• Title/Summary/Keyword: Dry operation

Search Result 375, Processing Time 0.022 seconds

Development and testing of the hydrogen behavior tool for Falcon - HYPE

  • Piotr Konarski;Cedric Cozzo;Grigori Khvostov;Hakim Ferroukhi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.728-744
    • /
    • 2024
  • The presence of hydrogen absorbed by zirconium-based cladding materials during reactor operation can trigger degradation mechanisms and endanger the rod integrity. Ensuring the durability of the rods in extended time-frames like dry storage requires anticipating hydrogen behavior using numerical modeling. In this context, the present paper describes a hydrogen post-processing tool for Falcon - HYPE, a PSI's in-house tool able to calculate hydrogen uptake, transport, thermochemistry, reorientation of hydrides and hydrogen-related failure criteria. The tool extracts all necessary data from a Falcon output file; therefore, it can be considered loosely coupled to Falcon. HYPE has been successfully validated against experimental data and applied to reactor operation and interim storage scenarios to present its capabilities.

The development of LF power supply for dry scrubber

  • Kim Soo-Seok;Won Chung-Yuen;Choi Dae-Kyu;Choi Sang-Don
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.113-116
    • /
    • 2001
  • In this paper, the development of the LF power supply for dry scrubber is discussed. 1500kW, 100kHz LF power supply is designed and tested. The main power stage is used for the FB PWM inverter with an LC filter in the secondary circuit. The operation characteristics of LF power supply are verified by simulation and experimental results.

  • PDF

Development of CANDU Spent Fuel Bundle Inspection System and Technology (중수로 사용후연료 건전성 검사장비 개발)

  • Kim, Yong-Chan;Lee, Jong-Hyeon;Song, Tae-Han
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.1
    • /
    • pp.31-39
    • /
    • 2013
  • Nuclear fuel can be damaged under unexpected circumstances in a nuclear reactor. Fuel rod failure can be occurred due to debris fretting or excessive hydriding or PCI (Pellet-to-clad Interaction) etc. It is important to identify the causes of such failed fuel rods for the safe operation of nuclear power plants. If a fuel rod failure occurs during the operation of a nuclear power plant, the coolant water is contaminated by leaked fission products, and in some case the power level of the plant may be lowered or the operation stopped. In addition, all spent fuels must be transferred to a dry storage. But failed fuel can not be transferred to a dry storage. Therefore, the purpose of this study is to develop a system which is capable of inspecting whether the spent fuel in the storage pool is failed or not. The sipping technology is to analyze the leakage of fission products in state of gas and liquid. The failed fuel inspection system with gamma analyzer has successfully demonstrated that the system is enough to find the failed fuel at Wolsong plant.

Vitrification of Simulated Combustible Dry Active Wastes in a Pilot Facility

  • Yang, Kyung-Hwa;Park, Seung-Chul;Lee, Kyung-Ho;Hwang, Tae-Won;Maeng, Sung-Jun;Shin, Sang-Woon
    • Nuclear Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.355-364
    • /
    • 2001
  • In order to evaluate and finally optimize the vitrification condition for combustible dry active waste (DAW), dust and gas generation characteristics were investigated for PE, cellulose, and mixed waste Tests were conducted by varying the operation variables such as melter configuration, excess oxygen amount, and waste feeding rate. Results showed that dust generation characteristics were affected by the operation parameters and the melter's configuration is the dominant one. For all tested DAWs, dust generation was reduced by increasing the waste feeding rate and the excessive oxygen amount in the melter. Among waste types, dust amount was decreased by the order of mixed wastes, PE, and cellulose. Other parameters such as temperature variation and operation time have also affected the dust generation. The optimum condition for the DAW vitrification was determined as the melter's configuration equipped for minimizing the waste dispersion with 20 kg/h of waste feeding rate and 100% of excessive oxygen supply. CO gas concentration in the off-gas was immediately influenced by the combustion state in the melter, but showed similar trend as the dust generation. For the NOx production during the vitrification process, thermal NOx, which is generated from the Post Combustion Chamber (PCC), rather than fuel NOx was assumed to be dominant. The gas cleaning of efficiencies of the PCC, wet scrubber, and Selective Catalytic Reduction system (SCR) were found to be high enough to keep the concentration of pollutants (CO, NOx, SOx, HCI) in the stack below their relevant emission limits.

  • PDF

Status Analysis for the Confinement Monitoring Technology of PWR Spent Nuclear Fuel Dry Storage System (경수로 사용후핵연료 건식저장시스템의 격납감시 기술현황 분석)

  • Baeg, Chang-Yeal;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2016
  • Leading national R&D project to design a PWR spent nuclear fuel interim dry storage system that has been under development since mid-2009, which consists of a dual purpose metal cask and concrete storage cask. To ensure the safe operation of dry storage systems in foreign countries, major confinement monitoring techniques currently consist of pressure and temperature measurement. In the case of a dual purpose metal cask, a pressure sensor is installed in the interspace of bolted double lid(primary and secondary lid) in order to measure pressure. A concrete storage cask is a canister based system made of double/redundant welded lid to ensure confinement integrity. For this reason, confinement monitoring method is real time temperature measurement by thermocouple placed in the air flow(air intake and exit) of the concrete structure(over pack and module). The use of various monitoring technologies and operating experiences for the interim dry storage system over the last decades in foreign countries were analyzed. On the basis of the analysis above, development of the confinement monitoring technology that can be used optimally in our system will be available in the near future.

