• Title/Summary/Keyword: Drop Impact Test

Search Result 250, Processing Time 0.026 seconds

Experimental Study on Combined Failure Damage of Bi-directional Prestressed Concrete Panel under Impact-Fire Loading (충돌 후 화재에 대한 이방향 프리스트레스트 콘크리트 패널부재의 복합 파괴손상에 관한 실험적 연구)

  • Yi, Na-Hyun;Lee, Sang-Won;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.429-440
    • /
    • 2014
  • Since the World Trade Center and Pentagon attacks in 2001, terror, military attack, or man-made disaster caused impact, explosion, and fire accident have frequently occured on civil infrastructures. However, structural behavior researches on major Prestressed Concrete (PSC) infrastructures such as bridges, tunnels, Prestressed Concrete Containment Vessel (PCCVs), and LNG tanks under extreme loading are significantly lacking. Especially, researches on possible secondary fire scenarios after terror, bombing, collision of vehicles and vessels on concrete structures have not been performed domestically where most of the past researches related to extreme loadings on structures focused on an independent isolated extreme loading scenario. Due to the outcry of public concerns and anxiety of potential terrorist attacks on major infrastructures and structures, a study is urgently needed at this time. Therefore, in this study, the bi-directional prestressed concrete $1400{\times}1000{\times}300mm$ panels applied with 430 kN prestressing force using unbonded prestressing thread bars were experimentally evaluated under impact, fire, and impact-fire combined loadings. Due to test site restrictions, impact tests were performed with 14 kN impactor with drop heights of 10m and 3.5 m to evaluate impact resistance capacity. Also, fire and impact-fire combined loading were tested using RABT fire loading curve. The measured residual strength capacities of PSC and RC specimens applied with impact, fire, impact-fire combined loadings were compared with the residual strength capacity of undamaged PSC and RC specimens for evaluation. The study results can be used as basic research data for related research areas such as protective design and numerical simulation under extreme loading scenarios.

A Study of Joint Reliability According to Various Cu Contents between Electrolytic Ni and Electroless Ni Pad Finish (전해Ni, 무전해 Ni pad에서의 Cu 함량에 따른 접합 신뢰성에 관한 연구)

  • Lee, Hyun Kyu;Chun, Myung Ho;Chu, Yong Chul;Oh, Kum-Sool
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.3
    • /
    • pp.51-56
    • /
    • 2015
  • It has been used various pad finish materials to enhance the reliability of solder joint and recently Electroless Ni Electroless Pd Immersion Gold (the following : ENEPIG) pad has been used more than others. This study is about reliability according to being used in commercial Electrolytic Ni pad and ENEPIG pad, and was observed behavior of various Cu contents. After reflow, the inter-metallic compound (IMC) between solder and pad is composed of $Cu_6Sn_5$ (Ni substituted) by using EDS, and in case of ENEPIG, between IMC and Ni layer was observed the dark layer ($Ni_3P$ layer). Additional, it could be controlled the thickness of dark layer according to Cu contents. Investigated the different fracture mode between electrolytic Ni and ENEPIG pad after drop shock test, in case of soft Ni, accelerated stress propagated along the interface between $1^{st}$ IMC and $2^{nd}$ IMC, and in case of ENEPIG pad, accelerated stress propagated along the weaken surface such as dark layer. The unstable interface exists through IMC, pad material and solder bulk by the lattice mismatch, so that the thermal and physical stress due to the continuous exterior impact is transferred to the IMC interface. Therefore, it is strongly requested to control solder morphology, IMC shape and thickness to improve the solder reliability.

Analyses on Airbag Sensor Signals by Different Packaging (자동차용 에어백 센서의 패키징 방법에 따른 신호 전달 해석)

  • Kim, Yeong K.;Kang, Hyun Jin;Kim, Joon Ki
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.105-109
    • /
    • 2015
  • In this study, a new airbag sensor packaging technique of directly attachment by adhesive to the automobile frame is introduced. To assess the feasibility for the packaging, a test instrument was manufactured to examine the impact sensibility by drop tests. The conventional sensor module attached mechanically by bolts with plastic housing and the new sensor packaging were installed to aluminum channel, and the results were compared with each other. Numerical analysis was also performed to investigate the signal characteristics created by the sensors. The preliminary results showed that the pattern of the MEMS sensor signal was strongly dependent on the structural behavior of the frame where the sensors were installed, which indicated the complexity of the packaging design for proper airbag deployments.

