• Title/Summary/Keyword: Drop-tube furnace

Search Result 43, Processing Time 0.046 seconds

Study on the In-Furnace Desulfurization for Oxy-Fuel Combustion Flue Gases Using Drop Tube Furnace (Drop Tube Furnace를 이용한 순산소연소 배가스 로내탈황에 관한 연구)

  • An, Young-Mo;Jo, Hang-Dae;Choi, Won-kil;Park, Yeong-Sung;Keel, Sang-In;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.512-517
    • /
    • 2009
  • $SO_2$ concentrations in oxy-fuel combustion flue gases increases about three times as high as that of conventional air combustion system owing to the flue gas recirculation for the control of combustion temperature. So the desulfurization reaction is different from that of the conventional air combustion system due to exceptionally high $CO_2$ and $SO_2$ concentration. In this study, drop tube furnace(DTF) system was used to investigate the desulfurization characteristics of limestone in oxy-fuel combustion furnace. The experiments were performed under $O_2/CO_2$ atmosphere to examine the effect of operating variables such as reaction temperatures, Ca/S ratios and inlet $SO_2$ concentrations on the $SO_2$ removal efficiencies. $SO_2$ removal efficiency increased with reaction temperature, Ca/S ratio and inlet $SO_2$ concentration. And the addition of water vapor resulted in about 4~6% of increase in $SO_2$ removal efficiency.

Effect of Limestone Characteristics on In-Furnace Desulfurization under Hot Gas Combustion (석회석 분말을 이용한 노내 고온 건식 탈황 특성 연구)

  • Kim, Sang-in;Lee, Byung-hwa;An, Ke-ju;Hwang, Min-young;Kim, Seung-mo;Jeon, Chung-hwan
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.43-45
    • /
    • 2012
  • The effect of limestone characteristics on in-furnace desulfurization was experimentally investigated at hot gas combustion condition in a drop tube furnace (DTF). Flue gas was measured by Gas analyzer in order to figure out $SO_2$ content. The experiments were performed under excess sulfur 3000ppm condition to examine the effect of operating variables such as reaction temperatures, Ca/S ratios on the $SO_2$ removal efficiencies. The results show that the $SO_2$ removal efficiency increased with reaction temperature and Ca/S ratio increase. When considering the economics, $1200^{\circ}C$ and Ca/S ratio 2 condition is optimized to reduce $SO_2$ emission.

  • PDF

Pressurized Drop Tube Furnace Tests of Global Gasification Characteristics of Coal (PDTF를 이용한 석탄가스화 특성 실험)

  • 신용승;최상민;안달홍
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.560-566
    • /
    • 1999
  • PDTF (Pressurized drop tube furnace) experiments using variations of temperature, oxygen/coal ratio, steam/coal and pressure with Roto coal (Sub A) were performed in order to investigate the effects of these experimental parameters on global gasification characteristics at elevated pressure. The results shows that the gasification at elevated pressure is more profitable than that at atmospheric pressure considering the carbon conversion and cold gas efficiency. The oxygen/coal ratio at which maximum cold gas efficiency was appeared ranged from 0.5 to 0.7 g/g. only when the temperature is sufficiently high enough, the raise of steam/coal ratio brings improvement of cold gas efficiency. As the pressure increased, the volume of carbon conversion by heterogeneous reaction increased but the volume of carbon conversion by pyrolysis decreased relatively.

  • PDF

Pressurized drop tube furnace tests of global gasification characteristics of coal (PDTF를 이용한 석탄가스화 특성 실험)

  • 신용승;최상민;안달홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.23-31
    • /
    • 1999
  • PDTF(Pressurized drop tube furnace) experiments using varied temperature, oxygen/coal ratio, steam/coal ratio and pressure with Roto coal(Sub A) were performed in order to investigate the effects of these experimental parameters on global gasification characteristics at elevated pressure. The results shows that the gasification at elevated pressure is more profitable than that at atmospheric pressure considering the carbon conversion and cold gas efficiency. The oxygen/coal ratio at which maximum cold gas efficiency was appeared ranged from 0.5 to 0.7g/g. Only when the temperature is sufficiently high enough, the raise of steam/coal ratio brings improvement of cold gas efficiency. As the pressure increased, the volume of carbon conversion by heterogeneous reaction increased but the volume of carbon conversion by pyrolysis decreased relatively.

  • PDF

A Experimental Study of Oxidation Kinetics for a Sub-Bituminous Coal Char (아 역청탄 촤 산화 반응속도론에 관한 실험적 연구)

  • Kang, Ki-Tae;Song, Ju-Hun;Lee, Chuen-Sueng;Chang, Young-June;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.18 no.4
    • /
    • pp.239-246
    • /
    • 2009
  • A fundamental investigation has been conducted on the combustion of single particle of a sub-bituminous coal char burning at different temperatures and residence times. The lab-scale test setup consisted of a drop tube furnace where gas temperatures varied from $900^{\circ}C$ to $1400^{\circ}C$. A calibrated two color pyrometer, mounted on the top of the furnace, provided temperature profiles of luminous particle during a char oxidation. An amount of char mass reacted during the reaction is measured with thermogravimetry analyzer by using an ash tracer method. As a result, mass and area reactivity as well as reaction rate coefficients are determined for the char burning at atmospheric pressure condition.