• Title/Summary/Keyword: Drug monitoring

Search Result 611, Processing Time 0.032 seconds

Dieticians' Perceived Performance Level and Obstructive Factors of HACCP System among Elementary School Food Services in Gyeongbuk Province (경북지역 초등학교 영양(교)사의 학교급식 HACCP 시스템 수행 수준 및 장애요인 인식)

  • Yang, Ji Hye;Sung, Bo Mi;Kim, Mi Hwa;Jung, Hyun Sook;Cha, Myeong Hwa;Ryu, Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1774-1784
    • /
    • 2014
  • The purpose of this study was to determine obstructive factors and performance level of the HACCP system among elementary schools in Gyeongbuk province. E-mail survey targeted 320 dieticians, and recovery rate was 74.1%. Consequently, 227 responses were analyzed. The questionnaire was composed of 58 items under four sections (general characteristics, dieticians' perceived HACCP performance level, dieticians' perceived CCP performance level, and obstructive factors of HACCP system implementation). The item with the highest rate of HACCP performance level was 'HACCP training for foodservice employees in schools ($4.02{\pm}0.70$)' while the lowest counterpart was 'implementation of HACCP team meeting, reporting, and maintenance ($2.74{\pm}0.99$)'. The performance level of the item 'HACCP training for foodservice employees in schools' was perceived as highest when the number of students eating school meals was greater than 1,101 (P<0.05). Moreover, CCP 4 ($4.44{\pm}0.53$) and CP 5 ($4.44{\pm}0.51$) showed the best performance, whereas CCP 1 showed the lowest performance level ($3.90{\pm}0.60$). Therefore, reinforcement of hygiene instruction in menu planning is perceived as necessary. CCP 1, CCP 6 (P<0.05), and CCP 3 (P<0.001) showed significant differences in performance based on the number of students eating school meals. Further, according to results regarding obstructive factors of HACCP system execution, 'general factor' was the most severe obstructive factor in the application of HACCP ($3.46{\pm}0.62$). Among the 'factors pertaining to dieticians', the item 'hardship of proper monitoring and micro-management due to overwhelming workload' was most influential ($3.46{\pm}0.96$). Furthermore, the item 'low budget allocation by educational offices ($3.90{\pm}0.88$)' was influential among the 'factors pertaining to school administrations'. In conclusion, the results of this research can help solve obstructive factors of elementary school food services and provide knowledge that is essential for the proper implementation of HACCP.

A Study on the Labeling Efficiency and Cytotoxicity of Hepatocyte-targeting Galactosylated Chitosan Compounds (간세포 지향성 Galactosylated Chitosan 화합물의 표지 수율 향상 및 세포 독성에 대한 연구)

  • Kim, Dae-Weung;Jeong, Hwan-Jeong;Kim, Eun-Mi;Kim, Se-Lim;Kang, Yun-Hee;Kim, Min-Woo;Kim, Chang-Guhn;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.5
    • /
    • pp.278-283
    • /
    • 2005
  • Purpose: In prior study, we synthesized $^{99m}Tc$-galactosylated chitosan (GC) and performed in vivo biodistribution study, showed specific targeting to hepatocyte. The aim of this study is to evaluate the labeling efficiency and cytotoxicity of modified galactosylated chitosan compounds, galactosyl methylated chitosan (GMC) and HYNIC-galactosylated chitosan (GCH). Materials and Methods: GC, GMC and GCH were synthesized and radiolabeled with $^{99m}Tc$. Then, they were incubated for 6 hours at room temperature and human serum at $37^{\circ}C$. Labeling efficiencies were determined at 15, 30 m, 1, 2, 3 and 6 h after radiolabeling. To evaluate cytotoxicity, MTT assay was performed in HeLa and HepG2 cells. Results: In comparison with them of $^{99m}Tc$-GC labeling efficiencies of $^{99m}Tc$-GMC were significantly improved (100, 97 and 89%) in acetone and 96.3, 95.8 and 75.6% in saline at 15 m, 1 and 6 h, respectively). Moreover, $^{99m}Tc$-GCH showed more improved labeling efficiencies (>95% in acetone and human serum and >90% in saline at 6 h). In MTT assay, cytotoxicity was very low and not different from that of controls. Conclusion: These results represent that these compounds are radiochemically compatible radiopharmaceuticals, can be used in hepatocyte specific imaging study and in vivo gene or drug delivery monitoring.

