• Title/Summary/Keyword: Dry heat

Search Result 920, Processing Time 0.031 seconds

Impacts of the Land-sea Distribution around Korean Peninsula on the simulation of East Asia Summer Precipitation (동아시아 여름 강수 모의에 있어 한반도 주변 해륙분포가 미치는 영향)

  • Cha, Yu-Mi;Lee, Hyo-Shin;Kwon, Won-Tae;Boo, Kyung-On
    • Atmosphere
    • /
    • v.17 no.3
    • /
    • pp.241-253
    • /
    • 2007
  • This paper investigates summer precipitation change in East Asia according to switching surface boundary condition over South Korea and Shantung. Simulations are carried out by ECHO-G/S for 20 years (1980-1999). Surface condition over both areas in ECHO-G/S is represented by ocean (OCN experiment). In OCN experiment, the summer precipitation is considerably underestimated around the Korean peninsula (the dry region) and overestimated over the eastern Tibetan Plateau (the wet region). It may be related that the lack of the heat sources from the unrealistically prescribed land-sea mask weakens northward expansion of rainband and the development of convective precipitation. Moreover the simulated rainband retreats before June in connection with the early genesis of summer monsoon circulation. The systematic bias of the summer precipitation over the dry and wet regions are reduced comparing with the OCN experiment when the land-sea masks over South Korea and Shantung are realistically considered as land (LND experiment). These improvements can be explained by the thermodynamical dissimilarity between land and ocean. Enhanced warming by switching the areas from sea to land has led to develop the thermal low over Yellow Sea with the cyclonic circulation. Thus, this cyclonic circulation supports moistures from the south to the dry region and blocks to the wet region. The heat transport from the land surface to atmosphere plays a key role in the developing convective precipitation in local scale and maintaining the precipitation and the rainband. Therefore, this results indicate that the design of the realistic land-sea distribution is required for the accurate simulation of the regional precipitation.

Establishment of Seed Treatment for Healthy Production of Peanut Sprout (청정 땅콩나물 생산을 위한 종자처리기술 확립)

  • Park, Eun-Ji;Lee, Gyu-Bin;Heo, You;Son, Beung-Gu;Choi, Young-Whan;Lee, Yong-Jae;Park, Young-Hoon;Suh, Jeong-Min;Kang, Jum-Soon
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.755-762
    • /
    • 2015
  • The present study was conducted to develop seed treatment for the production of healthy and clean peanut sprout. Dry heat treatment of peanut seeds reduced the incidence of the rot. The seed treatment condition at $52^{\circ}C$ for 10 h. was the most efficient without inhibiting seed viability significantly. Seeds were dark cultured at $27^{\circ}C$ for up to 9 days. The treatment of Indole-B and gibberellic acid influenced germination, T50, fresh, dry weight, hypocotyl length, hypocotyl length diameter, root length, number of lateral root and epicotyl of peanut sprout. There were no differences in the germinability of peanut seeds between gibberellic acid treatment methods but higher fresh weight was observed in the GA3 solution spray after 2 hour water soaking. The general growth and lateral root development of peanut sprouts were suppressed by Indole-B which is used for inhibiting root formation and promoting hypocotyls. The treatment of gibberellic acid promoted hypocotyl elongation, but it did not influence on the growth of hypocotyls and root system.

Water film covering characteristic on horizontal fuel rod under impinging cooling condition

  • Penghui Zhang;Bowei Wang;Ronghua Chen;G.H. Su;Wenxi Tian;Suizheng Qiu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4329-4337
    • /
    • 2022
  • Jet impinging device is designed for decay heat removal on horizontal fuel rods in a low temperature heating reactor. An experimental system with a fuel rod simulator is established and experiments are performed to evaluate water film covering capacity, within 0.0287-0.0444 kg/ms mass flow rate, 0-164.1 kW/m2 heating flux and 13.8-91.4℃ feeding water temperature. An effective method to obtain the film coverage rate by infrared equipment is proposed. Water film flowing patterns are recoded and the film coverage rates at different circumference angles are measured. It is found the film coverage rate decreases with heating flux during single-phase convection, while increases after onset of nucleate boiling. Besides, film coverage rate is found affected by Marangoni effect and film accelerating effect, and surface wetting is significantly facilitated by bubble behavior. Based on the observed phenomenon and physical mechanism, dry-out depth and initial dry-out rate are proposed to evaluate film covering potential on a heating surface. A model to predict film coverage rate is proposed based on the data. The findings would have reliable guide and important implications for further evaluation and design of decay heat removal system of new reactors, and could be helpful for passive containment cooling research.

