• Title/Summary/Keyword: Dry heat

Search Result 919, Processing Time 0.031 seconds

Evaluation of Conventional Prediction Model for Soil Thermal Conductivity to Design Horizontal Ground Heat Exchanger (수평형 지중열교환기 설계를 위한 토양 열전도도 예측 모델 평가)

  • Sohn, Byong-Hu;Wi, Ji-Hae;Han, Eun-Seon;Lim, Jee-Hee;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.813-824
    • /
    • 2010
  • Thermal conductivity of soils is one of the most important parameters to design horizontal ground heat exchangers. It is well known that the thermal conductivity of soil is strongly influenced by its density and water content because of soil's particulate structure. This paper reviewed and evaluated some of the commonly used prediction models for thermal conductivity of soils with the experimental data available in the literature. Semi-theoretical models for two-component materials were found inappropriate to estimate the thermal conductivity of dry state sands. It came out that the model developed by Cote and Konrad gave the best overall prediction for unsaturated sands available in the literature. Also, a parametric analysis is conducted to investigate the effect of thermal conductivity and water content, soil type on the horizontal ground heat exchanger design. The analysis shows that a required pipe length for the horizontal ground heat exchanger is reduced with the increase of soil thermal conductivity and water content. The calculation results also show that the dimension of the horizontal ground heat exchanger can be reduced to a certain extent by using backfilling material with a higher thermal conductivity of solid particles.

  • PDF

UTILIZATION OF ENGINE-WASTE HEAT FOR GRAIN DRYING IN RURAL AREAS

  • Abe, A.;Basunia, M.A.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.957-966
    • /
    • 1996
  • An attempt was made to measure the availability of waste heat, released from the cooling system of a small engine, which can be utilized for grain drying. An engine powered flat-bed rough rice dryer was constructed and the performance of the dryer with available engine-waste heat was analyzed for 10 , 20, 30 and 40 cm rough rice bulk depths with a constant dryer base area of 0.81$m^2$/min. The waste heat was sufficient to increase the drying air temperature 7 to 12$^{\circ}C$ at an air flow rate of 8.8 to 5.7㎥/min, while the average ambient temperature and relative humidity were 24$^{\circ}C$ and 70%. The minimum energy requirement was 3.26 MJ/kg of water removed in drying a 40 cm deep grain bed in 14h. A forty to fifty centimeter deep grained seems to be optimum in order to avoid over-drying in the top layers. On the basis of minimum energy requirement (3.26 MJ/kg ) , an estimation was made that the waste heat harvest from an engine of a power range of 1 to 10.5PS can dry about 0.1 to 1 metric on of rough rice from 23% to 15% m.c. (w.b) in 12 h at an average ambient temperature and relative humidity of $25^{\circ}C$ and 80%, respectively. The engine-waste heated grain dryer can be used in the rural areas of non industrialized countries where electricity is not available.

  • PDF

Prediction of flow boiling heat transfer coefficient in horizontal channels varying from conventional to small-diameter scales by genetic neural network

  • Zhang, Jing;Ma, Yichao;Wang, Mingjun;Zhang, Dalin;Qiu, Suizheng;Tian, Wenxi;Su, Guanghui
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1897-1904
    • /
    • 2019
  • Three-layer back propagation network (BPN) and genetic neural network (GNN) were developed in this study to predict the flow boiling heat transfer coefficient (HTC) in conventional and small-diameter channels. The GNN has higher precision than BPN (with root mean square errors of 17.16% and 20.50%, respectively) and other correlations. The inputs include vapor quality x, mass flux G, heat flux q, diameter D and physical parameter φ, and the predicted flow boiling HTC is set as the outputs. Influences of input parameters on the flow boiling HTC are discussed based on the trained GNN: nucleate boiling promoted by a larger saturated pressure, a larger heat flux and a smaller diameter is dominant in small channels; convective boiling improved by a larger mass flux and a larger vapor quality is more significant in conventional channels. The HTC increases with pressure both in conventional and small channels. The HTC in conventional channels rises when mass flux increases but remains almost unaffected in small channels. A larger heat flux leads to the HTC growth in small channels and an increase of HTC was observed in conventional channels at a higher vapor quality. HTC increases inversely with diameter before dry out.

