• 제목/요약/키워드: Drop pattern

검색결과 276건 처리시간 0.023초

Measurement of Sonobuoy Transmitting Antenna System for Anti-Submarine Warfare

  • Min Kyeong-Sik
    • Journal of electromagnetic engineering and science
    • /
    • 제5권2호
    • /
    • pp.97-103
    • /
    • 2005
  • This paper describes the measured results of sonobuoy transmitting antenna system for anti-submarine warfare (ASW). Since radiation pattern and power density depend on impedance matching between transmitting RF part and antenna with termination resistance, design of matching circuit is very important for sonobuoy system performance. Matching circuit is designed by Smith chart using control of L and C. In standing wave ratio(SWR) measurement using Network Analyzer, SWR of antenna with matching circuit observed 1.5 below at the assigned VHF band. It shows very excellent performance comparison with conversional product that is used for the same object. The measured vertical and horizontal radiation patterns are also shown the satisfaction of military specifications. A drop out of sonobuoy system on the sea is happened when angle of elevation direction is over 10 degrees, and it is conformed that it takes less than I second return to original signal level. The required electric power density is $83\;mW/m^2$ in the military specification, and measured electric power density is observed over average $110\;mW/m^2$ at all frequency bands.

소프트볼 투구 구질에 따른 압력중심 이동패턴의 차이점 분석 (Comparative study of CP(center of pressure) Pattern on pitching sort in Softball)

  • 문영진;김진경
    • 한국운동역학회지
    • /
    • 제16권3호
    • /
    • pp.183-188
    • /
    • 2006
  • This research is to know differentiation of CP(center of pressure) pattern among four pitching sort(straight ball, raise ball, change up ball, drop ball). Subject are three national or junior athletes. We use the one camera, Novel Win pressure measurement system. Conclusions are as follows : 1. When we throw the straight ball, CP of left foot is effective to end movement at middle of foot in body balance on arm angular motion and enhanced speed. 2. When we throw the raise ball, to change CP from middle to post is more effective in order to raise the ball. 3.In drop ball pitching, in order to fall down the ball in front of hitter, CP of left foot move from post foot to interior part of forefoot 4. In change up ball pitching, if CP of left foot move into forefoot, it is a cause of high ball and hitter can recognize the change up ball because of late arm rotation motion.

수직상향 기액이상류의 유동특성 (Flow Characteristics of Vertical Upward Gas-Liquid Two-Phase Flow)

  • 최부홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.377-383
    • /
    • 2005
  • This paper deals with the flow characteristics of air-water two-phase flow in a vertical tube of 10mm I.D. and 600mm in length at an adiabatic condition. The obtained experimental data were covered with the liquid superficial velocity ranging from 0.095m/s to 2.56m/s. and the gas superficial velocity ranging from 0.032m/s to 21.08m/s. The effects of the gas and liquid superficial velocity on the flow pattern transitions, frictional pressure drop, and film thickness and gas-liquid interface roughness were also examined. It was found that the film thickness increased and the liquid film wave length was more longer with the liquid superficial velocity $j_L$ increasing at $j_G$ constant. It was also showed that the frictional pressure drops were experienced in three regions. namely increasing region(bubbly flow), decreasing region (Taylor bubble and slug flows) and re-increasing region (annular flow).

수평 기액2상유동에서 유동양식의 천이특성 (Characteristics of Flow Regime Transitions in Horizontal Gas-Liquid Two-Phase Flow)

  • 이상천;이정표;김중엽
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.342-349
    • /
    • 1988
  • The characteristics of flow pattern transitions in a horizontal cocurrent gas-liquid flow have been investigated by means of a statistical analysis of instantaneous pressure drop curves at an orifice. The dimensionless intensity of pressure drop fluctuation shows a sudden change during the course of flow transitions, indicating that it may be a good measure to identify the flow regime transitions. The probability density function of the curves feature a unique pattern depending upon the flow regimes and the statistical properties of the PDF also have particular ranges for each flow regime. In conclusion, the statistical analysis of instantaneous pressure drops may be a powerful tool for predicting the flow regime transitions.

