• 제목/요약/키워드: Drop-In

검색결과 6,203건 처리시간 0.032초

입자층 에어로졸여과의 과도거동에 관한 실험연구 : 압력강하에 대한 입자 퇴적의 영향 (An Experimental Study on Transient Behavior of Granular Aerosol Filtration : Effect of Particle Deposition on Pressure Drop)

  • 정용원
    • 한국대기환경학회지
    • /
    • 제13권3호
    • /
    • pp.193-205
    • /
    • 1997
  • Experiments on granular filtration of polydispersed aerosols were conducted to determine the changes in pressure drop necessary to maintain a given gas flow rate as filter becomes clogged with deposited particles. Among the various variables which affect the increase in the pressure drop during the filtration, the most important one was found to be the size of the deposited aerosol particles. It was shown that for a given extent of the total deposition, the extent of increase in pressure drop increases with the decrease of the deposited aerosol size. For the general case where the deposited particles have different sizes, a procedure was proposed for correlating and predicting experimental results on pressure drop. This procedure was found applicable to bidispersed aerosols and polydispersed aerosols.

  • PDF

파장 가변 가능한 광섬유 drop/pass필터의 특성 분석 (Characteristics of a tunable optical fiber drop/pass filter)

  • 박광로;조상연;이영탁;이경식;원용협
    • 전자공학회논문지S
    • /
    • 제34S권8호
    • /
    • pp.20-26
    • /
    • 1997
  • In this paper, we propose a tunable drop/pass filter in the form of composed of Mach-Zehnder interferometer, to which a fiber grating and two PZTs are attached. The proposed drop/pass filter drops a part of signal power at a specific wavelength and pass the remnant of the signal to the next node in WDM network. Our simulation results show that the optical feedback is less than 2% and the drop to pass ratio can be made bigger than 10% if the phase difference between the two arms is within .+-.0.2.pi. from (2m+1).pi.. Also, the output powers at drop prot and pass port are measured to be maximum at the phase difference of .pi./2 and .pi., respectively, as expected.

  • PDF

Drop Performance Test of Conceptually Designed Control Rod Assembly for Prototype Generation IV Sodium-Cooled Fast Reactor

  • Lee, Young-Kyu;Lee, Jae-Han;Kim, Hoe-Woong;Kim, Sung-Kyun;Kim, Jong-Bum
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.855-864
    • /
    • 2017
  • The control rod assembly controls reactor power by adjusting its position during normal operation and shuts down chain reactions by its free drop under scram conditions. Therefore, the drop performance of the control rod assembly is important for the safety of a nuclear reactor. In this study, the drop performance of the conceptually designed control rod assembly for the prototype generation IV sodium-cooled fast reactor that is being developed at the Korea Atomic Energy Research Institute as a next-generation nuclear reactor was experimentally investigated. For the performance test, the test facility and test procedure were established first, and several free drop performance tests of the control rod assembly under different flow rate conditions were then carried out. Moreover, performance tests under several types and magnitudes of seismic loading conditions were also conducted to investigate the effects of seismic loading on the drop performance of the control rod assembly. The drop time of the conceptually designed control rod assembly for 0% of the tentatively designed flow rate was measured to be 1.527 seconds, and this agrees well with the analytically calculated drop time. It was also observed that the effect of seismic loading on the drop time was not significant.

Sn-3.0Ag-0.5Cu 및 Sn-1.0Ag-0.5Cu 조성의 솔더 볼을 갖는 플립칩에서의 보드레벨 낙하 해석 (Board-Level Drop Analyses having the Flip Chips with Solder balls of Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.5Cu)

  • 김성걸
    • 한국생산제조학회지
    • /
    • 제20권2호
    • /
    • pp.193-201
    • /
    • 2011
  • Recently, mechanical reliabilities including a drop test have been a hot issue. In this paper, solder balls with new components which are Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.5Cu-0.05N are introduced, and board level drop test for them are conducted under JEDEC standard in which the board with 15 flip chips is dropped as 1,500g acceleration during 0.5ms. The drop simulations are studied by using a implicit method in the ANSYS LS-DYNA, and modal analysis is made. Through both analyses, the solder balls with new components are evaluated under the drop. It is found that the maximum stress of each chip is occurred between the solder ball and the PCB, and the highest value among the maximum stresses in the chips is occurred on the chip nearest to fixed holes on the board in the drop tests and simulations.

판형열교환기의 열전달특성 및 압력강하에 관한 해석적 연구 (Numerical Analysis on Heat Transfer Characteristics and Pressure Drop in Plate Heat Exchanger)

  • 김광률;김일겸;임장순
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.19-26
    • /
    • 2002
  • This study aims at numerically analyzing on heat transfer the characteristics and pressure drop of plate heat exchanger(PHE) using the Phoenics 3.1 VR Editor for the standard k-$\varepsilon$ model. Computations have been carried out for a range of chevron angle from $30^{\circ}$ to $60^{\circ}$, inlet velocity from 0.03m/s to 0.63m/s and the height of corrugation from 0.0045m to 0.0060m. The results show that both of heat transfer performance and pressure drop increase as chevron angle increases. This is because higher troughs produce higher turbulence and a higher heat transfer coefficient in the liquids flowing between the plates. As inlet velocity from 0.03m/s to 0.63m/s increases, heat transfer performance and pressure drop increase parabolically. As the height of corrugation increases, both of heat transfer performance and pressure drop decrease with the decrease of velocity. And the pressure drop decreases and the friction factor increases as the height of corrugation increases.