Estimation of Structural Dynamic Properties Using Signal Processing Techniques (신호처리기법을 이용한 구조물의 동특성치 추정)

  • Tae-Young,Chung;Yang-Han,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.2
    • /
    • pp.87-95
    • /
    • 1990
  • Conventional methods to estimate natural frequencies and damping ratios of structures from measured response time series obtained during impact tests are reviewed. Maximum Entropy Method and Least Square Prony Method are introduced to alleviate the inherent limitation of the conventional methods. The performance of the methods are explored through computer simulation. As an example of application, they are applied to the time series obtained from an anchor drop-and-snup test of a container ship and the result is compared to that of conventional FFT method. As a result of the computer simulation, it is found that Maximum Entropy Method is very efficient to estimate natural frequencies of structures when two neighboring natural frequencies are close enough and short data records are only available, but it is not a reliable estimator for damping ratios. And it is also found that Least Square Prony Method is efficient to estimate the natural frequencies and damping ratios of highly damped structural system, but the estimation efficiency of damping ratios is significantly deteriorated in the presence of significant additive noise.

  • PDF

High Strength SA508 Gr.4N Ni-Cr-Mo Low Alloy Steels for Larger Pressure Vessels of the Advanced Nuclear Power Plant (차세대 원전 대형 압력용기용 고강도 SA508 Gr.4N Ni-Cr-Mo계 저합금강 개발)

  • Kim, Min-Chul;Park, Sang-Gyu;Lee, Ki-Hyoung;Lee, Bong-Sang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.100-106
    • /
    • 2014
  • There is a growing need to introduce advanced pressure vessel steels with higher strength and toughness for the optimizatiooCn of the design and construction of longer life and larger capacity nuclear power plants. SA508 Gr.4N Ni-Cr-Mo low alloy steels have superior strength and fracture toughness, compared to SA508 Gr.3 Mn-Mo-Ni low alloy steel. Therefore, the application of SA508 Gr.4N low alloy steel could be considered to satisfy the strength and toughness required in advanced nuclear power plants. The purpose of this study is to characterize the microstructure and mechanical properties of SA508 Gr.4N low alloy steels. 1 ton ingot of SA508 Gr.4N model alloy was fabricated by vacuum induction melting followed by forging, quenching, and tempering. The predominant microstructure of the SA508 Gr.4N model alloy is tempered martensite having small packet and fine Cr-rich carbides. The yield strength at room temperature was 540MPa, and it was decreased with an increase of test temperature while DSA phenomenon occurred at around $288^{\circ}C$. Overall transition property of SA508 Gr.4N model alloy was much better than SA508 Gr.3 low alloy steel. The index temperature, $T_{41J}$, of SA508 Gr.4N model alloy was $-132^{\circ}C$ in Charpy impact tests, and reference nil-ductility transition temperature, $RT_{NDT}$ of $-105^{\circ}C$ was obtained from drop weight tests. From the fracture toughness tests performed in accordance with the ASTM standard E1921 Master curve method, the reference temperature, $T_0$ was $-147^{\circ}C$, which was improved more than $60^{\circ}C$ compared to SA508 Gr.3 low alloy steels.

Two Cases of Repetitive Episodic Tension-type Headache Patients who were Constitutionally Typed as Soyangin and Taeeumin (반복 발작성 긴장성 두통을 호소하는 소양인(少陽人) 태음인(太陰人) 치험 2례)

  • Park, Byung-Joo;Shin, Hyun-Sang;Kang, Mi-Jeong;Lee, Ji-Won;Jang, Hyun-Su;Lee, Jun-Hee;Lee, Eui-Ju;Koh, Byeong-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.22 no.2
    • /
    • pp.123-134
    • /
    • 2010
  • 1. Objectives: This study reports two cases of repetitive episodic tension-type headache patients who were each constitutionally typed as the Taeeum type and the Soyang type and respectively treated with Yanggyeoksanhwa-tang and Galgeunhaegi-tang. 2. Methods: The patients' subjective and objective symptoms were observed daily, and the VAS scores for the main symptoms were recorded daily throughout hospitalization period. When deemed necessary, other assessment tools were engaged (Migraine-Specific Quality of Life questionnaire, Migraine Disablity Assessment questionnaire, Headache Impact Test-6, etc.). 3. Results: The Soyang Type patient's headache improved by the end of hospitalization, with a dramatic drop in the VAS score from VAS 10 to VAS 2. The Taeeum Type patient's headache also showed improvement, with an equally dramatic decrease in the VAS score from VAS 10 to VAS 2. 4. Conclusion: Although the two patients were experiencing the same symptoms of repetitive episodic tension-type headache, they were each given different medicinal interventions in accordance to their respective constitutional types. This series of cases is notable in that the two widely different medications (Yanggyeoksanhwa-tang and Galgeunhaegi-tang) were applied to specifically conforming pathologies (the Sogal symptomatology and the Ganyeol symptomatology, respectively) to produce equally dramatic improvements.