  • PDF

Numerical investigations on the effect of tortuosity on friction factor in superconducting CICC configuration

  • Vaghela, Hitensinh;Lakhera, Vikas;Bhatt, Kunal;Sarkar, Biswanath
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.49-55
    • /
    • 2021
  • The Cable in Conduit Conductor (CICC) configurations are designed, tested and realized to make high field superconducting (SC) magnets. The evolution of CICC design makes it challenging to forecast thermo-hydraulic behavior. A common objective of thermo-hydraulic studies is to obtain the most reliable predictive correlation for friction factor in CICC geometries and to reduce the dependency on the experiment. So far, only the void fraction and Reynolds number have been considered in the predictive correlations in an explicit way. In the present paper, the CICC twisting pattern dependency, called tortuosity (τ), on the pressure drop prediction, has been assessed through a numerical simulation approach. The CICC twisting pattern with 6+1 petals (solid conductor in the present study) with different twisting pitches is mimicked in the numerical simulation for the range 100 ≤ Re ≤10000 and 1 < τ < 1.08 and a correlation for friction factor, f, has been proposed as a function of Re and τ.

인터넷에서 Assured Forwarding 패킷을 위한 사이클링 패킷 폐기 메커니즘 (Cycling Packet Dropping Mechanism for Assured Forwarding Packets in Internet)

  • 김수연;강현국
    • 정보처리학회논문지C
    • /
    • 제9C권2호
    • /
    • pp.221-226
    • /
    • 2002
  • 본 논문에서 제안한 사이클링 패킷 폐기 메커니즘은 사이클 사이의 트래픽 변화를 예측하여 패킷 폐기를 적응적으로 처리할 수 있다. 따라서 제안된 메커니즘은 RIO 메커니즘의 단순 폐기율 적용에 대한 단점을 보완하고, 동적 엄격 패킷 폐기 메커니즘의 예측 가능한 오류율을 최소화하였다. 시뮬레이션을 수행하여, 망 트래픽의 상태에 따라 동적으로 변하는 전송가능 폐기순위에 따른 처리율과 패킷 폐기율을 분석하였다. 시뮬레이션을 분석한 결과 제안된 메커니즘은 트래픽의 양에 상관없이 각 AF 클래스의 폐기순위를 엄격하게 적용하고 폐기순위에 따른 패킷 전송능력이 개선하였음을 증명하였다.

Depth Jump 시 하지 관절 상해에 관한 운동역학적 분석 (The analysis of lower extremities injury on depth jump)

  • 소재무;김윤지;이종희;서진희;정연옥;김광기
    • 한국운동역학회지
    • /
    • 제15권1호
    • /
    • pp.127-142
    • /
    • 2005
  • The purpose of this study was to analysis biomechanics of the lower extremities injury the heights(40cm, 60cm, 80cm) of jump box as performed depth jump motion by 6 females aerobic athletes and 6 non-experience females students. The event of depth jump were set to be drop, landing and jump. The depth jump motions on the force plate were filmed using a digital video cameras, and data were collected through the cinematography and force plate. On the basis of the results analyzed, the conclusions were drawn as follows: 1. The landing time of skill group was shorter than unskill group at 40cm, 60cm drop height during drop-landing-jump phase especially. The landing time of 60cm drop height was significant between two group(p<.05). 2. The peak GRF of sagittal and frontaI direction following drop height improve was variety pattern and the peak vertical force of 40cm drop height was significantly(p<.05). 3. The magnitude of peak passive force was not increase to change the drop height. 4. The peak passive forces was significant at 40cm drop height between two groups(p<.05)

자연대류를 이용한 변압기용 방열기의 채널 구조가 방열성능에 미치는 영향 (EFFECT OF THE CHANNEL STRUCTURE ON THE COOLING PERFORMANCE OF RADIATOR FOR TRANSFORMER OF NATURAL CONVECTION TYPE)

  • 김다은;강상모;서용권
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.86-93
    • /
    • 2014
  • Increased demand of power-transformer's capacity inevitably results in an excessive temperature rise of transformer components, which in turn requires improved radiator design. In this paper, numerical simulation of the cooling performance of an ONAN-type (Oil Natural Air Natural) radiator surrounded by air was performed by using CFX. The natural convection of the air was treated with the full-model. The present parametric study considers variation of important variables that are expected to affect the cooling performance. We changed the pattern and cross-sectional area of flow passages, the fin interval, the flow rate of oil and shape of flow passages. Results show that the area of flow passage, the fin interval, the flow rate of oil and shape of flow passages considerably affect the cooling performance whereas the pattern of flow passages is not so much influential. We also found that for the case of the fin interval smaller than the basic design, the temperature drop decreases while a larger interval gives almost unchanged temperature drop, indicating that the basic design is optimal. Further, as the flow rate of oil increases, the temperature drop slowly decreases as expected. On the other hand, when the shape of flow passages are changed, temperature drop is increased, indicating that the cooling performance is enhanced thereupon.

판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가 (Experimental measurements of R-22 two-phase friction factor in plate heat exchangers)

  • 유상훈;정지환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF