• Title/Summary/Keyword: Droplet sizing

Search Result 15, Processing Time 0.023 seconds

Automatic Color Recognition System for Stockigt Sizing Test (II) - Application of the automatic recognition principle of red coloration for developing the novel automatic system - (스테키히트 시험용 자동발색인지 시스템 개발을 위한 기초 연구(II) -자동 발색 인지 원리를 적용한 발색 자동인지시스템-)

  • Kim, Jae-Ok;Kim, Chul-Hwan;Park, Chong-Yawl;Kwon, Oh-Chul
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.1 s.109
    • /
    • pp.73-81
    • /
    • 2005
  • Stockigt sizing test, which is readily affected by individual tester's bias as well as testing conditions in recognizing red coloration, had to be modified to improve its reliability and reproducibility. The novel testing system with the automatic recognizing program of red coloration was developed with the auxiliary equipments including an automatic liquid dispenser and a specimen shifter. The analysis program used a hue value of a droplet image in recognizing a point of time on red coloration instead of RGB values that are not similar to human perception of color. Hue was more sensitive in recognizing the red coloration of a droplet than the other two factors, Saturation and Value. During the test, the program records the time consumed up to a specific hue value of a droplet on a specimen. Differently from the conventional test, the automatic test could obtain a reliable and reproducible sizing degree with a minor error. Furthermore, the Stockigt sizing degree measured by the automatic system showed great correlations with contact angle and Hercules sizing degree. It means that such great correlations will contribute to the development of an integrated measuring system capable of predicting contact angle, surface tension, surface energy and Hercules sizing degree of paper and paperboards through the Stbckigt sizing test. It was meaningful to note that the automatic system for Stbckigt sizing test might be able to used to predict contact angle, Hercules and Cobb sizing degree, based upon the high correlation coefficients.

Visualization of Gasoline Sprays Via a Simultaneous Inaging of Fluorescence and Scattering Lights (형광, 산란광 동시 촬열법을 이용한 가솔린 분무의 거동에 관한 연구)

  • 원영호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.167-174
    • /
    • 1997
  • The penetration depth and the size distribution of the droplets of fuel sprays are important in the operation of spark-ignition MPI engines. A fluorescence/scattering image technique for droplet sizing was applied to measure th edroplet size distribution in non-evaporating gasoline sprays. The fluorescence and scattering lights were imaged simultaneously by the two-dimensional visualization system composed of a laser sheet, a doubling prism, optical filters, and a CCD camera. Quantitative droplet size distributions were extracted from evaluating the ratio of the two light densities. The mean droplet size measured by the fluorescence/scattering technique was compared with the result obtained by the enlarged photographs of droplets. The fluorescence/scattering image technique also gives the useful information of the characteristics of droplet impingement in a inclined wall.

  • PDF

Automatic $St{\ddot{o}}ckigt$ Sizing Test Using Hue Value Variation of a Droplet

  • Kim, Jae-Ok;Kim, Chul-Hwan;Lee, Young-Min;Kim, Gyeong-Yun;Shin, Tae-Gi;Park, Chong-Yawl
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.227-230
    • /
    • 2006
  • The $St{\ddot{o}}ckigt$ sizing test of the most-commonly used sizing tests is easily influenced by the individual testers' bias in recognizing red coloration. Therefore the test had to be modified to improve its reliability and reproducibility by automated recognition of a coloration procedure during testing. In order to achieve this, all measured variables occurring during the $St{\ddot{o}}ckigt$ test was first be analyzed and then reflected in the new automatic system. Secondly, the most important principle applied was to transform the RGB values of the droplet image to hue (H), saturation (S) and value (V) respectively. This is because RGB cannot be used as a color standard, owing to RGB's peculiarity of being seriously affected by the observer's point of view. Therefore, the droplet color had to be separated into three distinct factors, namely the HSV values, in order to allow linear analysis of the droplet color. When the average values of the vectors calculated during color variation from yellow to brown were plotted against time, it was possible to determine the vector value of hue, the most sensitive factor among HSV, at the specific time by differentiation of a function when it exceeds the critical point. Then, the specific time consumed up to the critical point was regarded as the $St{\ddot{o}}ckigt$ sizing degree. The conventional method took more time to recognize an ending point of coloration than the automatic method, and in addition the error ranges of the conventional sizing degrees on the specific addition points of AKD were wider than those of the automatic method.

  • PDF

Development of Droplet Sizing Technique in Spay Flow (분무유동에서 입경 계측기법의 개발)

  • Yang, Chang-Jo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.67-73
    • /
    • 2007
  • Recently, fire extinguishing systems based on water mists have been attracting public attentions in marine engineering. Performance of fire extinguishing systems is very strongly influenced by the size and distribution of spayed water mists. Therefore, the present study has developed droplet analyzing method based on image processing. The morphological technique based on partial curvature information of pre-processed images with relaxation method was adopted for recognition and separation of overlapped particles. Tested results showed that the present method may be reliable for the analysis of the size and distribution of droplets in spray flow of fire extinguishing systems based water mists.