The Effect of Midazolam As Sedative Agent in Bronchoscopy (기관지내시경 검사시 전처치로서 Midazolam의 효과)

  • Lee, Sang-Haak;Hyun, Dae-Sing;Lee, Sook-Young;Kim, Seok-Chan;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.612-618
    • /
    • 2002
  • Background : Bronchoscopy is an important diagnostic and a therapeutic tool in chest medicine. However, most patients feel that a bronchoscopy is an unpleasant procedure, and it is important to sedate the patients appropriately, particularly where repetitive examinations are required. Midazolam is a sedative drug with amnestic qualities and a rapid 2 hour half-life. This study have attempted to determine the safety, appropriate dosage, and the effect of midazolam premedication in patients who underwent a bronchoscopy. Methods : One hundred and eighty consecutive patients undergoing bronchoscopy were enrolled in this study. The patients received a midzolam doses of 0.03 mg/kg, 0.06 mg/kg, or a placebo. An additional dose of lidocaine, the total number of coughs, and the duration of the procedures were recorded with monitoring the the blood pressure, heart rate, and oxygen saturation. The level of satisfaction was assessed by the patient, bronchoscopist, and the nurse. Results : The blood pressure, pulse rates, oxygen saturation, number of coughs, lidocaine dose, and procedure time in the 3 groups were similar. There was a trend for the midazolam 0.03 mg/kg group to satisfy bronchoscopists more than the other two groups. The nurses' acceptability was lower in the midazolam 0.06 mg/kg group than the other groups. The patients' acceptablity was greater in both the midazolam 0.03 mg/kg and 0.06 mg/kg groups than in the control group. Conclusion : Sedation with low doses of intravenous midazolam is a safe technique for fiberoptic bronchoscopy with a low morbidity and high acceptable to patients and bronchoscopists.

Use of Antimicrobial Agents for the Treatment of Inpatients in Chonbuk National University Hospital (전북대학교병원 입원환자에서의 항생제 사용 실태)

  • Song, Jae Ho;Kim, Jung Soo
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.2
    • /
    • pp.225-232
    • /
    • 2000
  • Purpose : The use antimicrobial agents is one of the important strategies for the treatment and prophylaxis of microbial infections. But injudicious abuse and misuse of antimicrobial agents is problem to add an extra weight on medical fee, increase of resistant bacteria and side effects according to the antibiotic use. This study was performed to establish the pertinent use of antimicrobial agent in Chonbuk National University Hospital(CNUH). Characteristics of antibiotics use was analysis by reviewing the medical records of patients admitted to CNUH during the period of May 1998. Methods : One thousand eight hundred and thirty three patients were enrolled in this study(medical division 1,014 cases, surgical division 819 cases). Medical records were retrospectively reviewed to classify the rate of antibiotics use, name of antibiotics used, appropriateness of antibiotics use. Results : The overall rate of antibiotic usage in CNUH was 67.2%(1,231/1,833), showing higher rate in surgical division(89.6%) compare to that of medical division(49.0%). Among 1,231 patients to whom antimicrobial agents were given, only 125(10.2%) were treated with single antimicrobial agents. 311(25.3%) were treated with two antimicrobial agents, and 795(64.5%) patients received 3 or more antibiotics. ${\beta}$-lactams(56.4%) were most frequently used followed by aminoglycosides(35.3%), the others(4.9%) and quinolons(3.4%). Amoxicillin-clavulanate was the mostly commonly used antibiotics followed by amoxicillin and unasyn. Prophylactic use of antibiotics was carried in seven hundred six patients(57.4%), mostly in surgical division, which can be considered somewhat inappropriate in the initiation time and duration of antibiotic use. Conclusion : Importance of monotherapy and appropriate prophylactic antibiotic use should be emphasized. Strategies of antibiotics use, such as restriction of drug use, continuous monitoring system, flow sheet system should be considered to reduce antibiotics use and establish the appropriate use of antibiotics as well as inhibiting the occurrence of resistant strains.

  • PDF

Mutation Patterns of gyrA, gyrB, parC and parE Genes Related to Fluoroquinolone Resistance in Ureaplasma Species Isolated from Urogenital Specimens (비뇨생식기계 검체로부터 분리된 Ureaplasma 종의 Fluoroquinolone 내성과 관련된 gyrA, gyrB, parC, parE 유전자의 돌연변이 양상)

