewood pieces, and then drying time for lower late wood pieces was longer than higher latewood pieces.

  • PDF

데시칸트제습기 선정프로그램 (Desiccant Dehumidifier Selection Program)

  • 김희재;박승태;유경록;이현주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.224-229
    • /
    • 2009
  • Performance curve of the desiccant rotor is an important information when developing and selecting the desiccant dehumidifier. The effective utilization of the energy is major capacity for the system and the desiccant performance curve is a design ability for a designer. By the rotor supply contract with DRI, ECO-DRY programs would be offered. Moreover, it could make remarkable progress in the desiccant system and energy saving. It is good to introduce the programs with the amicable help of DRI.

  • PDF

태양열 이용 소용량 제습냉방시스템 (Small-Capacity Solar Cooling System by Desiccant Cooling Technology)

  • 이대영;권치호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.154-156
    • /
    • 2008
  • A prototype of the desiccant cooling system with a regenerative evaporative cooler was built and tested for the performance evaluation. The regenerative evaporative cooler is to cool a stream of air using evaporative cooling effect without an inc6rease in the humidity ratio. It is comprised of multiple pairs of dry and wet channels and the evaporation water is supplied only to the wet channels. By redirecting a portion of the air flown out of the dry channel into the wet channel, the air can be cooled down to a temperature lower than its inlet wet-bulb temperature at the outlet end of the dry channels. Incorporating a regenerative evaporative cooler eliminates the need for deep dehumidification in the desiccant rotor that is necessary to achieve low air temperature in the system with a direct evaporative cooler. Subsequently, the regenerative evaporative cooler enables the use of low temperature heat source to regenerate the dehumidifier permitting the desiccant cooling system more beneficial compared with other thermal driven air conditioners. At the ARI condition with the regeneration temperature of $60^{\circ}C$, the prototype showed the cooling capacity of 4.4 kW and COP of 0.75.

  • PDF

생육기 온도상승이 극조생 양파의 생육 및 구 비대에 미치는 영향 (Impact of Elevated Temperature in Growing Season on Growth and Bulb Development of Extremely Early-Maturing Onion (Allium cepa L. cv. Singsingball))

  • 송은영;문경환;위승환;김천환;임찬규;오순자;손인창
    • 한국농림기상학회지
    • /
    • 제19권4호
    • /
    • pp.223-231
    • /
    • 2017
  • 본 연구는 미래 기후변화 시나리오에 근거하여 예측되는 온도 상승조건에서 노지 월동채소인 극조생 양파 '싱싱볼'의 생육 및 구 비대에 미치는 영향을 확인하고자 온도구배터널에서 수행하였다. 처리구는 대조구인 대기온도(일평균 $9.8^{\circ}C$) 조건, 온도상승구인 대기온도 $+2^{\circ}C$(일평균 $12.0^{\circ}C$)와 대기온도 $+5^{\circ}C$(일평균 $14.3^{\circ}C$) 조건 등 3수준으로 설정하였다. 생육기 온도 상승에 따른 양파의 생육을 조사한 결과, 대조구인 대기온도 조건에 비해 대기온도 $+2^{\circ}C$ 고온조건에서 자라는 양파가 초장도 길었고, 엽초경도 두꺼워졌으며, 총엽면적, 지상부 생체중 및 지상부 건물중이 증가되었다. 양파의 구 특성을 조사한 결과, 구경이나 구중은 생육후기로 갈수록 커지는 경향을 보였고, 대조구에 비해 대기온도 $+2^{\circ}C$ 고온조건에서 구 크기가 더 커지는 경향을 보였다. 구 비대 개시점인 구 비대지수도 대기온도 $+2^{\circ}C$ 고온조건에서는 타 조건에 비해 가장 빠른 경향을 보였다. 이상의 결과로 보아 대기온도보다 $2^{\circ}C$ 상승하였을 때 극조생 양파의 생육이 원활히 진행되고 수량이 증가되고 품질도 유지되겠으나, 대기 온도보다 $5^{\circ}C$ 이상 고온조건에서는 수량이 감소될 것으로 예측된다.

소공간 실험구의 차광과 통풍에 의한 기온저감 효과 (Air Temperature Decreasing Effects by Shading and Ventilation at Micro-scale Experiment Plots)

  • 김현철;우지근
    • 한국환경복원기술학회지
    • /
    • 제13권6호
    • /
    • pp.39-48
    • /
    • 2010
  • The purpose of this study was to analyze air temperature decreasing effects by shading and ventilation at micro-scale experiment plots, especially focused on the Wet Bulb Globe Temperature (WBGT) in outdoor spaces. To monitor the time-serial changes of Dry-bulb Temperature (DT), Globe Temperature (GT) and Relative Humidity (RH) in the wind blocking and shading conditions, Two hexahedral steel frames were established on the open grass field, the dimension of each frame was 1.5m(W)${\times}$1.5m(L)${\times}$1.5m(H). Four vertical side of one frame was covered by transparent polyethylene film to prevent wind passing through (Wind break plot; WP). The top side of the other frame was covered with shading curtain which intercept 95% of solar light and energy (Shading plot; SP). And, Another vertical steel frame without any treatment preventing ventilation and sunlight was set up, which represents natural conditions (Control plot; CP). The major findings were as follows; 1. The average globe temperature (GT) was highest at WP showing $50.94^{\circ}C$ and lowest at SP showing $34.58^{\circ}C$. The GT of natural condition (SP) was $42.31^{\circ}C$ locating the midst between WP and SP. The difference of GT of each plot was about $8-16^{\circ}C$, which means the ventilation and shading has significant effect on decreasing the temperature. 2. WP showed the highest average dry-bulb temperature (DT) of $38.41^{\circ}C$ which apparently differ from SP and CP showing $31.94^{\circ}C$ and $33.15^{\circ}C$ respectively. The DT of SP and CP were nearly the same. 3. The average relative humidity (RH) was lowest at WP showing 15.21%, but SP and CP had similar RH 28.79%, 28.02% respectively. 4. The average of calculated WBGT were the highest at the WP ($27.61^{\circ}C$) and the lowest at the SP ($23.64^{\circ}C$). The CP ($25.49^{\circ}C$) was in the middle of the others. As summery, compared with natural condition (CP), the wind blocking increased about $2.11^{\circ}C$ WBGT, but the shading decreased about $1.84^{\circ}C$ WBGT. So It can be apparently said that the open space with much shading trees, sheltering furnitures and well-delivered wind corridor can reduce useless and even harmful energy for human outdoor activity considerably in outdoor spaces.

여름철 산란계사 내 열환경인자 중 제어요소에 관한 연구 (Study on Control of Thermal Environmental Factors for Improvement of Productivity of Laying Hens in Summer)

  • 김성완;이태훈;차광준;;장홍희
    • 농업생명과학연구
    • /
    • 제53권2호
    • /
    • pp.121-129
    • /
    • 2019
  • 본 연구는 여름철 산란계의 더위 스트레스로 인한 생산성 저하에 영향을 미치는 열환경인자들 중 제어 요소를 결정하고 산란계의 생산성을 높일 수 있는 방안을 모색하기 위해 수행되었다. 경상남도에 위치한 산란계사에서 ISA Brown 품종의 산란계 48,451수를 공시하여 생산성 지표를 측정하였다. 또한 산란계사 내부에 온습도로거를 설치하여 건구온도와 상대습도를 여름이 시작되는 6월 19일부터 9월 7일까지 총 81일간 동안 측정하였다. 1일 평균온도, 1일 최고온도, 1일 최저온도, 1일 평균상대습도, 1일 최고상대습도, 1일 최저상대습도, 1일 평균THI, 1일 최고THI 그리고 1일 최저THI와 산란계의 생산성 지표 간의 상관관계를 분석하였다. 분석한 결과에 의하면, 1일 평균, 최고, 최저의 건구온도와 THI가 상승할수록 사료섭취량, 헨데이 산란율, 난중과 FCR은 낮아졌다(p<0.01). 반면, 음수량은 1일 평균, 최고, 최저의 건구온도와 THI가 상승할수록 증가하였다(p<0.001). 상대습도의 경우, 산란계의 생산성 지표에 대해 직접적인 상관관계를 가지지 않는 것으로 판단된다(p>0.05). 특이점으로는 폐사율의 경우, 1일 평균·최고 온도, THI와 1일 평균·최고·최저 상대습도와는 유의적인 상관관계를 가지지 않았지만, 1일 최저의 온도와 THI와는 상관관계를 갖는 것으로 분석되었다(p<0.05). 따라서, 여름철 산란계의 생산성을 향상시키기 위해서는 산란계사 내의 1일 평균, 최고, 최저의 건구온도와 THI를 가능한 낮추는 것이 필요하고, 특히 1일 최저온도를 산란계의 하한임계온도인 20℃에 근접하게 조성해주는 것이 유리할 것으로 판단된다.

냉각탑 성능 예측을 위한 프로그램 개발 (Program Development for the Prediction of Cooling Tower Performance)

  • 정재형;정재현;최영기
    • 설비공학논문집
    • /
    • 제26권3호
    • /
    • pp.130-136
    • /
    • 2014
  • The present study is performed to set up the framework of cooling tower performance predictions. The performance of mechanical forced draft cooling tower is directly related to the state of a nuclear power plant system, such as the condenser and evaporator. The main parameters related to the state of systems are as follows : wet bulb temperature, dry bulb temperature and absolute humidity. The performance evaluation of cooling tower must be considered at the power plant design. In this study, the toolkit developed by the American Cooling Tower Industry association (CTI) has been used for the framework construction. In order to validate the framework, it is being applied to the cooling tower constructed for the U.S. Nuclear Power Plant. The test results have shown good agreements with the cold water temperature on the cooling tower performance curves provided by manufacturers.