The appearance change and heat·moisture transfer properties of knitted fabric by yarn shrinkage (원사의 수축에 따른 다공성 편성물의 형태변화와 열·수분 전달특성)

  • Sang, Jeong-Seon;Park, Juhyun;Lee, Mee-Sik;Oh, Kyung Wha
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.6
    • /
    • pp.880-892
    • /
    • 2017
  • In this study, the appearance change and the heat moisture transfer properties of knitted fabric by yarn shrinkage were examined to obtain useful data on the development of thermo-sensitive functional materials. Eleven types of knitted fabric were knitted using highly bulky acrylic-blended yarn. After shrinking the specimens using dry heat treatment, the appearance change and thickness were measured. An HEC simulator was adopted for measuring the heat moisture transfer properties of specimens by yarn shrinkage. When holes were arranged vertically in the mesh structure, the specimens with 2,500 and 5,000 holes showed high percent change of hole area, appearance, and thickness. When holes were diagonally arranged in the mesh structure, the percent change of hole area in the specimen with 1,250 holes was larger than the one with 2,500 holes. However, the dimensional stability of the specimen with 2,500 holes was better because of its smaller appearance and thickness change. In the tuck structure, the percent change of hole area in the specimen with 625 and 416 holes was relatively large compared with the appearance and thickness change. Furthermore, the hole size in the tuck structure was smaller than that in the mesh structure but the percent change of hole area was larger. Therefore, it was proved that the tuck structure is more suitable than the mesh structure for developing thermo-sensitive functional materials. Heat moisture transfer property test verified that the change of hole area by yarn shrinkage enabled obtaining the thermal effect due to the distinct temperature difference in the inner layer.

A Case Study of 1 Taeeumin Patient Experiencing Hand Tremor, Heat Flash, and Dysarthria Treated Successfully with Yeoldahansotang (열다한소탕(熱多寒少湯)으로 양수(兩手) 진전(振顫), 안면(顔面) 상열감(上熱感), 어미삽(語微澁)을 치료한 태음인(太陰人) 환자 1예(例))

  • Lee, Ji-Won;Jang, Hyun-Su;Kim, Yun-Hee;Lee, Jun-Hee;Lee, Eui-Ju;Koh, Byeong-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.21 no.1
    • /
    • pp.254-262
    • /
    • 2009
  • 1. Objective This case study reports a Taeeumin patient experiencing hand tremor, heat flash, and mild dysarthria who improved with Yeoldahansotang medication. 2. Method The patient's subjective and objective symptoms were observed daily, and the VAS scores for the main symptoms (hand tremor, heat flash, and mild dysarthria) were recorded daily throughout hospitalization period. 3. Result The patient's general conditions improved by the end of hospitalization, and VAS score dropped dramatically from VAS 10, VAS 10, VAS 10 to VAS 0, VAS 0.5, VAS 3 for hand tremor, heat flash, and mild dysarthria, respectively. 4. Conclusion The patient responded well to Yeoldahansotang, one of the main medicaments for the Joyeol (dry-heat) symptomatic pattern, which indicates that Yeoldahansotang can be used to treat the Joyeol symptomatic pattern even when the textbook indications are not evident as long as the Joyeol pathology is recognizable from other symptoms.

  • PDF

Changes of antioxidative properties according to the heat-treatment of ginger extracts (생강추출물의 열처리에 따른 항산화성 변화)

  • 이진영;안명수
    • Korean journal of food and cookery science
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 1994
  • Oleoresin, 6-gingerol and 6,10-gingerol: 6-paradol= 1 : 1 mixture were extracted from ginger (Zingi-her of ficinale Roscoe) and changes of its antioxidant activity by heat-treatment were studed. Oleoresin was extracted with Ethanol-Ether and 6,10-gingerol : 6-paradol(1 : 1) and 6-gingerol were extracted with Hexane and Hexan : Ether= 1 : 1, respectively, and identified on the Thin-layer Chromatograpy (TLC) plate with the solvent system of Hexane Ether(1 : 4, v/v). And oleoresin was heat-treated during 0, 10, 30, 60, 120 minutes, and 6-gingercl and 6,10-gingerol . 6-paradol=1 : 1 were heat-treated during 0, 5, 10, 20, 40 minutes, respectively, at 140$^{\circ}C$ dry oven. To compare with antioxidant activity, oleoresins were added into soybean oil at 3fo level, 6-gingerol and 6,10-gingerol : 6-paradol= 1 : 1 at 0.1% level, BHT and TBHQ at 0.02% level, respectively. All the substrates treated were stored in a incubator at 45 2$^{\circ}C$ condition. The oxidative stability was estimated by the analysises of peroxide value and conjugated diene value during storage. The results were as follows: Antioxidant activity of oleoresins were considerably high and by heat-treatment were not decreased. 6-paradol was not show the antioxidant activity. 6,10-gingerol : 6-paradol=1 : 1 provided poor protection for soybean oil. Antioxidant activity of 6-gingerol was higher than 6,10-gingerol : 6-paradol=1 : 1 and by heat-treat-ment antioxidant activity was directly decreased. Relative antioxidant effectiveness(RAE) of each antio-xidant was compared. RhR was found to decrease as follow : TBHQ>oleoresin》BHT TBHQ》BHT>6-gingerol》6,10-gingerol : 6-paradol=1 : 1.