  • Cho, Eun-Jung;Hwang, Yu Yean;Koo, Bon-Kyeong;Park, Jesoep;Kim, Young Kwon;Kim, Sunghyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.74-81
    • /
    • 2016
  • Ureaplasma species can normally colonize in the bodies of healthy individuals. Their colonization is associated with various diseases including non-gonococcal urethritis, chorioamnionitis, neonatal meningitis, and prematurity. In 2012, the sum of the resistant and intermediate resistant rates of Ureaplasma spp. to ofloxacin and ciprofloxacin was 66.08% and 92.69%, respectively. DNA point mutations in the genes encoding DNA gyrase (topoisomerase II) and topoisomerase IV are commonly responsible for fluoroquinolone resistance. Each enzyme is composed of two subunits encoded by gyrA and gyrB genes for DNA gyrase and parC and parE genes for topoisomerase IV. In the current study, these genes were sequenced in order to determine the role of amino acid substitutions in Ureaplasma spp. clinical isolates. From December 2012 to May 2013, we examined mutation patterns of the quinolone resistance-determining region (QRDR) in Ureaplasma spp. DNA sequences in the QRDR region of Ureaplasma clinical isolates were compared with those of reference strains including U. urealyticum serovar 8 (ATCC 27618) and U. parvum serovar 3 (ATCC 27815). Mutations were detected in all ofloxacin- and ciprofloxacin-resistant isolates, however no mutations were detected in drug-susceptible isolates. Most of the mutations related to fluoroquinolone resistance occurred in the parC gene, causing amino acid substitutions. Newly found amino acid substitutions in this study were Asn481Ser in GyrB; Phe149Leu, Asp150Met, Asp151Ile, and Ser152Val in ParC; and Pro446Ser and Arg448Lys in ParE. Continuous monitoring and accumulation of mutation data in fluoroquinolone-resistant Ureaplasma clinical isolates are essential to determining the tendency and to understanding the mechanisms underlying antimicrobial resistance.

Characteristics of Methicillin-resistant Staphylococcus aureus Nasal Colonization Among Neonatal Unit Staff and Infection Control Measures (일개 병원 신생아실 근무 의료인에서 시행한 비강 내 MRSA 집락의 특성 및 전파예방에 관한 보고)

  • Kim, Dong Hwan;Kim, Sun Mi;Park, Ji Young;Cho, Eun Young;Choi, Chang Hee
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.2
    • /
    • pp.131-141
    • /
    • 2009
  • Purpose : In February 2007, an outbreak of methicillin-resistant Staphylococcus aureus (MRSA) skin and soft tissue infections occurred in two newborns in the neonatal unit of Sahmyook Seoul Hospital. We performed this study to investigate the characteristics of MRSA nasal carriage among neonatal unit staffs and the effective infection control measures. Methods : Nasal swab specimens were obtained from the neonatal unit staff for the presence of MRSA. MRSA-colonized staffs were offered decolonization therapy with oral trimethoprim-sulfamethoxazole or 2% mupirocin ointment. Every 2-4months after decolonizaton, repeat nasal swab specimens were obtained. Also, samples from the neonatal unit environment and room air were collected. Results : Successful decolonization was achieved in 92% of the cases in 2 weeks after decolonization therapy, but most of the staffs were recolonized after several months. The nature of antibiotic susceptibility was changed from multi-drugsusceptible to multi-drug-resistant. The most frequently contaminated objects were dressing carts, computer keyboards, bassinets and washbowls. In environmental cultures using the settle microbe count method, the colony counts were decreased significantly at the last study period compared with the first study period in the neonatal room, breastfeeding room, service room, and dressing room (P <0.05). Conclusion : Effective control of sustained MRSA transmission within an institution may require prompt identification, treatment, and monitoring of colonized and/or infected staffs. However, nasal decolonization therapy may induce multi-drugresistant MRSA infection and had no effect on decreasing the MRSA nasal carriage rate in our study. Other factors might be more important, such as improving staff education, increasing hand hygiene practices, and environmental sterilization for controlling MRSA infections.

  • PDF

Risk Analysis of Inorganic Arsenic in Foods (식품 중 무기비소의 위해 분석)

  • Yang, Seung-Hyun;Park, Ji-Su;Cho, Min-Ja;Choi, Hoon
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.4
    • /
    • pp.227-249
    • /
    • 2016
  • Arsenic and its compounds vary in their toxicity according to the chemical forms. Inorganic arsenic is more toxic and known as carcinogen. The provisional tolerable weekly intake (PTWI) of $15{\mu}g/kg$ b.w./week established by the Joint FAO/WHO Expert Committee on Food Additives (JECFA) has been withdrawn, while the EFSA panel suggested $BMDL_{0.1}$ $0.3{\sim}8{\mu}g/kg\;b.w./day$ for cancers of the lung, skin and bladder, as well as skin lesions. Rice, seaweed and beverages are known as food being rich in inorganic arsenic. As(III) is the major form of inorganic arsenic in rice and anaerobic paddy soils, while most of inorganic arsenic in seaweed is present as As(V). The inorganic arsenic in food was extracted with solvent such as distilled water, methanol, nitric acid and so on in heat-assisted condition or at room temperature. Arsenic speciation analysis was based on ion-exchange chromatography and high-performance liquid chromatography equipped with atomic absorption spectrometry and inductively coupled plasma mass spectrometry. However, there has been no harmonized and standardized method for inorganic arsenic analysis internationally. The inorganic arsenic exposure from food has been estimated to range of $0.13{\sim}0.7{\mu}g/kg$ bw/day for European, American and Australian, and $0.22{\sim}5{\mu}g/kg$ bw/day for Asian. The maximum level (ML) for inorganic arsenic in food has established by EU, China, Australia and New Zealand, but are under review in Korea. Until now, several studies have conducted for reduction of inorganic arsenic in food. Inorganic arsenic levels in rice and seaweed were reduced by more polishing and washing, boiling and washing, respectively. Further research for international harmonization of analytical method, monitoring and risk assessment will be needed to strengthen safety management of inorganic arsenic of foods in Korea.