원예시설용 망의 압력강하 특성에 대한 실험적 연구 (An Experimental Study on Characteristics of Pressure Drop of Screens Used in Horticultural Facilities)

  • 염성현;강승희
    • 한국농공학회논문집
    • /
    • 제55권6호
    • /
    • pp.31-35
    • /
    • 2013
  • This study was carried out to present the pressure drop for various wind speeds through nine types of screens used in horticultural facilities. The screens have been widely used to prevent harmful insects from being entered into agricultural facilities, to reduce strong wind and to shade a light as well. Whatever the usage of the screens was, it was necessary to have good knowledge of how much the screen caused a pressure drop for wind speeds when analyzing both the inner thermal-flow distribution in the facility and the effect of reducing wind speed by using CFD. Furthermore, as for wind screens, the pressure drop for wind speeds was needed as a design load in evaluating the structural stability of the structures supporting the screens. Therefore, the pressure drop through the screens for wind speeds of 5~30 $m{\cdot}s^{-1}$ at about 5 $m{\cdot}s^{-1}$ interval and inflow angles of $0{\sim}45^{\circ}$ at an interval of $15^{\circ}$ was respectively measured in a subsonic wind tunnel. The relation of the pressure drop for various screens was well fitted as a secondorder polynomial expression.

뇌졸중 환자의 장애물 보행능력 향상과 하수족 개선을 위한 고유수용성신경근촉진법의 적용: 증례보고 (Approach of Proprioceptive Neuromuscular Facilitation on Foot drop and Crossing Obstacles in stroke patient: Case report)

  • 송귀빈
    • PNF and Movement
    • /
    • 제13권2호
    • /
    • pp.111-118
    • /
    • 2015
  • Purpose: The purpose of this study was to describe the effects of proprioceptive neuromuscular facilitation (PNF) on episodes of foot drop and the ability to cross obstacles in stoke patients. Methods: The patient was a 57-year-old man with left hemiplegia. This patient displayed episodes of foot drop while walking and issues with crossing obstacles. The patient underwent therapeutic exercises and occupational therapy twice daily at a hospital five times a week. The patient was treated with PNF outside of these therapeutic sessions. Each session, which was 60 minutes in length, was conducted 3 times a week over 8 weeks. Over the course of treatment, a pre-test and post-test were completed. The patient walked for a test time of 6M. During the testing process, the patient crossed obstacles. In addition, the number of foot drop episodes was recorded. Each test was measured three times to determine the mean value. Results: After the PNF treatments, the number of foot drop episodes decreased from five to one. The 6M walking test time during which the patient crossed obstacles also decreased from 18 seconds to 10 seconds. Conclusion: The use of PNF treatments is beneficial to reduce the number of foot drop episodes while walking and to improve the ability to cross obstacles in stroke patients.

주름관에서의 압력강하와 마찰손실 계측에 관한 연구 (The study on the measurement for the pressure drop and friction factor of corrugated metal pipes)

  • 윤영선;강준원;유재석;김현정
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.76-80
    • /
    • 2006
  • The data for friction factor of the pipe correlated by Reynolds number and relative roughness have been reported well as a Moody chart. However, the results for corrugated shapes have been not investigated sufficiently. In this research, therefore, the pressure drop and friction factor are obtained. Flexible metal tubes with corrugations for the measurement are made of stainless steel plates. The kinds of tubes for the measurement are 5 annular types and helical types. The pressure drop & the velocity of the flow are obtained by micromanometer & digital pressure sensor, supplying dry air at several steps. Then the pressure drop is calculated for each tube, using the obtained data. The result shows that the pressure drop is strongly influenced by the viscous dissipation of kinetic energy due to the circulation of flows, rather than a viscous friction loss. The pressure drop increased consistently as the Reynolds number increases.

  • PDF

액주형 이류체노즐의 반경반향 분무특성에 관한 연구 (A Study on the Radial Spray Performance of a Plaint-Jet Twin-Fluid Nozzle)

  • 최진철;노병준;강신재
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.662-669
    • /
    • 1994
  • In the combustion system, the optimum spray conditions reduce the pollutant emission of exhaust gas and enhance the fuel efficiency. The spray characteristics-the drop size, the drop velocity, the number density and the mass flux, become increasingly important in the design of combustor and in testifying numerical simulation of spray flow in the combustor. The purposes of this study are to clarify the spray characteristics of twin-fluid nozzle and to offer the data for combustor design and the numerical simulation of a spray flow. Spatial drop diameter was measured by immersion sampling method. The mean diameter, size distribution and uniformity of drop were analyzed with variations of air/liquid mass flow ratio. The results show that the SMD increases with the liquid supply flow rate and decreases with the air supply velocity. The radial distribution of SMD shows the larger drops can diffuse farther to the boundary of spray. And the drop size range is found to be wider close to the spray boundary where the maximum SMD locates.

낙하해석을 통한 보드 레벨 플립칩에서의 솔더볼 충격수명에 관한 연구 (Prediction of Impact Life Time in Solder Balls of the Board Level Flip Chips by Drop Simulations)

  • 장총민;김성걸
    • 한국생산제조학회지
    • /
    • 제23권3호
    • /
    • pp.237-242
    • /
    • 2014
  • Recently much research are has been done into the compositions of lead-free solders. As a result, there has been a rapid increase in the number of new compositions. In the past, the properties of these new compositions were determined and verified through drop-impact tests. However, these drop tests were expensive and it took a long time to obtain a result. The main goal of this study was to establish an analytical method capable of predicting the impact life-time of a new solder composition for board-level flip chips though the application of drop simulations using LS-DYNA. Based on the reaction load obtain with LS-DYNA, the drop-impact fracture cycles were predicted. The study was performed using a Sn-3.0Ag-0.5Cu solder (305 composition). To verify the reliability of the proposed analytical method, the results of the drop-impact tests and life-time analysis were compared, and were found to be in good agreement. Thus, the new analytical method was shown to be very useful and effective.