• Title/Summary/Keyword: Drop-In

Search Result 6,203, Processing Time 0.037 seconds

Drop/Impact Simulation and Experimental Verification of a Reciprocating Compressor Body (왕복동형 압축기의 낙하충격 시뮬레이션 및 실험적 검증)

  • Kim, Tae-Jong;Kim, Moon-Saeng;Koo, Ja-Ham
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.484-490
    • /
    • 2007
  • A reciprocating compressor used in domestic refrigerators can be subjected to many different forms of shock. These shocks are usually experienced during transporting the products from a manufacturer to customers. The hermetic structure of this kind of compressor makes it difficult to conduct drop tests for identifying the failure mechanism and their drop behaviors. The drop/impact simulation for a reciprocating compressor has been carried out with the explicit code LS-DYNA and its validation has been experimentally verified. Simulation results are in good agreement with those of drop test. The present method of drop/impact simulation provides an efficient and powerful solution to improve the design quality and reduce the design period.

Test and Analysis of Voltage Drop according to Load Capacity in Traction Power Supply System (전기철도 일형식 부하 크기에 따른 전압강하 측정 및 분석)

  • Kim, Joo-Rak;Jang, Dong-Uk;Chang, Sang-Hoon;Lee, Young-Heum
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.940-947
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

Measurement and Analysis of Voltage Drop in Traction Power Supply System (전기철도 급전시스템의 안정화를 위한 전압강하 측정 결과 분석)

  • Kim, Joo-Rak;Lee, Young-Heum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2210-2211
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

Dynamic Jop Distribution Algorithm for Reducing Deadlock & Packet Drop Rate in NoC (NoC 시스템에서 Deadlock과 패킷 drop율 감소를 위한 동적 Job Distribution 알고리듬에 관한 연구)

  • Kim, Woo-Joo;Lee, Sung-Hee;Hwang, Sun-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7B
    • /
    • pp.528-537
    • /
    • 2008
  • This paper proposes a dynamic job distribution algorithm in a hybrid NoC structure which can improve system network performance by reducing deadlock and packet drop rate for various multimedia applications. The proposed job distribution algorithm schedules every job to the sub-cluster where packet drop rate can be minimized for each multimedia application program. The proposed Job distribution algorithm and network topology targets multimedia applications frequently used in modern embedded systems, such as MPEG4 and MP3 decoder, GPS positioning system, and OFDM demodulator. Experimental results show that packet drop rate was reduced by about 13.0%, and chip area was increased by about 2.7% compared to the APSRA algorithm. When compared to the XY algorithm popularly used for benchmarking, the packet drop rate was reduced by about 23.9%, while chip area was increased by about 3.0%.

Drop Performance Test of Control Rod Assembly for Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR 제어봉집합체 낙하성능시험)

  • Lee, Young Kyu;Kim, Hoe Woong;Lee, Jae Han;Koo, Gyeong Hoi;Kim, Jong Bum;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.134-140
    • /
    • 2016
  • The Control Rod Assembly (CRA) controls the reactor power by adjusting its position in the reactor core during normal operation and should be quickly inserted into the reactor core by free drop under scram condition to shut down chain reactions. Therefore, the drop time of the CRA is one of important factors for the safety of the nuclear reactor and must be experimentally verified. This study presents the drop performance test of the CRA which has been conceptually designed for the Proto-type Generation IV Sodium-cooled Fast Reactor. During the test, the CRA was free dropped from a height of 1 m under different flow rate conditions and its drop time was measured. The results showed that the drop time of the CRA increased as the flow rate increased; the average drop times of the CRA were approximately 1.527 seconds, 1.599 seconds and 1.676 seconds at 0%, 100% and 200% of design flow rates, respectively.