Clozapine Administration Potentiate Platelet Activation in Patients with Schizophrenia : Retrospective Study (클로자핀을 투여한 조현병 환자에서 혈소판 활성 증가에 관한 후향적 연구)

  • Kim, Hyun-Ah;Lee, Jong Wook;Kim, Seung-Jun;Oh, Hong-Seok;Im, Woo Young;Kim, Ji-Woong
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.26 no.2
    • /
    • pp.188-193
    • /
    • 2018
  • Objectives : Clozapine is a widely prescribed antipsychotic drug for schizophrenia and is known to increase the risk of cardiovascular disease due to its metabolic side effects. However, little is known about the effect of clozapine on the platelet activation, another important factor in the development of cardiovascular disease. In this study, we tried to investigate the effect of clozapine on platelet activity in patients with schizophrenia by comparing the mean platelet component (MPC) values before and after the clozapine administration. Methods : A retrospective review of medical records of patients with schizophrenia, who newly started clozapine treatment from September 1st, 2003 to April 30th, 2007 at the Department of Psychiatry, Konyang University Hospital in Republic of Korea was performed. The final statistical analysis included 14 participants. Bayer ADVIA $120^{(R)}$ system was used to measure MPC. Results : Among the 14 participants, five subjects were males (28.60%), and ten subjects were females (71.40%). The mean age of participants was $37.50{\pm}11.64years$. Average of duration of illness was $91.00{\pm}93.96months$, with the mean dosage of clozapine taken by participants at the time of the last blood test was $337.50{\pm}109.52mg$. The mean MPC measurement before and after receiving clozapine was $26.12{\pm}2.22g/dL$ and $25.14{\pm}2.08g/dL$ respectively. Wilcoxon signed rank test showed that there was a statistically significant decrease in MPC levels after clozapine administration (V=16, p=0.024). Conclusions : Decreased MPC levels after clozapine administration implies that clozapine may increase platelet activation which could have an adverse effect on the occurrence of thromboembolic disease. Our findings also suggest that careful monitoring of the risk factors of cardiovascular diseases, such as platelets activity, is necessary when administering clozapine.

Investigation of Unintentionally Hazardous Substance in Commercial Herbs for Food and Medicine (유통 식약공용농산물 중 비의도적 유해물질 오염도 조사)

  • Seo, Mi-Young;Kim, Myung-Gil;Kim, Jae-Kwan;Jang, Mi-Kyung;Lee, Yu-Na;Ku, Eun-Jung;Park, Kwang-Hee;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.6
    • /
    • pp.453-459
    • /
    • 2018
  • This study was performed to investigate the contamination levels of heavy metals (such as lead, cadmium, arsenic and mercury) and aflatoxin (such as $B_1$, $B_2$, $G_1$ and $G_2$) in commercial herbs for food and medicine. The concentrations of the heavy metals were measured by the ICP-MS and a mercury analyzer. The aflatoxins were analyzed by a HPLC-florescence coupled with photochemical derivatization. The detection ranges of the lead, cadmium, arsenic and mercury were found to be 0.006~4.088 mg/kg, 0.002~2.150 mg/kg, ND~0.610 mg/kg and ND~0.0139 mg/kg respectively. Among the total samples, the 3 samples (2.6%) were not suitable for the specification of cadmium by the MFDS (Ministry of Food and Drug Safety). The 13 samples of the total 117 samples were aflatoxin positive (11.1%). The amount of aflatoxin $G_1$ was $0.7834{\mu}g/kg$ in the Puerariae Radix and aflatoxin $G_2$ were $0.3517{\mu}g/kg$, $0.4881{\mu}g/kg$ in two samples of the Glycyrrhizae Radix et Rhizoma, respectively. The aflatoxins $B_2$ and $G_1$ were simultaneously detected in the 10 Angelicae Gigantis Radix. The detection ranges of aflatoxins $B_2$ and $G_1$ were $0.2324{\sim}1.0358{\mu}g/kg$ and $0.7552{\sim}1.6545{\mu}g/kg$ respectively in Angelicae Gigantis Radix. The results of the current study suggest that continuous monitoring is needed for the proactive management of commercial herbs for food and medicine safety.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF