• 제목/요약/키워드: Drop Height

검색결과 419건 처리시간 0.026초

The competing roles of extensional viscosity and normal stress differences in complex flows of elastic liquids

  • Walters, K.;Tamaddon-Jahromi, H.R.;Webster, M.F.;Tome, M.F.;McKee, S.
    • Korea-Australia Rheology Journal
    • /
    • 제21권4호
    • /
    • pp.225-233
    • /
    • 2009
  • In various attempts to relate the behaviour of highly-elastic liquids in complex flows to their rheometrical behaviour, obvious candidates for study have been the variation of shear viscosity with shear rate, the two normal stress differences $N_1$ and $N_2$, especially $N_1$, and the extensional viscosity $\eta_E$. In this paper, we shall be mainly interested in 'constant-viscosity' Boger fluids, and, accordingly, we shall limit attention to $N_1$ and $\eta_E$. We shall concentrate on two important flows - axisymmetric contraction flow and "splashing" (particularly that which arises when a liquid drop falls onto the tree surface of the same liquid). Modern numerical techniques are employed to provide the theoretical predictions. It is shown that the two obvious manifestations of viscoelastic rheometrical behaviour can sometimes be opposing influences in determining flow characteristics. Specifically, in an axisymmetric contraction flow, high $\eta_E$ can retard the flow, whereas high $N_1$ can have the opposite effect. In the splashing experiment, high $\eta_E$ can certainly reduce the height of the so-called Worthington jet, thus confirming some early suggestions, but, again, other rheometrical influences can also have a role to play and the overall picture may not be as clear as it was once envisaged.

수평 공기 채널과 수직 물 채널로 구성된 플라스틱 필름/종이 가습 소자의 성능 (A Performance Analysis and Experiments on Plastic Film/Paper Humidifying Elements Consisting of Horizontal Air Channels and Vertical Water Channels)

  • 김내현
    • 대한기계학회논문집B
    • /
    • 제40권1호
    • /
    • pp.55-63
    • /
    • 2016
  • 본 연구에서는 기존 교차 적층 방식의 유리 섬유 재질 가습소자인 Glasdek의 성능을 능가할 수 있는 새로운 가습소재와 형상을 개발하였다. 개발된 가습소재는 셀룰로오스와 PET가 50%씩 배합된 재질이고 가습 면적을 증가시키기 위하여 절곡 깊이를 7 mm에서 5 mm로 감소시켰다. 이 경우 유발되는 과도한 차압손실을 줄이기 위하여 형상을 수평 채널 방식으로 변화시켰다. 동일 교차 적층 형상에서 셀룰로오스/PET 소자의 가습 효율은 유리섬유 소자의 효율보다 평균 26% 크다. 또한 동일 셀룰로오스/PET 재질에서는 평행 채널 소자의 가습 효율이 교차 적층 소자의 효율보다 평균 14% 크다. 압력손실의 경우는 동일 교차 적층 형상에서 유리섬유 소자의 압력손실이 셀룰로오스/PET 소자의 압력손실보다 2%에서 52% 크다. 또한 동일 셀룰로오스/PET 재질에서 평행 채널 소자의 압력손실이 교차 적층 소자의 압력손실보다 평균 14% 크다. 실험 데이터를 기존 상관식 또는 본 연구에서 개발된 해석 모델과 비교하였다.

펄스차이 폴라로그래피를 이용한 갑상선기능조절 약제 중의 2-mercapto-1-methyl-imidazole 분석 (Analysis of 2-Mercapro-1-Methylimidazole in Controlling Drug of Thyroid by Differential Pulse Polarography)

  • 김일광;천현자;한성수
    • 대한화학회지
    • /
    • 제48권2호
    • /
    • pp.137-143
    • /
    • 2004
  • 5.0${\times}10^{-2}$ M LiClO4 지지전해질에서 2-mercapto-1-methyl-imidazole(MMI)의 분석을 펄스차이폴라로그래피로 조사하였다. MMI의 분석에서 적절한 조건은 다음과 같다; 초기전위: -0.9 volts, 펄스세기: 0.08 mV, 주사속도: 2 mV/sec. 표준검량곡선은 1.0${\times}10^{-7}{\sim}8.0{\times}10^{-5}$ M 범위에서 좋은 직선성을 보였으며, 검출한계는 (2.2${\pm}0.1){\times}0.1^{-9}$ M이었다. 이 방법으로 첨가제의 방해없이 항갑상선 약제중의 MMI를 정량하는데 응용하였다.

사인 웨이브 휜-관 열교환기의 공기측 성능에 관한 실험연구 (An Experimental Investigation on the Airside Performance of Fin-and-Tube Heat Exchangers Having Sinusoidal Wave Fins)

  • 김내현;조진표;윤백
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.355-367
    • /
    • 2004
  • The heat transfer and friction characteristics of the heat exchangers having sinusoidal wave fins were experimentally investigated. Twenty-nine samples having different waffle heights (1.5 mm and 2.0 m), fin pitches (1.3mm to 1.7mm) and tube rows (one to three) were tested. Focus was given to the effect of the waffle configuration (herringbone or sinusoidal) on the heat transfer and friction characteristics. Results show that the sinusoidal wave geometry provides higher heat transfer coefficients and friction factors than the herringbone wave geometry, and the difference increases as the number of row increases. The i/f ratios of the herringbone wave geometry, however, are larger than those of the sinusoidal wave geometry. Compared to the herringbone wave geometry, the sinusoidal wave geometry yielded a weak row effect, which suggests a superior heat transfer performance at the fully developed flow region. Possible explanation is provided considering the flow characteristics in wavy channels. Within the present geometric range, the effect of the waffle height on the heat transfer coefficient was not prominent. The effect of the fin pitch was also negligible. Existing correlations highly overpredicted both the heat transfer coefficients and friction factors. A new correlation was developed using the present data.

3차원 모핑기법에 의한 18-24세 여성의 체형별 대표 형상 도출을 위한 연구 (Development of a Representative Model for Different Body Shapes of 18-24 Aged Women - An Application of a 3D Morphing Technique -)

  • 신주영;최영림;남윤자
    • 한국의류산업학회지
    • /
    • 제13권4호
    • /
    • pp.590-599
    • /
    • 2011
  • The purpose of this study is to classify body types into different groups based on 3D scanned data, and identify the representative body shapes that most frequently appear in the groups. A high frequency range was defined based on body measurement data, and representative shapes were identified based on body scan data of women aged 18-24. The major findings of this study are as follows. First, the three typical types of height, bust and drop mixes among Korean women aged 18-24 are as follows:) 155-88-N,) 160-82-A, and 165-85-A. Regarding the body type, the A and N types frequently appeared, while the H type was rare. Second, among the subjects of the high-frequency groups, upright bodies were selected as sample models and were used for morphing. An adjustment was made to the morphing results to reflect the body characteristics of the sample models evenly. Third, to verify the morphing results, the body sizes of the sample models and the created models were compared. The result showed that, the sizes were close to the average size of the sample models. Fourth, to verify whether the morphing processes adequately reflected the features of the body shapes, cross-section models of key body parts were made and the degree of representativeness was determined.

덕트내 요철의 단락위치 변화에 따른 열/물질전달 및 압력강하 특성 - 정렬 단락배열 요철 - (Heat/Mass Transfer and Friction Characteristic in a Square Duct with Various Discrete Ribs -In-Lined Gap Arrangement Ribs-)

  • 이세영;최청;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1640-1649
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements on heat/mass transfer in the cooling passage of gas turbine blades. A complex flow structure occurs in the cooling passage with rib turbulators which promote heat transfer on the wall. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. A numerical computation is performed using a commercial code to calculate the flow structures and experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. A square channel (50 mm $\times$ 50 mm) with rectangular ribs (4 mm $\times$ 5 mm) is used fur the stationary duct test. The experiments focus on the effects of rib arrangements and gap positions in the discrete ribs on the heat/mass transfer on the duct wall. The rib angle of attack is 60°and the rib-to-rib pitch is 32 mm, that is 8 times of the rib height. With the inclined rib angle of attack (60°), the parallel rib arrangements make a pair of counter rotating secondary flows in the cross section, but the cross rib arrangements make a single large secondary flow including a small secondary vortex. These secondary flow patterns affect significantly the heat/mass transfer on the ribbed wall. The heat/mass transfer in the parallel arrangements is 1.5 ∼2 times higher than that in the cross arrangements. However, the shifted rib arrangements change little the heat/mass transfer from the inline rib arrangements. The gap position in the discrete rib affects significantly the heat/mass transfer because a strong flow acceleration occurs locally through the gap.