Heat ,rind Moisture Transfer Properties of Fabrics for Korean Folk Clothes (시판 한복지의 열.수분이동 특성)

  • 성수광;성은정
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.6
    • /
    • pp.1071-1083
    • /
    • 1996
  • This study was carried out to obtain some fundamental data for designing thermally comfortable Korean folk clothes (KFC) which were classified into 4 groups according to seasons and materials. It was conducted to find the relationship among structural, thermal, and moisture transfer properties, and then the properties of heat and mositure transfer while changing thickness of air layer of selected similar fabrics with various thickness were examined. The summarized results of this study were as follows ; 1. The relationship between the structrual and thermal properties showed high positive correlation with thickness SE thermal insulation value (TIV), porosity & TIV. 2. The relationship between the structural and mositure transfer properties showed high negative correlation with thickness & moisture vapor permeability (Mp), porosity & Mp respectively. 3. The relationship between the heat and moisture transfer properites showed high negative correlation with qmax, air permeability (Ap), Mp & TIV while showed high positive with Ap & Mp respectively. 4. Resistance to dry heat transfer according to thickness of air layer for KFC was increassed rapidly up to 2 mm and above this increasing rate was reduced. Resistance to evaporative heat transfer was remarkable changes in 6∼8 mm but slowly in 6∼8 man. 5. Mioisture permeability index (i) according to thickness of air layer for KFC showed the greatest value at 2 mm but had not difference between groups according to thickness.

  • PDF

Catch-fire Temperature and Amount of Combustion-Heat on the Fuel of Miscanthus type (참억새(Miscanthus)燃料의 着火溫度 및 燃燒熱量)

  • Kim, Kwan-Soo;In-Soo Jang;Jae-Soon Lee
    • The Korean Journal of Ecology
    • /
    • v.18 no.4
    • /
    • pp.483-491
    • /
    • 1995
  • This study examined the relationship among catch-fire, burning, maximum temperature (MT), amount of combustion-heat (ACH), and combustive time (CT) in heating temperature treated with the same amount of each organ of Miscanthus. In the survey sites, about 19% of the areaswere covered by Miscanthus types, and the dry weight of Miscanthus and debris on the ground were 1,164 and 178 g/㎡, respectively. At 350℃ and 400℃, the rise of temperature by Culm type (culms and ears) and Leaf type (leaves and debris) were 90℃ and 82℃, respectively. At 350℃, durning time (BT) of culms-200, ears-200, ears-200, leaves-200 and debris-200 was 0-10’30”, 0-07’40”, 0-04’20”and 0-02’40”, and that at 400℃ was 0-01’20”, 0-00’50” 0-00’35”and 0-00’30”, respectively. BT was shorter at higher temperatures, and BT of Leaf type was shorter than that of Culm type. The amount of samples consumed was as follows: Culm type (culms-200 and ears-200) was 14.6g and 12.6g more than Leaf type (leaves-200 and debris-200) at 350℃ and 400℃, respectively. The total amount of combustion-heat (TACH) of samples was 5,859.7 kcal. The amount of mean combustion-heat generated from sample at 350℃ and 400℃ differed little: 727.6 kcal (24.9%) at 350℃ and 737.3 kcal (26.0%) at 400℃.

  • PDF

On the Steam Fog in the Gumi Reservoir of Nakdong River (낙동강 구미 보의 증기 안개에 관한 연구)

  • Kim, Hae-Dong;Cho, Chang-Bum;Seo, Kwang-Su
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.163-171
    • /
    • 2016
  • We analyzed the characteristics of fog formation in the Gumi Reservoir of Nakdong river with the field observation data for recent 2 years (1 April 2013~31 March 2015) collected by the national institute of meteorological research, KMA. In early morning, we frequently observe the steam rising from the water surface. The fog occurs from adding water vapor into the air. We call the fog as steam fog. Steam fogs occur when cold, dry air mixes with warm, moist air above a water surface. The steam fog appears mainly in autumn under the following conditions; (1) sensible heat is positive values ($10{\sim}20W/m^2$), (2) latent heat is more positive values ($25{\sim}35W/m^2$) than sensible heat, (3) cloudless nights with light winds (about 1.5 m/s), (4) under condition(3), mountainous winds easily blows into the reservoir.

