DOI QR코드

DOI QR Code

Measurement of Fluid Dynamic Characteristics around Stenotic Obstruction in a Circular Channel

  • An, Jin-Hyo (School of Mechanical Engineering, Kyungpook National University) ;
  • Cheema, T.A. (School of Mechanical Engineering, Kyungpook National University) ;
  • Jeong, Seong-Ryong (Refrigerator BU, LG Electronics Inc.) ;
  • Lee, Choon-Young (School of Mechanical Engineering, Kyungpook National University) ;
  • Kim, Gyu-Man (School of Mechanical Engineering, Kyungpook National University) ;
  • Park, Cheol-Woo (School of Mechanical Engineering, Kyungpook National University)
  • Received : 2011.11.14
  • Accepted : 2011.11.29
  • Published : 2011.11.30

Abstract

We measured experimentally the properties of fluid dynamics, velocity fields, and the pressure, around stenotic obstruction located inside a circular channel structure. Particle image velocimetry system was employed to obtain velocity fields at the central section of the circular channel in the streamwise direction. The stenosis model used was made of acrylic material with different stenotic aspect ratios. The working fluid was water and it was returned by a centrifugal pump system. Pressure measurements were carried out to validate the effect of a narrow passageway. Results showed that the acceleration of gap flow through stenotic obstruction and the pressure drop in the recirculation regime behind the stenosis model can be observed.

Keywords

References

  1. Siebes M., Verhoeff B. J., Meuwissen M., Winter R. J., Spaan J. A. E. and Piek J. J., "Single‐wire pressure and flow velocity measurement to quantify coronary stenosis hemodynamics and effects of percutaneous interventions", Circulation, vol. 109, pp. 756- 762, 2004. https://doi.org/10.1161/01.CIR.0000112571.06979.B2
  2. Marques K. M., Spruijt H. J., Boer C., Westerhof N., Visser C. A. and Visser F. C., "The diastolic flow‐pressure gradient relation in coronary stenoses in humans", Journal of the American College of Cardiology, vol. 39, no. 10, pp. 1630-1636, 2002. https://doi.org/10.1016/S0735-1097(02)01834-X
  3. Stroud J. S., Berger S. A. and Saloner D., "Numerical analysis of flow through a severely stenotic carotid artery bifurcation", Journal of Biomechanical Engineering, vol. 124, no. 9, pp. 9-20, 2002. https://doi.org/10.1115/1.1427042
  4. Garcia D., Kadem L., Savery D., Pibarot P. and Durand L. G., "Analytical modeling of the instantaneous maximal transvalvular pressure gradient in aortic stenosis", Journal of Biomechanics, vol. 39, no. 16, pp. 3036-3044, 2006. https://doi.org/10.1016/j.jbiomech.2005.10.013
  5. Mofrad M. R. K., S. Wada, Myers J. G. and Ethier C. R., "Blood flow and mass transfer in arteries with axisymmetric and asymmetric stenoses", International Journal of Heat and Mass Transfer, vol. 48. pp. 4510-4517, 2005. https://doi.org/10.1016/j.ijheatmasstransfer.2005.05.004
  6. Golpayeghani A. T., Najarian S. and Movahedi M.M., "Numerical simulation of pulsatile flow with Newtonian and non‐Newtonian behavior in arterial stenosis", Iranian Cardiovascular Research Journal, vol. 1, no. 3, pp. 167-174, 2008.
  7. Stroud J.S., Berger S.A. and Saloner D., "Influence of stenosis morphology on flow through severely stenotic vessels: implications for plaque rupture", Journal of Biomechanics, vol. 33, pp. 443-455, 2000. https://doi.org/10.1016/S0021-9290(99)00207-9
  8. Ahmed S. A. and Giddens D. P., "Velocity measurements in steady flow through axisymmetric stenoses at moderate Reynolds number", Journal of Biomechanics, vol. 16, pp. 505-516, 1983. https://doi.org/10.1016/0021-9290(83)90065-9
  9. Ojha M., Cobbold C., Johnston K. W. and Hummel R. L., "Pulsatile flow through constricted tubes: an experimental investigation using photochromic tracer methods", Journal of Fluid Mechanics, vol. 203, pp. 173-197, 1989. https://doi.org/10.1017/S0022112089001424
  10. Park C. W. and Lee S. J., "Effects of free‐end corner shape on flow structure around a finite cylinder", Journal of Fluids and Structures, vol. 19, no. 2, pp. 141-158, 2004. https://doi.org/10.1016/j.jfluidstructs.2003.12.001
  11. Meinhart C. D., Wereley S. T. and Santiago J. G., "PIV measurements of a microchannel flow", Experiments in Fluids, vol. 27, pp. 414-419, 1999. https://doi.org/10.1007/s003480050366
  12. Lima R. C., Andrade C. R. and Zaparoli E. L., " Numerical study of three recirculation zones in the unilateral sudden expansion flow", International Communications in Heat and Mass Transfer, vol. 35, pp. 1053-1060, 2008. https://doi.org/10.1016/j.icheatmasstransfer.2008.07.004
  13. Adams E. W. and Johnston J. P., "Effects of the separating shear‐layer on the reattachment flow structure part 2: reattachment length and wall shear‐stress", Experiments in Fluids, vol. 6, pp. 493-499, 1988. https://doi.org/10.1007/BF00196511
  14. Lee T. S., Liao W. and Low H. T., "Numerical simulation of turbulent flow through series stenoses", International Journal of Numerical Methods in Fluids, vol. 42, no. 7, pp. 717-740, 2003. https://doi.org/10.1002/fld.550
  15. Deshpande M. D. and Giddens D. P., "Turbulence measurements in a constricted tube", Journal of Fluid Mechanics, vol. 97, pp. 65-89, 1980. https://doi.org/10.1017/S0022112080002431