• Title/Summary/Keyword: Droplet surface temperature

Search Result 123, Processing Time 0.021 seconds

Characteristics for Nanofluid Droplet Evaporation on Heated Surface at Boiling Temperature of Base Liquid (비등점의 가열 표면에서 나노유체 액적의 증발 특성)

  • Kim, Dae Yun;Jung, Jung-Yeul;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.20 no.4
    • /
    • pp.236-240
    • /
    • 2015
  • This study aims to experimentally investigate the evaporation characteristics of nanofluid droplet on heated surface at boiling temperature of DI-water. In particular, textured surface was used to examine the effect of wettability on evaporation. At the initial stage of evaporation process, dynamic contact angle (DCA) of nanofluid droplet with 0.01 vol.% concentration on textured surface rapidly increased over its equilibrium contact angle by generated large bubble inside the droplet due to lower wettability. However, contact angle of nanofluid droplet with higher concentration on textured surface decreased with surface tension. In addition, total evaporation time of droplet on textured surface was considerably delayed due to reduction of contact area between droplet and solid surface. Thus, evaporation characteristics were highly affected by the nanofluid concentration and surface wettability.

An Experimental Study of Breakup of Impinging Droplets on a Hot Surface (표면 충돌 액적의 분열에 관한 실험적 연구)

  • Ko, Y.S.;Chung, S.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.5
    • /
    • pp.85-92
    • /
    • 1994
  • Characteristics of breakup of a liquid droplet impinging on a hot surface has been investigated experimentally by using decane fuel. Factors influencing droplet breakup are surface temperature, impinging velocity, droplet diameter and incident angle. Droplets impinging on a hot surface begins to breakup at $220{\sim}235^{\circ}C$. This temperature varies with impinging Velocity, droplet diameter and incident angle. For wall temperature of $220{\sim}245^{\circ}C$ and above $270^{\circ}C$, breakup probability increases as impinging velocity increases showing S shape curve. For $245{\sim}265^{\circ}C$, a local minimum heat transfer rate occurs. In this temperature range, breakup probability shows nonmonotonous behavior as functions of impinging velocity. As droplet diameter decreases, impinging velocity required for droplet breakup increases. An optimum impinging angle for droplet breakup exists which are found to be about $75^{\circ}$.

  • PDF

ATOMIZATION OF LIQUID DROPLET BY IMPINGEMENT ONTO THE HOT SURFACE (고온벽면 충돌에 의한 미립화)

  • Jeon, In-Kon;Lee, Jun-Baek;Jeon, Heung-Shin
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.738-744
    • /
    • 2000
  • The breakup behaviors of impinging droplet on a hot surface are studied experimentally. The droplets are produced by the dripping method and the breakup behaviors of liquid droplet are recorded by photographs. Experimental conditions are, droplet diameter di : 2.5, 3.2 [mm], weber number : $30{\sim}140$, surface temperature : $28^{\circ}C(room\;temperature){\sim}450^{\circ}C$. Water is used to liquid. As weber number of droplet increases, a liquid sheet, which is formed after the impingement on a hot surface, is disintergrated by the dynamical effect. But at low weber number, it has effected by thermodynamical effect. The breakup behaviors of droplet are divided into three patterns with weber number and surface temperature, non-disintegration, transition and disintegration region. Further, these boundary values are affected by the hot surface temperature and weber number. SMD of breakup droplets are calculated in according to surface temperatures and weber number. The minium SMD of breakup droplets are observed at weber number 65.49, temperature $250^{\circ}C$ and weber number 99.08, temperature $350^{\circ}C$.

  • PDF

Evaporation Cooling of Single Droplet on a Heated Solid Surface (가열된 고체표면에 부착된 단일 액적의 증발냉각)

  • Yu, Gap-Jong;Bang, Chang-Hun;Kim, Jeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.845-852
    • /
    • 2001
  • The characteristics of evaporation cooling of single droplet on a heated surface were studied experimentally. The two kinds of heater modules were tested to measure cooling characteristics of metal surface (high conductivity) and Teflon surface (low-energy surface, low conductivity). The results showed that time averaged heat flux during droplet evaporation increased exponentially with initial surface temperatures of brass, copper and steel. The heat flux and evaporation time did not varied with metal conductivities. However, the temperature drop after the deposition of droplet was larger on Teflon than on the metals. Thus, the correlation of interface temperature between liquid droplet and metal surface was proposed as a function of the initial surface temperature of heating materials, which could be applied to both metal and non-metal ones.

A Study on the Behavior of a Droplet Impacting onto a Heated Surface (고온 벽면과 충돌하는 단일 액적의 거동에 관한 연구)

  • Kang, Bo-Seon;Lee, Dong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.871-880
    • /
    • 1999
  • In this paper an experimental study is presented of the problem of dynamic behavior of a water droplet impinging upon a heated surface. The experiments are mainly focused on the effects of impinging angle of a droplet and surface temperature on the impact dynamics of the droplet. It Is clarified that the droplet exhibits much different behavior depending on the normal momentum of an impinging droplet before impact. At surface temperature In the nucleate boiling regime. the disintegration of a droplet doesn't occur, whereas the deforming droplet adheres to the surface. The spreading and contraction of the liquid film is repeated a couple of times for the horizontal surface but the expanded droplet just slips without noticeable contraction for the inclined surfaces. In the film boiling regime, the impinging droplet spreads over the surface as a liquid film which is separated from the surface by produced vapor. Depending on the magnitude of the normal momentum of the droplet the disintegration into the several irregular shapes of liquid elements occurs for the horizontal and 30o-inclined surfaces, whereas the impinging droplet for the 60o-inclined surface doesn't break up and tends to recover the original spherical shape.

Effects of Surface Roughness on Evaporation Cooling of Single Water Droplet in Radiative Fields (복사장 내에서 충돌면의 표면조도가 단일액적 증발냉각에 미치는 영향)

  • 유갑종;박철우;장충선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.467-474
    • /
    • 2004
  • This paper presents the results of an experimental investigation for the effect of radiant heat on the evaporation cooling of water droplet in the process of fire extinguishing. The experiments are mainly focused on the surface temperature, the surface roughness and the droplet diameter. The range of surface temperature is T$_{s}$ =80-14$0^{\circ}C$, surface roughness is R$_{a}$=0.08-0.64 ${\mu}{\textrm}{m}$ and the droplet diameter is $\Phi$=3.0 mm in the radiation. The results show that the evaporation time is shorter for the larger surface roughness and the volume of droplet increased when the surface roughness is 0.64 ${\mu}{\textrm}{m}$ at the surface temperature 127$^{\circ}C$. When the surface roughness is 0.64 ${\mu}{\textrm}{m}$, the heat flux is larger than the surface roughness is 0.08 ${\mu}{\textrm}{m}$ at the surface temperature 81$^{\circ}C$.>.>.

The study of a fire fighting characteristic by a Single Evaporating Droplet in the case of a fire of military enclosure space (군사용 밀폐공간내의 화재시 단일 증발액적에 의한 방재특성 연구)

  • 이진호;방창훈;김정수
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.207-217
    • /
    • 2000
  • A fire fighting characteristic by a single evaporating droplet in the case of a fire of military enclosure space was studied experimentally. Transient cooling of solid surface by water droplet evaporation has been investigated through controlled experiments using a heated brass cylinder. Quantitative predictions of droplet evaporation time and in-depth transient temperature distribution in solid have been made. The particular interest was in the removal of thermal energy from the heated cylinder by evaporative cooling. A $10{\mu}1$ single droplet is deposited on a horizontal brass surface with initial temperatures in the range of $90^{\circ}C{\sim}130^{\circ}C.$ The results can be summarized as follows; Evaporating droplet was divided into three different configuration. Evaporation time was predicted as a function of initial surface temperature ($t_c=492.62-6.89T_{s0}+0.0248T_{s0}^2).$ The contact temperature was predicted as a function of initial surface temperature( $T_{i}$=0.94 $T_{s0}$+1.4), The parameter ${\beta}_o$ was predicted as a function of initial surface temperature( ${\beta}_0$ : 0.O0312 $T_{s0}+0.932$)>)>)

  • PDF

Behavior of an Impinging Droplet on a Solid Surface with a Variation of Liquid Temperature (액체 온도 변화에 따른 평판 충돌 액적의 거동에 관한 연구)

  • Lee Dong Jo;Park Byung Sung;Chung Jin Taek;Kim Ho Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.330-339
    • /
    • 2005
  • An experimental study on the behavior of droplets impinging on a solid flat surface was carried out in the present study. Breakup of a liquid droplet impinging on a solid surface has been investigated experimentally for various liquids with different properties. The liquid droplet temperature and incident angle were chosen as major parameters. Liquid droplet temperature and incident angle varied in the range from $-20{\circ}C\;to\;30{\circ}C\;and\;from\;30{\circ}\;to\;60{\circ},$ respectively. It was found that the variation of droplet temperature influences upon the mean diameter and uniformity of droplets which were bounced out from the solid surface. With increase of incident angle the dispersion mass fraction increases, causing the decrease of liquid film flow rate. As the liquid temperature increases, dispersion mass fraction increases since the surface tension decreases.

Evaporation Cooling of Water Droplet on Aluminum with Various Surface Roughness and Droplet Diameter in Conductive Condition (전도조건 하에서 표면조도와 액적 직경의 변화에 따른 알루미늄의 액적 증발 냉각)

  • Jang, C.S.;Choi, W.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.6
    • /
    • pp.375-382
    • /
    • 2005
  • This paper presents the results of experimental investigation for the effect of heat conduction on the evaporation cooling of water droplet in the process of heat treatment. The experiments are mainly focused on the surface temperature, the surface roughness and the droplet diameter at aluminum. The range of surface temperature is from $80^{\circ}C$ to $140^{\circ}C$, surface roughness is from $R_a=0.18{\mu}m$ to $R_a=1.36{\mu}m$ and droplet diameter is from 2.4 mm to 3.0 mm. The results show that the total evaporation time is shorter for the larger surface roughness, the time averaged heat flux has maximum value for the larger surface roughness and exist the critical heat flux. The total evaporation time has a big influence on the evaporation region for the smaller droplet size, but the total evaporation time has not influence on the nuclear boiling region.

Behavior of Impinging Droplet on a Solid Surface for the Variation of Fuel Temperature (연료 온도 변화에 따른 평판 충돌 액적의 거동에 관한 연구)

  • Lee, Dong-Jo;Kim, Ho-Yong;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.167-173
    • /
    • 2003
  • An experimental study on the behavior of droplets impinging on a solid flat surface was carried out in the present study. Breakup of a liquid droplet impinging on a solid surface has been investigated experimentally for various fuels with different properties. The fuel temperature and incident angle were chosen as major parameters. And fuel temperature and incident angle varied in the range from $-20^{\circ}C$ to $30^{\circ}C$ and from $30^{\circ}$ to $60^{\circ}$, respectively, were investigated. It was found that the variation of fuel temperature influences upon droplet mean diameter which were bounced out from the solid surface. As the increases of incident angle, the break-out mass flow rate increases. This causes the decrease of liquid film flow rate. The larger incident angle gives less liquid film flow rate.

  • PDF