• 제목/요약/키워드: Drop Out

검색결과 1,049건 처리시간 0.022초

Effect of Heat Shock on Culture Method and Essential Amino Acid Free Medium of IVM-Derived Bovine Embryo (체외성숙된 소 배에서 배양방법과 필수 아미노산 무첨가 배지에서의 온도충격의 영향)

  • 김지철;김재영;주재홍;윤산헌;이상민;이상진;김재명;송해범;박흠대
    • Journal of Embryo Transfer
    • /
    • 제16권1호
    • /
    • pp.41-46
    • /
    • 2001
  • This study was carried out to evaluate the effect of culture methods on development of embryos with each developmental stage after heat shock in bovine oocytes. The results obtained were as fellows. 1. The culture method after heat shock on development of embryos was better drop-culture than co-culture. 2. The medium without amino acids were not effect of heat sock on development of embryos but it was in need of amino acid during formation of blastocyst.

  • PDF

An Experimental Study on Condensation Characteristics at Various Condensation Pressure of R407C (응축압력 변화에 따른 R407C의 응축특성에 관한 연구)

  • 전창덕;장경근;김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제15권3호
    • /
    • pp.230-238
    • /
    • 2003
  • R407C is considered as alternative refrigerant of R22 for air conditioners. Experimental investigation is made to study the condensation heat transfer characteristics of slit fin-tube heat exchanger using alternative refrigerant, R407C. Experiments are carried out at condensation pressure of 2110 kPa and 1943 kPa with the degree of superheat of 1$0^{\circ}C$ and mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air condition is dry bulb temperature of 35$^{\circ}C$, relative humidity of 50% and air velocity varying from 0.8 to 1.6 m/s. Experiments show that pressure drop gets smaller at a higher condensation pressure especially when condensation pressure is raised from 1943 to 2110 kPa. Heat transfer rate gets smaller at a lower condensation pressure in the range of experimental condition.

The Effect of the Characteristics of Tipping Paper, Plug Wrap and Glue on the Cigarette Ventilation (팁페이파, 필터권지 및 접착제 특성이 제품담배 공기희석율에 미치는 영향)

  • 김정열;김종열;신창호
    • Journal of the Korean Society of Tobacco Science
    • /
    • 제24권1호
    • /
    • pp.60-66
    • /
    • 2002
  • The ventilation rate of a ventilated filter cigarette depends on the details of its construction and on the properties of its components such as tobacco column pressure drop, filter pressure drop, tipping paper and plug wrap permeability, and vent position. Also, It was affected by the condition of adhesion of glue between tipping paper and plug wrap. This study was carried out to find the effect of surface properties of tipping paper and plug wrap, and a characteristics of glue on the ventilation rate of cigarettes. Our results indicated that the surface properties of tipping paper and plug wrap affected on the ventilation rate of cigarette. Also, the variation of ventilation rate was affected by the surface properties of tipping paper and the size of glue particles. We also found that the surface properties of tipping paper and plug wrap, and the emersion size of glue were the major factors to concern in the design for materials of cigarettes.

On the Characteristics of the Flow with Opening and Shutting of Access Panels in a Clean Room (Access Panel 개폐에 따른 청정실내 유동특성)

  • Park, M.S.;Lee, Jae-Heon;Ahn, K.H.;Kim, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제5권1호
    • /
    • pp.55-64
    • /
    • 1993
  • A numerical investigation has been carried out for the two-dimensional flow and pressure characteristics in a clean room equipped with two kinds of filters and four access panels. The distributed pressure resistance concept was applied to describe the momentum loss in filters and access panels. As a result, the velocity profile in the clean room became rather smooth by the presence of access panels. Furthermore, the average pressure drop of each access panel reached the same value so that the ratio of the flow rate should be the same at any zone. The closing of an access panel with maintaining the other access panels being opened had influenced on the velocity distribution in lower two thirds of left half space of the clean room.