Effect of Soil Thermal Conductivity and Moisture Content on Design Length of Horizontal Ground Heat Exchanger (토양 열전도도와 수분함량이 수평형 지중열교환기 설계 길이에 미치는 영향)

  • Sohn, Byong-Hu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.1
    • /
    • pp.21-31
    • /
    • 2012
  • This paper reviewed and evaluated some of the commonly used prediction models for thermal conductivity of soils with the experimental data. Semi-theoretical models for two-component materials were found inappropriate to estimate the thermal conductivity of dry state soils. It came out that the model developed by Cote and Konrad gave the best overall prediction results for unsaturated soils available in the literature. However, it still needs to be improved to cover a wider range of soil types and degrees of saturation. In the present study, parametric analysis is also conducted to investigate the effect of soil type and moisture content on the horizontal ground heat exchanger design. The analysis shows that horizontal ground heat exchanger pipe length is reduced with the increase of soil thermal conductivity and water content. The calculation results also show that horizontal ground heat exchanger size can be reduced to a certain extent by using backfilling material with a higher thermal conductivity of solid particles.

The Effect of Coolant Boiling on the Molten Metal Pool Heat Transfer with Local Solidification

  • Cho, Jea-Seon;Kune Y. Suh;Chung, Chang-Hyun;Park, Rae-Joon;Kim, Sang-Baik
    • Nuclear Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.34-45
    • /
    • 2000
  • This study is concerned with the experimental test and numerical analysis of the heat transfer and solidification of the molten metal pool with overlying coolant with boiling. In the test, the metal pool is heated from the bottom surface and coolant is injected onto the molten metal pool. Experiments were performed by changing the test section bottom surface temperature of the metal layer and the coolant injection rate. The two-phase boiling coolant experimental results are compared against the dry test data without coolant or solidification of the molten metal pool, and against the crust formation experiment with subcooled coolant. Also, a numerical analysis is performed to check on the measured data. The numerical program is developed using the enthalpy method, the finite volume method and the SIMPLER algorithm. The experimental results of the heat transfer show general agreement with the calculated values. The present empirical test and numerical results of the heat transfer on the molten metal pool are apparently higher than those without coolant boiling. This is probably because this experiment was performed in concurrence of solidification in the molten metal pool and the rapid boiling of the coolant. The other experiments were performed without coolant boiling and the correlation was developed for the pure molten metal without phase change.

  • PDF

An Experimental Study of the Air-side Particulate Fouling of Finned-Tube Heat Exchangers of Air Conditioners by using Accelerated Particle-Loading System (파울링 형성 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 실험적 연구)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱;옥주호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.802-808
    • /
    • 2003
  • The air-side particulate fouling of the HVAC heat exchangers degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. The purpose of this study is to investigate the fouling characteristics using accelerated particle loading system. The fouling characteristics are analyzed as functions of a dust concentration, a face velocity and a wet or dry surface condition. The pressure drop increases with increasing test operation and reaches constant asymptotic level. For the saturated condition due to particle loading, the pressure drop across the slitted finned-tube heat exchangers at the face velocity of 1 m/sec increases up to 57% and the cooling capacity decreases about 2%. The cooling capacities are not affected greatly by the presence of the fouling deposits if the thickness of the fouling deposits can not change substantially the flow pattern through the fins.

Strength Properties of Bisphenol A-Type Epoxy-Modified Mortars under Various Curing Conditions (각종 양생조건에 따른 비스페놀 A형 에폭시수지 혼입 모르타르의 강도성상)

  • Kim, Wan-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.55-59
    • /
    • 2009
  • The epoxy resin without hardener can harden by a ring-opening reaction in the presence of the alkalies produced by the hydration of cement in epoxy-modified mortars and concretes. This paper investigates the effect of curing conditions on the strength improvement of polymer-modified mortars using bisphenol A-type epoxy resin without hardener. The polymer-modified mortars using epoxy resin are prepared with various polymer-cement ratios, and subjected to ideal, water, dry and heat cures. In the heat cure, the epoxy-modified mortars are sealed or unsealed with a PVDC (polyvinylidene chloride) film. The epoxy-modified mortars are tested for flexural and compressive strengths at desired curing methods. The microstructures of the epoxy-modified mortars are also observed by scanning electron microscope. The effects of curing conditions on the strength development of the epoxy-modified mortars are examined. From the test results, the marked effectiveness of the heat cure under the PVDC film sealing against the development of the strength of the epoxy-modified mortar without the hardener is recognized. The flexural and compressive strengths of 7-day-90℃ heat-cured, PVDC film-sealed epoxy-modified mortars without hardener reach 7 to 17MPa and 24 to 44MPa respectively, and are two to three times of Unmodified mortar. Such high strength development of the epoxy-modified mortars may be achieved by the dense microstructure formation by cement hydrates and the hardening of the epoxy resin in the mortars.

  • PDF