  • PDF

Design of Tissue-Transfer Container Using Thermoelectric Element Module

  • Park, Yong Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.66-69
    • /
    • 2017
  • The internal temperature of human-tissue transfers must be steadily maintained regardless of the external environmental changes. An ice pack and dry ice are the coolants for the transfer containers for which heat-insulating materials such as EPP (expended polypeopylene and EPS (expended polystrene) are used; however, changes of the external temperature/pressure and the melting of the coolants that is due to a long carriage result in changes of the internal temperature, and this makes it difficult to maintain the temperature. Accordingly, the thermoelectric element was used to design/manufacture a transfer container to maintain the internal temperature regardless of the external environmental changes. As a result of the measurement of the changes of the internal temperatures of the manufactured thermoelectric-element container and the EPS container over time, the internal temperature of the EPS container was increased, whereas the internal temperature of the thermoelectric-element container was maintained. The temperature of the distilled water that was poured into the containers indicated a pattern identical to that of the internal temperature.

A Study on Characteristics of Internal flow Pattern and Heat Transport Performance by Installing a Coil Insert in the Inside Wall of a Rotating Heat Pipe (Coil Insert에 의한 회전열파이프의 내부유동 및 열전달특성에 관한 연구)

  • 김선주;이진성;김철주;박이동
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.181-189
    • /
    • 1996
  • 회전열파이크는 전기모터, 고온가스터빈 등의 냉각에 이용함으로써 성능개선을 얻을 수 있다는 점에서 지난 20년 동안 많은 연구가 이루어져왔다. 그동안 내부벽면형상개발은 Taper를 설치하거나, 계단식 단면변화 또는 Impeller설치와 같은 기술들이 연구되었다. 본 연구는 회전 열파이프 용기내벽에 Coil Insert를 설치하여 응축액막 유동효과에 대한 가시화실험 및 열전달 성능실험을 통하여 그 특성을 검토하였고 아래와 같은 결과를 얻을 수 있었다. 1) Pool 영역에서는 Coil Insert에 의한 축방향 펌프효과가 매우 크며, 그 효과는 나선각이 클수록 크게 나타난다. 2) Coil Insert는 Pool에서 환상류로 천이를 촉진시키며, 나선각이 클수록 그 효과가 크게 나타난다. 3) Coil insert 열파이프의 열저항에 미치는 효과는 크지 않은 것으로 보인다. 4) Coil Insert에 의해 Dry-out한계의 증가가 예상되지만, 실험장치의 열부하한계에 의해 확인할 수 없었다.

  • PDF

Analysis of Solar Radiation and Heat-Efficiency in Semi-Greenhouse Type Solar-Dehumidification Lumber Dryer (반온실형(半溫室型) 제습(除濕).태양열(太陽熱) 목재(木材)드라이어의 일사량(日射量)과 열효율분석(熱效率分析)에 관(關)한 연구(硏究))

  • Lee, Hyoung-Woo
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.3-12
    • /
    • 1989
  • Semi-greenhouse type solar-dehumidification drying of oak was carried out to investigate the possibility to dry wood using solar energy in Korea. The energy balance equation was set up, considering all the energy requirements, and the solar radiation was calculated to analyze the efficiencies of solar dryer with and without the dehumidifier. The average temperature inside dryer and collector rose up to $52^{\circ}C$ and $70^{\circ}C$, respectively. The average daily total beam, diffuse, and ground-reflected radiations were 7.27MJ, 8.70MJ, and 0.33MJ on the roof and 2.08MJ, 4.84MJ, and 5.37MJ on the south wall collector, respectively. Heat efficiency of solar dryer was 14.04% with dehumidifier and 13.13% without dehumidifier. The energy required to remove 1g of water from wood was 0.0289MJ/g in solar-dehumidification drying and 0.0310 MJ/g in semi-greenhouse type solar drying.

  • PDF

Development of a Commercial-scale RDF Boiler with Chain type Stoker (실증규모 체인스토커식 RDF전용보일러 개발)

  • Choi, Yeon-Seok;Kim, Byung-Gil;Roh, Nam-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.813-816
    • /
    • 2009
  • A commercial-scale RDF boiler that its burning capacity is 400 kg-RDF/hr and steam production capacity is 2 ton/hr. It has a chain type stoker and waste heat recovery system. Heat exchanger is vertical water-pipe so that soot blowing and removal is convenient during operation. Dry scrubber, bag filter and activated carbon tower have been installed for the reduction of air pollutant gases and dust. Analysing data of pollutants from stack such as $SO_x$. $NO_x$ and dioxin shows so good results that the boiler system could comply the regulated emission limits.

  • PDF