Development of Design System for EPS Cushioning Package of Monitor Using Axiomatic Design (공리적 설계를 이용한 모니터용 EPS 완충 포장 설계 시스템 개발)

  • Yi, Jeong-Wook;Ha, Dae-Yul;Lee, Sang-Woo;Lim, Jae-Moon;Park, Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1644-1652
    • /
    • 2003
  • The monitor product is packed by cushioning materials because the monitor can be broken during transportation. However, the addition of the cushioning material increased the volume of the product. Therefore, it is required that the usage of cushioning material be minimized. In practice, design engineers have followed the ad hoc design with experiences of predecessors. Automation of the design process is very important for the reduction of engineering cost, and can be achieved by an excellent design process and software development. According to Axiomatic design, a design flow is defined and a software system is developed for automated design. At first, a basic model is defined. A user can modify the model from menus and design is carried out according to the input from the user. Finite element models are automatically generated based on the design. A nonlinear finite element analysis program called LS/DYNA3D is linked for the impact analysis. The process of Design of Experiments using orthogonal array is installed to minimize the maximum acceleration in drop test. Therefore, a new design can be proposed by the system. The program is designed according to the Independence Axiom of Axiomatic design. FRs and DPs of the software system are defined and decomposed by zigzagging process. Independent modules can be generated by analysis of the full design matrix and each module is coded as class in Object Oriented Programming (OOP). Design results are discussed.

A Study on the Effects of Surface Patterns on Droplet Impingement Behaviors (액적 충돌 거동에 대한 표면 패턴의 영향에 관한 연구)

  • Jeon, Min Kyeong;Kim, Doo-In;Kang, Shinill;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.107-112
    • /
    • 2016
  • In this paper, the hydrophobic rough surfaces were prepared by employing a conventional nano-imprint lithography technique, and the effects of surface parameter, ratio of the top surface to the flat unit cell, on the impingement behaviors of liquid droplet were investigated to improve robustness of hydrophobic functionality. The critical height defined for the transition from rebound to fragmentation is measured by droplet impingement test in order to study dynamic behavior of an impinged droplet. It showed the critical height decreased with high surface parameter while it increased with low surface parameter. However, the critical height decreased again as surface parameter decreased further. Observed results suggest that the optimized surface pattern should be designed for the increased critical height.

Effects of Quercetin and Mannitol on Erythropoietin Levels in Rats Following Acute Severe Traumatic Brain Injury

  • Kalemci, Orhan;Aydin, Hasan Emre;Kizmazoglu, Ceren;Kaya, Ismail;Yilmaz, Hulya;Arda, Nuri M
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.3
    • /
    • pp.355-361
    • /
    • 2017
  • Objective : The aim of this study to investigate the normal values of erythropoietin (EPO) and neuroprotective effects of quercetin and mannitol on EPO and hematocrit levels after acute severe traumatic brain injury (TBI) in rat model. Methods : A weight-drop impact acceleration model of TBI was used on 40 male Wistar rats. The animals were divided into sham (group I), TBI (group II), TBI+quercetin (50 mg/kg intravenously) (group III), and TBI+mannitol (1 mg/kg intravenously) (group IV) groups. The malondialdehyde, glutathione peroxidase, catalase, EPO, and hematocrit levels were measured 1 and 4 hour after injury. Two-way repeated measures analysis of variance and Tukey's test were used for statistical analysis. Results : The malondialdehyde levels decreased significantly after administration of quercetin and mannitol compared with those in group II. Catalase and glutathione peroxidase levels increased significantly in groups III and IV. Serum EPO levels decreased significantly after mannitol but not after quercetin administration. Serum hematocrit levels did not change significantly after quercetin and mannitol administration 1 hour after trauma. However, mannitol administration decreased serum hematocrit levels significantly after 4 hour. Conclusion : This study suggests that quercetin may be a good alternative treatment for TBI, as it did not decrease the EPO levels.

Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study

  • De Oliveira, Greison Rabelo;Pozzer, Leandro;Cavalieri-Pereira, Lucas;De Moraes, Paulo Hemerson;Olate, Sergio;De Albergaria Barbosa, Jose Ricardo
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.217-223
    • /
    • 2012
  • Purpose: Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues. Methods: Twelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded, and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance. Results: The present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans, P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings. Conclusions: Zirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.