• 제목/요약/키워드: Droplet Flow Rate

검색결과 154건 처리시간 0.023초

강제대류 및 핵비등영역에 있어서 액적유량과 분무냉각 열전달의 상관관계에 관한 연구 (Correlation of Droplet Flow Rate and Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제13권3호
    • /
    • pp.143-148
    • /
    • 2008
  • In the present study, the correlation between the Nusselt number and Reynolds number was developed for forced convection and nucleate boiling region in spray cooling. Also the effect of droplet subcooling on spray cooling heat transfer was investigated. Full cone spray nozzles were employed for spray cooling experiment, and water and FC-77 were used for developing the correlation. From the experimental results, the correlation between the Nusselt number and Reynolds number based on droplet-flow-rate was developed. The correlation shows good predictions with ${\pm}30%$ error for water and FC-77.

  • PDF

전기 분무 시스템의 전기수력학적 특성 (Electrohydrodynamic Characteristics of an Electro-Spray System)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제23권8호
    • /
    • pp.1031-1039
    • /
    • 1999
  • Electrospraying comprises the generation of liquid droplets by applying a high voltage to the surface of a liquid. By monitoring the current and the flow rate it was possible to obtain a stable cone jet mode in a given condition. In this work the liquid contained NaCl particles resolved in distilled water. The NaCl particles increased concentration of the ionized solution and thus increased electrical conductivity of the liquid, which was inversely proportional to the flow rate in the cone jet mode. A number of sprayed droplets were sampled and dried enough, and then the size of NaCl particles were measured. The measured droplet diameter was a little larger than two theoretical diameters, Rayleigh diameter and mobility diameter.

Urea-SCR에 적용되는 이유체 노즐의 분무특성에 관한 실험적 연구 (Experimental Study on Spray Characteristics of Twin Fluid Nozzle in Urea-SCR)

  • 박형선;홍정구
    • 한국분무공학회지
    • /
    • 제22권2호
    • /
    • pp.96-102
    • /
    • 2017
  • In order to reduce the NOx, SCR technology is most suitable. In this study, we focused on studying the injector part of urea-SCR system. When stoichiometric 1 mole of urea is injected, 2 moles of $NH_3$ are created. $NH_3$ causes a SCR reaction by reacting with NOx. However, urea is decomposed by the side reaction of coming out HNCO, deposit formation is formed. In this study, it was to design a nozzle that can spray the optimal spray flow rate. Test nozzle used in this experiment is efferverscent type. The result of the experiment, liquid flow rate was confirmed to be that they are dominated by the exit orifice diameter. The area ratio is defined by ratio of the area of exit orifice hole and that of aerorator. The droplet size was measured by varying the area ratios. In addition, it was also confirmed that there is no change of the liquid flow rate and air flow rate to change the aerorator at the same exit orifice. Further, It was confirmed that the droplet size was relatively uniform even though the area ratio was different. Finally, there is little change in the SMD that air flow rate increases in 0.3 or more ALR.

공기 압력과 전기장이 접목된 액적 분무에 관한 연구 (Atomization of Liquid Via a Combined System of Air Pressure and Electric Field)

  • 황상연;성백훈;변도영
    • 한국가시화정보학회지
    • /
    • 제12권2호
    • /
    • pp.9-12
    • /
    • 2014
  • Conventional electrospray and air spray methods have the vulnerabilities of limited flow rate (throughput) and droplet size, respectively. Since high throughput with uniform size of droplet is required for various applications, an improved technique should be adopted. Here, we report a combined system of an air pressure and an electric field and evaluate the atomization performance of it. The air flow allowed applying high flow rate range and the electric field reinforced the atomization process to generate fine droplets. A correlation between two forces was investigated by comparing the droplet produced by each method. The atomized droplets were measured and visualized by image processing and a particle image velocimetry (PIV). The quantitative results were achieved from the parametric space and the effect of both forces was analyzed. The motion of charged droplets followed the outer electric field rather than the complex vortex in the shear layer so that the droplets accelerated directly toward the grounded collector.