  • PDF

An Experimental Study on the Degradation of Polymer in Closed Flow System (밀폐계 유동시스템내에서 고분자물질의 퇴화에 관한 실험적 연구)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권5호
    • /
    • pp.679-686
    • /
    • 1999
  • This study is to investigate the effect of a substantial drag reduction caused by the polymer(A611P) when the working fluids flow to the vertical direction in the vertical cylindrical equipment of closed flow system. The drag reduction is associated with the mechanical degrada-tion thermal degradation and heat transfer. By ignore the heat fluxs within the closed system the pressure drop due to the polymer concentration the flow velocity and flow time have been mea-sured. By taking into account the mechanical and thermal degradation in the closed system an experiment has been focused on the determination of the condition which could improve the pump capacity in the heat union electric power plant. Under the condition of non-boiling it has been found out that the change of heat flux has little influence on the drag reduction.

  • PDF

Effects of the Temperature Glide and Superheat of R407C on the Performance of Evaporator (R407C의 온도구배와 과열도가 증발기 성능에 미치는 영향)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제15권10호
    • /
    • pp.852-859
    • /
    • 2003
  • R407C is considered as an alternative refrigerant of R22 for air conditioners. An experiment was carried out to investigate the characteristics of the evaporation heat transfer and pressure drop for refrigerant R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning unit. The experimental data were useful in analyze the effects of the temperature glide and superheat for R407C. Test were conducted at the conditions of inlet refrigerant evaporation temperature of 7$^{\circ}C$, inlet air relative humidity of 50%, and refrigerant mass fluxes varying from 150 to 250 kg/m$^2$s. Representative results show that the heat exchanger performance for R407C evaporation is significantly affected by the change of the flow pattern from two-phase to super-heated vapor flow.

Analysis of Flow Field in a Steam Turbine Bypass Valve (증기터빈 바이패스밸브 케이지 유동장 해석관한 연구)

  • Choi Ji-Yong;Cho An-Tai;Kim Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • 제9권4호
    • /
    • pp.36-42
    • /
    • 2006
  • In the present work, characteristics of the flow in the cage of a steam turbine bypass control valve for thermal power plant are investigated. Experimental measurement for wall static pressure has been carried out to validate numerical solutions. And, the flowfield is analyzed by solving steady three-dimensional Reynolds-averaged Navier-Stokes equations. Shear stress transport (SST) model is used as turbulence closure. The effects of the flow area between stages of the cage on the pressure drop are also found.

Electrochemical Parameters with unusual Alternating Current Phase-Angles

  • Rashwan Farouk;Mohran Hossnia
    • Journal of the Korean Electrochemical Society
    • /
    • 제7권2호
    • /
    • pp.80-82
    • /
    • 2004
  • The a.c. technique is employed to evaluate electrochemical characteristics of Naphthalie-1,4,5,8-tetracarboxylic acid bisanilide (NTB). The measurements were carried out in dry and pure propionitrle (PCN) and acetonitrile(CAN) at the hanging mercury drop electrode [HMDE). An A.C. phase sensitive detector using computer controlled lock-in amplifier was employed. Primary goal of this report, was to establish on a firm the rare behavior of the phase angle associated with a.c. polarograms of the compound. Although, not an initial goal of this study, the electron transfer rate parameters attending the electroreduction of the compound under investigation were determined. This because the results shed some light on the electrokinetics in aprotic solvent which until recently negligible data were available. Experimental Results and comparison of data obtained are reported. The good precision of the method makes it suitable for studying electrochemical data with unusual behavior at electrodes in non aqueous media.

A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop (발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구)

  • Kim, Hak-Man;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제63권4호
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

Analysis of the Methods to Decrease the Depth of Menu in Web Site (웹사이트 메뉴 Depth를 줄이는 방식간의 비교 분석)

  • Park, Hui-Seok;Kim, Yu-No
    • Journal of the Ergonomics Society of Korea
    • /
    • 제19권3호
    • /
    • pp.61-75
    • /
    • 2000
  • To enhance web site's usability, it has been suggested that the depth of tree structured menus should be minimized. In this research, experimental results are reported to quantitatively compare the methods currently used for reducing the depth of menus in web sites. 25 popular web sites were selected and their menu types were categorized into four types: top menu, drop-down menu, boolean menu, and table of contents. The four types of menu were then sub-categorized into 15 different types according to their sub-menu type, existence of menu colors, and the event occurring after mouse activation. Performance tests and subjective evaluation were carried out. The results showed that there were no significant differences in terms of response time among the 15 menu types, while table of contents and drop-down in which the first and second level of menus were visible induced the least number of errors. In the subjective test, the top-menu structure with colors and presentation of its sub-menu without clicking mouse were preferred.

  • PDF