Development of a Novel System for Measuring Sizing Degree Based on Contact Angle(I) - Development of a Novel Principle for Automatic Measurement of Contact Angle - (접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제1보) -자동 접촉각 측정 원리의 개발 -)

  • 이찬용;김철환;최경민;박종열;권오철
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.43-52
    • /
    • 2003
  • The new principle to measure a sizing degree by a contact angle was developed using an automatic determination of the 3-end point coordinates of the water droplet on a sheet, which could diminish the operator's bias during measurement. A constant amount of water was first placed on a sample sheet by a water dispenser, and then an image of the liquid droplet was captured by a digital camera and then transmitted to a computer. The program measuring for contact angle extracted a liquid contour by Gaussian function combined with a 8-direction chain code. The Euclidean equation was applied to the binary image of the liquid contour in order to measure the diameter of the contour. Finally, the contact angle of the liquid was calculated by using the diameter and the top coordinates. In addition, a surface free energy of the sample sheet and an elapsed time taken up to the complete absorption into the sheet were simultaneously measured with the contact angle.

2-D Simultaneous Measurements of Velocity and Diameter of Diesel Spray Droplets by Novel Interferometric Laser Imaging for Droplet Sizing (ILIDS) Method

  • Ryul, C.-S;Y. Moriyoshi;M. Yamada
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.263-268
    • /
    • 2004
  • The characteristics of Diesel spray droplets, such as the velocity and the diameter were simultaneously measured by using an improved Interferometric Laser Imaging for Droplet Sizing method. The experiments were carried out using an accumulator-type unit injector system and a constant-volume vessel. Two dimensional cross-section photographs of sprays were also taken using a double-pulsed Nd- YAG laser sheet and a linear array CCD camera. As a result, interesting relations between the droplets diameter and the velocity were found.

Study on the Flow Characteristics of the Epoxy Resin w.r.t. Sizing Materials of Carbon Fibers (탄소섬유 사이징에 따른 에폭시 수지 유동 특성에 관한 연구)

  • Lim, Su-Hyun;On, Seung Yoon;Kim, Seong-Su
    • Composites Research
    • /
    • v.31 no.6
    • /
    • pp.379-384
    • /
    • 2018
  • This paper aims to study flow characteristics of epoxy resin w.r.t. the sizing agents treated on the carbon fibers which have the same surface morphologies before sizing treatment. Dynamic contact angle (DCA) was measured to evaluate wettability of a single carbon fiber. Wicking test and Vacuum Assisted Resin Transfer Molding (VARTM) were performed to find relation between DCA measurement results and impregnation characteristics. In addition, surface properties of the carbon fibers such as surface free energy and chemical compositions were measured and interfacial shear strength (IFSS) between the carbon fiber and the resin were experimentally characterized by using micro-droplet tests. According to these experimental results, the sizing agent for carbon fibers should have appropriate level of surface free energy and good chemical compatibility with the resin to reconcile resin flow characteristics and interfacial strength.

Automatic Color Recognition System for Stockigt Sizing Test (I) - Bias of Stockigt sizing test based on observer's subjectiveness - (스테키히트 시험용 자동 발색 인지 시스템 개발을 위한 기초연구(I) - Stockigt 사이즈도 시험법에 영향을 주는 요인 분석 -)

  • 김재옥;김철환;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • One of the most frequently used method for measurement of the degree of sizing (viz., hydrophobicity) is the Stockigt test. However, the Stockigt test was influenced by various factors such as dropping height, dropping amount, dropping speed and viewing angle. The resultant data of the sizing degree on the same specimen also varied according to different testers. Thus, the Stockigt test should be modified to be regarded as a highly reliable and reproducible standard method. For modifying the Stockigt test, it was required to quantify red coloration by reaction between 1% ferric chloride and 2% ammonium thiocyante during Stockigt testing. The cameras capturing the serial images during the red coloration process were the CMOS (Complementary Metal Oxide Semiconductor)-type and CCD (Charge Coupled Device)-type cameras. For measurement based on KS M 7025, the CCD-type camera must be used due to its high resolution, and on the other hand, for measurement based on Tappi Useful Method 429, the CMOS-type camera may be used owing to its low resolution. It was needed to covert the RGB values of a droplet image into HSV(Hue, Saturation, and Value) values because the human eyes are much closer to HSV than RGB. Among HSV values, the Hue value was accepted as the most reliable index consistent with the red coloration process by excluding the surrounding conditions such as light, tester's movement etc.

Development of Separation Algorithm of Overlapped Particles in Spay Flow (분무 유동에서 중첩 인자 분리 알고리즘의 개발)

  • Yang, C.J.;Kim, J.H.;Cho, D.H.;Oh, J.H.;Lee, Y.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.118-119
    • /
    • 2005
  • Recently, fire extinguishing systems based on water mists have been attracting public attentions in marine engineering. Performance of the fire extinguishing systems is influenced by the size and distribution of spayed water mists. Droplet analyzing method based on image processing technique for measuring droplet size and distribution has been developed. The morphological method based on partial curvature information of pre-processed images was adopted for recognition and separation of overlapped particles. Tested results show that the present method may be reliable for the analysis of the size and distribution of droplets produced by water mist spay flow.

  • PDF

선박용 미분무 소화기노즐 수적 입자경 계측기법 개발

  • Kim, Tae-Hyeong;Kim, Jeong-Hwan;Yang, Chang-Jo;O, Jong-Hwan;Choe, Jang-Un
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.307-308
    • /
    • 2006
  • Recently, fire extinguishing systems based on water mists have been attracting public attentions in marine engineering. Performance of the fire extinguishing systems is influenced by the size and distribution of spayed water mists. Droplet analyzing method based on image processing technique for measuring droplet size and distribution has been developed. The morphological method based on partial curvature information of pre-processed images was adopted for recognition and separation of overlapped particles. Tested results show that the present method may be reliable for the analysis of the size and distribution of droplets produced by water mist spay flow.

  • PDF