입자간의 상호작용으로 인한 입자의 운동 및 증발에 미치는 영향 (Influences on the Droplet Dynamics and Evaporation due to Closely Spaced Droplet Interaction)

  • 이효진
    • 대한기계학회논문집
    • /
    • 제16권9호
    • /
    • pp.1770-1779
    • /
    • 1992
  • The present study investigated dynamically and thermally interacting droplets in a closely spaced tandem array. By measuring the velocity and diameter of the droplet traveling along the isothermal vertical plate drag coefficients and vaporization rates of droplets at certain location were obtained. During the experiment initial droplet spacings were less than 5, and initial droplet diameters were ranged between 280 .mu.m and 700 .mu.m Drag coefficients on closely spaced droplets were placed far below the standard drag coefficient, for which it was caused turbulence induced from aforelocating droplets also narrow spaces among droplets restricted heat transfer to droplets from hot gas flow. In addition evaporated vapor entrapted between droplets was major factor in delaying droplet vaporization. With the experimental results the drag coefficient was correlated with respect to Reynolds number for the droplet as follows : $c_{D}$ =2.4/Red.$^{0.37}$

노즐특성에 따른 MIST-COOLING 열전달에 관한 실험적 연구 (The Effect of Nozzle Characteristics on the Mist-Cooling Heat Transfer)

  • 이진원;강영규;백병준;박복춘
    • 열처리공학회지
    • /
    • 제5권3호
    • /
    • pp.171-178
    • /
    • 1992
  • The effect of nozzle characterristics on the mist-cooling heat transfer was investigated under the various flow conditions. Two different types of twin fluid nozzle were used, one is a $90^{\circ}$ angle tip nozzle with needle and the other is a $90^{\circ}$ angle tip non-needle nozzle. The cooling rate from the heated surface was measured and obtained the boiling curve as a function of surface temperature. An immersion sampling was employed for the measurement of droplet size of the spray. As a result of this experiment, the liquid sheet type nozzle shows better atomization when the mass ratio Mr>2.0, and collects more liquid droplets on the heated surface that results in better cooling effect. It was found that the maximum heat flux and heat transfer coefficient increased with increase in the volumetric flow rate, whereas the maximum heat flux decreased with increase in spray distance. The cooling effect depends upon the amount of collected droplet and droplet size, but it strongly depends upon the amount of collected droplet.

  • PDF

배관 재질 손상에 미치는 액적충돌침식의 영향에 대한 연구 (A Study for the Effect of Liquid Droplet Impingement Erosion on the Loss of Pipe Flow Materials)

  • 김경훈;조연수;김형준
    • 한국분무공학회지
    • /
    • 제18권1호
    • /
    • pp.9-15
    • /
    • 2013
  • Wall thinning of pipeline in power plants occurs mainly by flow acceleration corrosion (FAC), cavitation erosion (C/E), liquid droplet impingement erosion (LDIE). Wall thinning by FAC and C/E has been well investigated; however, LDIE in plant industries has rarely been studied due to the experimental difficulty of setting up a long injection of highly-pressurized air. In this study, we designed a long-term experimental system for LDIE and investigate the behavior of LDIE for three kinds of materials (A106B, SS400, A6061). The main control parameter was the air-water ratio (${\alpha}$), which was defined as the volumetric ratio of water to air (0.79, 1.00, 1.72). In order to clearly understand LDIE, the spraying velocity (${\nu}$) of liquid droplets was controled larger then 160 m/s and the experiments were performed for 15 days. Therefore, this research focuses relation between erosion rate and air-water ratio on the various pipe-flow materials. NPP(nuclear power plant)'s LDIE prediction theory and management technique were drawn from the obtained data.

실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구 (Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor)

  • 동종인;구우회;임대현
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

고온 강판의 분무냉각에 있어서 MHF 점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.175-180
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about $900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the experimental results show that the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

고온 평판의 분무냉각에 있어서 MHF점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF