• Title/Summary/Keyword: Drop structure

Search Result 553, Processing Time 0.027 seconds

Study on Crashworthiness of Icebreaker Steel: Part II Ship Side Structural Behavior Due to Impact Bending (쇄빙선의 내충격 특성에 관한 실험적 연구: 제2부 선체 구조의 충격 굽힘 특성)

  • Noh, Myung-Hyun;Lee, Jae-Yik;Han, Donghwa;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.277-286
    • /
    • 2016
  • The first part of this study found the tendencies of the mechanical properties of two arctic structural steels (EH32 and FH32). In the second part, the crashworthiness of stiffened panels scaled down from the side frame structure of a Korean research icebreaker was determined. A procedure for designing the shapes and sizes of the stiffened panels, mass and shape of a drop striker, and a large temperature chamber, and then manufacturing these, is introduced in detail. From impact bending tests for the stiffened panels, the residual permanent deformations and deformation histories over time were captured using manual measurement and video image analyses. Numerical simulations of the impact bending tests were carried out for three different finite element models, which were mainly composed of shell elements, solid elements, and solid elements, with welding beads. It was proven from a comparison of the test results and numerical simulation results that the solid element model with the welding bead consideration approached the test results in terms of the residual deformations as long as the strain rate effect was taken into account.

Numerical Modeling of Wave-Type Flow on a Stepped Weir (계산형 위어에서의 파형흐름 수치모의)

  • Paik, Joongcheol;Kang, Joon Gu;Lee, Nam-Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.65-65
    • /
    • 2016
  • Various types of flow conditions are developed in the region just downstream of hydraulic structures such as weir and drop structures. One of distinct flow conditions occurred downstream of drop structures is the wave type flow with undular hydraulic jump formation. We present three-dimensional numerical simulations of a wave type flow formed downstream of a stepped weir which were experimentally investigated by Kang et al. (2010). The turbulent flow over the weir structure is modeling using the unsteady Reynolds-averaged Navier-Stokes (URANS) simulation employing the Spalart-Allmaras one equation model and the detached eddy simulation. Numerical modeling and the performance of turbulence modeling approaches are evaluated by comparing with the experimental measurements in terms of the free surface variation, the shapes and sizes of undular wave, roller near at free surface, recirculation zone near the channel bottom downstream of the structures, and streamwise velocity profiles at selected longitudinal locations.

  • PDF

Comparison of Loss Coefficient using 1-inch Ball and Glove Valve Opening Ratio (1인치 볼 밸브 및 글로브 밸브에 대한 개도율에 따른 손실계수(k) 비교에 관한 연구)

  • Kang, Chang-Won;Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.63-69
    • /
    • 2021
  • This study aims to determine the flow characteristics of a one-inch small ball valve and glove valve used in industrial plants. The flow was changed through an experimental equipment, and the internal flow characteristics of the valves were compared. Considering the pressure drop, the decrease in the slope of the ball valve based on the degree of the valve opening was relatively greater than that of the glove valve; further, the slope of the glove valve was gentle while the pressure drop was high. The flow velocity of the ball valve remains consistent after the valve was opened by 70%, whereas the flow velocity of the glove valve constantly increased. The valve loss factor of the ball valve was relatively low compared with that of the glove valve. When the valve was opened by 20%, which is the beginning stage of the valve opening, the valve loss factor of the ball valve was high and gradually became low. This is a structural problem of the ball valve, and the loss factor is significant because the flow path installed at the ball valve has a considerably small area. However, the overall loss factor of glove valve is high because it has a complicated structure of flow path.

A Study on the Electrical Characteristics according to Growth of Trench SiO2 Inside Super Junction IGBT Pillar (Super Junction IGBT 필러 내부 Trench SiO2성장에 따른 전기적 특성에 관한 연구)

  • Lee, Geon Hee;Ahn, Byoung Sup;Kang, Ey Goo
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.344-349
    • /
    • 2021
  • This paper proposes a structure in which Trench SiO2 is grown inside of Super Junction IGBT P-Pillar. When observing the electric field in 3D, we checked the region where the electric field have not affected inside of the P-Pillar. The pillar region's portion resistance is varied by the breakdown voltage and size of each pillar, which reduces the size by growing SiO2 after trenching has no field effect inside of that. At 4.5kV the same breakdown voltage, it was confirmed that the On-state voltage drop improved by about 58%, 19% compared to Field Stop IGBT and conventional Super Junction IGBT.

Investigation of Optimum Condition of Heat Treatment and Flow to Improve H2S Adsorption Capacity for Practical use of an Activated Carbon Tower (활성탄 흡착탑의 실용화를 위한 최적 유동특성 선정 및 열처리 조건에 따른 황화수소 포집능 향상 연구)

  • Jang, Younghee;Kim, Bong-Hwan;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.91-96
    • /
    • 2021
  • This study was conducted to improve the operating conditions of an adsorption tower filled with potassium impregnated activated carbon for high hydrogen sulfide capture capacity. Heat treatment modified the surface properties of activated carbon, and ultimately determined its adsorption capacity. The activated carbon doped with potassium showed 57 times more adsorption at room temperature than that of using the raw adsorbent. It is believed that uniform pore formation and strong bonding of the potassium on the surface of carbon contributed to the chemical and physical absorption of hydrogen sulfide. The SEM analysis on the surface structure of various commercial carbons showed that the modification of surface properties through the heat treatment generated the destruction of pore structures resulted in the decrease of the absorption performance. The pressure drop across the activated carbon bed was closely related with the grain size and shape. The optimum size of irregularly shaped activated carbon granules was 2~4 mesh indicating economical feasibility.