Drop and Damping Characteristics of the CEDM for the Integral Reactor (일체형원자로 제어봉구동장치의 낙하 및 완충특성)

  • Choi, M.H.;Kim, J.H.;Huh, H.;Yu, J.Y.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.7
    • /
    • pp.658-664
    • /
    • 2010
  • A control element drive mechanism(CEDM) is a reactor regulating system, which inserts, withdraws or maintains a control rod containing a neutron absorbing material within a reactor core to control the reactivity of the core. The ball-screw type CEDM for the integral reactor has a spring-damper system to reduce the impact force due to the scram of the CEDM. This paper describes the experimental results to obtain the drop and damping characteristics of the CEDM. The drop tests are performed by using a drop test rig and a facility. A drop time and a displacement after an impact are measured using a LVDT. The influences of the rod weight, the drop height and the flow area of hydraulic damper on the drop and damping behavior are also estimated on the basis of test results. The drop time of the control element is within 4.5s to meet the design requirement, and the maximum displacement is measured as 15.6 mm. It is also found that the damping system using a spring-hydraulic damper plays a good damper role in the CEDM.

NUMERICAL ANALYSIS ON PRESSURE DROP IN EXPANDED BED ACCORDING TO TUBE-TO-PARTICLE RATIOS AND REYNOLDS NUMBERS (Expanded bed에서 레이놀즈수와 직경입자비에 따른 압력강하 특성에 관한 수치적 연구)

  • Bae, S.W.;Sung, H.G.;Roh, T.S.
    • Journal of computational fluids engineering
    • /
    • v.16 no.2
    • /
    • pp.62-65
    • /
    • 2011
  • Characteristics of the pressure drop in an expanded bed have been compared to those in a packed bed for numerical study of the interphase drag in gas-particle flows. A numerical analysis of the pressure drop by the particle drag has been conducted according to the tube-to-particle diameter ratios and Reynolds numbers for comparison. As the tube-to-particle diameter ratios increase at the same Reynolds number, the pressure drop tends to converge. It has been confirmed that characteristics of the pressure drop in the expanded bed are similar to those in the packed bed.

Analysis of Metal Transfer using Dynamic Force Balance Model in GMAW (동적 힘 평형 모델을 이용한 GMA 용접의 용적이행 해석)

  • 최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.399-405
    • /
    • 2001
  • A dynamic force balance model is proposed in this work as an extension of the previous static force balance model to predict metal transfer in arc welding. Dynamics of a pendant drop is modeled as the second order system, which consists of the mass, spring and damper. The spring constant of a spherical drop at equilibrium is derived in the closed-form equation, and the inertia force caused by drop vibration is included in the drop detaching condition. While the inertia force is small in the low current range, it becomes larger than the gravitational force with current increase. The inertia force reaches half of the electromagnetic force at transition current, and has considerable effects on drop detachment. The proposed dynamic force balance model predicts the detaching drop size more accurately than the static force balance model.

  • PDF

Flow Pattern and Pressure Drop of Pure Refrigerants and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2289-2295
    • /
    • 2005
  • Two-Phase flow pattern and pressure drop data were obtained for pure refrigerants R134a and R123 and their mixtures as test fluids in a horizontal tube. The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section. The flow map of Baker developed for air-water two-phase flow at atmospheric pressure failed to predict the observed flow patterns at the higher value of the mass velocity used in the present study. The map of Kattan et al. predicted the data well over the entire region of mass velocity selected in the present study. The measured pressure drop increased with an increase in vapor quality and mass velocity. A new two-phase multiplier was developed from a dimensional analysis of the frictional pressure drop data measured in the present experiment. This new multiplier was found successfully to correlate the frictional pressure drop.

Robust Placement Method for IR Drop in Power Gating Design (파워 게이팅 설계에서 IR Drop에 견고한 셀 배치 방법)

  • Kwon, Seok Il;Han, Tae Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.55-66
    • /
    • 2016
  • Power gating is one of effective techniques for reducing leakage current in semiconductor chip. However, power gating cell (PGC) which is used to switch the power source causes performance degradation and the associated reliability problem by increasing IR drop. However, the newly raised problem caused by different scaling properties between gates and metal wires demands additional considerations in power gating design. In this paper, we propose a robust cell placement based power gating design method for reducing the area for power gating cell and metal routing thus to meet IR drop requirement. Experimental results by applying the proposed techniques on the application processor for smartphone fabricated in 28nm CMOS process show that power gating cell area is reduced by 16.16% and maximum IR drop value is also decreased by 8.49% compared to existing power gating cell placement techniques.