Review of Aging Management for Concrete Silo Dry Storage Systems

  • Donghee Lee;Sunghwan Chung;Yongdeog Kim;Taehyung Na
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.4
    • /
    • pp.531-541
    • /
    • 2023
  • The Wolsong Nuclear Power Plant (NPP) operates an on-site spent fuel dry storage facility using concrete silo and vertical module systems. This facility must be safely maintained until the spent nuclear fuel (SNF) is transferred to an external interim or final disposal facility, aligning with national policies on spent nuclear fuel management. The concrete silo system, operational since 1992, requires an aging management review for its long-term operation and potential license renewal. This involves comparing aging management programs of different dry storage systems against the U.S. NRC's guidelines for license renewal of spent nuclear fuel dry storage facilities and the U.S. DOE's program for long-term storage. Based on this comparison, a specific aging management program for the silo system was developed. Furthermore, the facility's current practices-periodic checks of surface dose rate, contamination, weld integrity, leakage, surface and groundwater, cumulative dose, and concrete structure-were evaluated for their suitability in managing the silo system's aging. Based on this review, several improvements were proposed.

A Study on Organic Solvent Exposure in Painting Operation of Automobile Manufacturing Industry (자동차 도장 작업장에서의 유기용제 폭로에 관한 연구)

  • 김영식
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.4
    • /
    • pp.10-16
    • /
    • 1994
  • A Study was performed in order to measure mixed organic solvent concentrations in air of painting operations during January 5-28, 1991. The mixed organic solvent concentrations were analyzed by the gas chromatography. The results were as follows: 1. The detection of organic solvent was highest in aromatic hydrocarbon(68%), and followed by aliphatic hydrocarbon (18%), and ketone (14%). 2. The detection of organic solvent by component category was highest in the grid class solvent (79.4%), and followed by the 3rd class solvent (20.6%). 3. Number of cases exceeding TLVS of mixed solvent level in air was highest on dipping operation (44%), and followed by spray operation (40%), dry and washing operation (33%), and adhensive operation (12%).

  • PDF

Analysis on the Dielectric Characteristics of Dry Air According to Pressures for Developing an Eco-friendly High Voltage Switchgear (친환경 고압배전반 개발을 위한 dry air의 압력별 절연내력특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1560-1565
    • /
    • 2011
  • The environmental pollution caused by green-house gases such as $CO_2$ and $SF_6$ has been becoming the main issue of industrial society. Many developed countries are making efforts to minimize the amount of $CO_2$ emission come from the operation of high voltage electrical apparatuses. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions. Nowadays, the study on the development of dry air insulated switchgear (DAIS) which is known as an eco-friendly electrical apparatus is in progress. A DAIS is advantageous for minimizing the effect of impurities and enhancing the dielectric characteristics over an air insulated switchgear (AIS) by applying constant pressure to an enclosed cubicle. Therefore, a study on the electrical insulation performance of dry air as a gaseous insulation medium is conducted in this paper to substitute a gas insulated switchgear (GIS) for DAIS. As results, it is verified that the AC dielectric characteristics of dry air are similar to those of air and the lightning impulse dielectric characteristics of dry air are superior to those of air at 1bar pressure condition. However, dry air is of inferior dielectric characteristics to $SF_6$ at 4bar pressure condition. Finally, it is suggested that the internal pressure of DAIS should be over 4bar pressure to develop a high voltage switchgear which has similar electrical performance to a conventional GIS. Also, the empirical formulae on calculating the maximum electric field intensity at sparkover of dry air are deduced by experiments according to pressures. It is expected that these results are helpful to design and develop a high voltage electrical apparatus.

A study on the comparison of operation for long & short time in the Dranco process (건식단상혐기성소화조 장.단기 운영의 비교연구)

  • Hong, Jong-Soon;Kim, Jae-Woo;Shin, Dae-Yewn
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.73-82
    • /
    • 2008
  • In this study, a dry single-phase anaerobic digestion process (Dranco system) was investigated to evaluate the optimum operational conditions. Several factors such as injection rate of organic waste, biogas production, $CH_4$ content in the biogas, pH of the sludge, $NH_3$-N and VFA concentration were investigated based on the operation of the digestion process for 2 months (short term) and 8 months (long-term). The operation results showed that a small quantity of food waste should be injected every week and that a 10% increase of the microorganism injection rate should be needed. However, normal operation was conducted after 11 weeks based on the designed quantity. The $CH_4$ content in the biogas was high at the beginning and the end of the food injection. However, it was low during week days. When the biogas production was high, the $CH_4$ concentration was low. The biogas production increased with an increase of the injection rate. $100m^3$/ton of biogas was produced from normal operation of the digestion process based on the designed quantity. The pH values of the digestion tank based on short-term operation ranged from 8 to 8.5. However, the pH values ranged from 7.45 to 8.15 after 4 weeks of long-term operation. The $NH_3$-N concentration of short-term operation ranged from 4,500 to 5,500 ppm and it gradually decreased to 2,000ppm after normal operation was commenced. For long-term operation, it was 5,000ppm initially and 3,800ppm after normal operation was commenced. The VFA concentration of sludge was less than 900ppm and 2,500ppm for short and long-term operations, respectively, after normal operation. Overall, the differences between sludge pH, $NH_3$-N and VFA concentrations may be due to the different types of microorganisms and the digestion ability of the microorganisms which exist in the accumulation of non digested organics. Moreover, it may be also caused by the type of food waste. Further investigation is needed to confirm these relationships.