Numerical Investigation of the Progressive Failure Behavior of the Composite Dovetail Specimens under a Tensile Load (인장하중을 받는 복합재료 도브테일 요소의 점진적인 파손해석)

  • Park, Shin-Mu;Noh, Hong-Kyun;Lim, Jae Hyuk;Choi, Yun-Hyuk
    • Composites Research
    • /
    • v.34 no.6
    • /
    • pp.337-344
    • /
    • 2021
  • In this study, the progressive failure behavior of the composite fan blade dovetail element under tensile loading is numerically investigated through finite element(FE) simulation. The accuracy of prediction by FE simulation is verified through tensile testing. The dovetail element is one of the joints for coupling the fan blade with the disk in a turbofan engine. The dovetail element is usually made of a metal material such as titanium, but the application of composite material is being studied for weight reduction reasons. However, manufacturing defects such as drop-off ply and resin pocket inevitably occur in realizing complex shapes of the fan blade made by composite materials. To investigate the effect of these manufacturing defects on the composite fan blade dovetail element, we performed numerical simulation with FE model to compare the prediction of the FE model and the tensile test results. At this time, the cohesive zone model is used to simulate the delamination behavior. Finally, we found that FE simulation results agree with test results when considering thermal residual stress and through-thickness compression enhancement effect.

Effect of excitation type on dynamic system parameters of a reinforced concrete bridge

  • Wahab, M.M. Abdel;De Roeck, G.
    • Structural Engineering and Mechanics
    • /
    • v.7 no.4
    • /
    • pp.387-400
    • /
    • 1999
  • Damage detection in civil engineering structures using the change in dynamic system parameters has gained a lot of scientific interest during the last decade. By repeating a dynamic test on a structure after a certain time of use, the change in modal parameters can be used to quantify and qualify damages. To be able to use the modal parameters confidentially for damage evaluation, the effect of other parameters such as excitation type, ambient conditions,... should be considered. In this paper, the influence of excitation type on the dynamic system parameters of a highway prestressed concrete bridge is investigated. The bridge, B13, lies between the villages Vilvoorde and Melsbroek and crosses the highway E19 between Brussels and Antwerpen in Belgium. A drop weight and ambient vibration are used to excite the bridge and the response at selected points is recorded. A finite element model is constructed to support and verify the dynamic measurements. It is found that the difference between the natural frequencies measured using impact weight and ambient vibration is in general less than 1%.

Measurement of Fluid Dynamic Characteristics around Stenotic Obstruction in a Circular Channel

  • An, Jin-Hyo;Cheema, T.A.;Jeong, Seong-Ryong;Lee, Choon-Young;Kim, Gyu-Man;Park, Cheol-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.7
    • /
    • pp.921-929
    • /
    • 2011
  • We measured experimentally the properties of fluid dynamics, velocity fields, and the pressure, around stenotic obstruction located inside a circular channel structure. Particle image velocimetry system was employed to obtain velocity fields at the central section of the circular channel in the streamwise direction. The stenosis model used was made of acrylic material with different stenotic aspect ratios. The working fluid was water and it was returned by a centrifugal pump system. Pressure measurements were carried out to validate the effect of a narrow passageway. Results showed that the acceleration of gap flow through stenotic obstruction and the pressure drop in the recirculation regime behind the stenosis model can be observed.

An Implementation on the High Speed Blowfish

  • Park, Jong-Tae;Rhee, Kang-Hyeon
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.635-638
    • /
    • 2002
  • Blowfish is a symmetric block cipher that can be used as a drop-in replacement fur DES or IDEA. It takes a variable-length key, from 32bit to 448bit, making it ideal for both domestic and exportable use. This paper is somewhere middle-of-the-line, where this paper made significant tradeoffs between speed, size and ease of implementation. The main focus was to make an implementation that was usable, moderately compact, and would still run at an acceptable clock speed. For the real time process of blowfish, it is required that high-speed operation and small size hardware. So, A structure of new adders constructed in this study has all advantages abstracted from other adders. As for this new adder, area cost increases by 1.06 times and operation speed increases by 1.42 times.

  • PDF

The Study of Purification and Crystallyzation from Etrlene induced Chitinase (강낭콩잎에 Ethylene을 처리하여 유도한 Chitinase의 분리정제와 결정화에 관한 연구)

  • 홍순강
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.126-131
    • /
    • 1995
  • Chitinase, a potential pathogensis- related portein, was induced in the leaves of 30 day - old bean( phaseolus vulgaris ) plant with the treatment of 10 $\mu $ /mℓ ethylen for 30hrs. Chitinase was purified from the mature tissue of bean leaves( phaseolus vulgaris ) by ammonium sulfate precipitation followed by affinity chromatography on a regenerated chitin and sephadex G-75 chromatography. The purified chitinase gave a single band SDS- PAGE to be 32,000 Dalton. In order to elucidate the three- dimensional structure of chitinase and to shed light on the functional mechanism of this class of enzymes, the enzyme was tried to crystallize( Sitting Drop Method). Crystals grew at room temperature to their final size within two weeks(0.2mm $\times $0.2mm $\times $ 0.1 mm ), This enzyme are still continuing to crystallize for the study of X- ray.

  • PDF