장마전선 상에서 발생한 중규모 호우계 구조에 대한 연구 (Structure of Mesoscale Heavy Precipitation Systems Originated from the Changma Front)

  • 박창근;이태영
    • 대기
    • /
    • 제18권4호
    • /
    • pp.317-338
    • /
    • 2008
  • Analyses of observational data and numerical simulations were performed to understand the mechanism of MCSs (Mesoscale Convective Systems) occurred on 13-14 July 2004 over Jindo area of the Korean Peninsula. Observations indicated that synoptic environment was favorable for the occurrence of heavy rainfall. This heavy rainfall appeared to have been enhanced by convergence around the Changma front and synoptic scale lifting. From the analyses of storm environment using Haenam upper-air observation data, it was confirmed that strong convective instability was present around the Jindo area. Instability indices such as K-index, SSI-index showed favorable condition for strong convection. In addition, warm advection in the lower troposphere and cold advection in the middle troposphere were detected from wind profiler data. The size of storm, that produced heavy rainfall over Jindo area, was smaller than $50{\times}50km^2$ according to radar observation. The storm developed more than 10 km in height, but high reflectivity (rain rate 30 mm/hr) was limited under 6 km. It can be judged that convection cells, which form cloud clusters, occurred on the inflow area of the Changma front. In numerical simulation, high CAPE (Convective Available Potential Energy) was found in the southwest of the Korean Peninsula. However, heavy rainfall was restricted to the Jindo area with high CIN (Convective INhibition) and high CAPE. From the observations of vertical drop size distribution from MRR (Micro Rain Radar) and the analyses of numerically simulated hydrometeors such as graupel etc., it can be inferred that melted graupels enhanced collision and coalescence process of heavy precipitation systems.

BIOFILTRATION OF GASEOUS TOLUENE USING ADSORBENT CONTAINING POLYURETHANE FOAM MEDIA

  • Amarsanaa, Altangerel;Shin, Won-Sik;Choi, Jeong-Hak;Choi, Sang-June
    • Environmental Engineering Research
    • /
    • 제11권1호
    • /
    • pp.1-13
    • /
    • 2006
  • In this study, conventional biofilters packed with flexible synthetic polyurethane (PU) foam carriers were operated to remove toluene from a contaminated air stream. PU foams containing various adsorbents (e.g., zeolite, sepiolite, dolomite and barite) were synthesized for the biofilter media and their adsorption characteristics of toluene were determined. Adsorption capacity of PU-adsorbent foam was in the order of PU-dolomite ${\approx}$ PU-zeolite > PU-sepiolite > PU-barite. During the biofiltration experiment, influent toluene concentration was in the range of 0-160 ppm and EBRT (i.e., empty bed residence time) was 45 seconds. Pressure drop of the biofilter bed was 4-5 mm $H_2O/m$ column height. The maximum removal capacity was in the order of PU-dolomite > PU-zeolite > PU-sepiolite > PU-barite, while the complete removal capacity was in the order of PU-dolomite > PU-sepiolite > PU-zeolite > PU-barite. The better biofiltration performance in PU-dolomite foam was because PU-dolomite foam had lower density and higher porosity than the others providing favorable conditions for microbial growth. The results of biodegradation kinetic analysis showed that PU-dolomite foam had higher maximum removal rate ($V_m\;=\;11.04\;g$ toluene/kg dry material/day) and saturation constant ($K_s\;=\;26.57\;ppm$) than the other PU foams. This supports that PU-dolomite foam was better than the others for biofilteration of toluene.

항갑상선 의약물 중 2-mercapto-1-methyl-imidazole의 펄스차이 폴라로그래피에 의한 분석 (Determination of 2-Mercapto-1-methyl-imidazole in Antithyroid Drug by Differential Pulse Polarography)

  • 김일광;천현자;임순화
    • 분석과학
    • /
    • 제8권1호
    • /
    • pp.17-23
    • /
    • 1995
  • $5.0{\times}10^{-2}M$ $LiClO_4$ 용액 중에서 펄스차이 폴라그래피로 2-mercapto-1-methyl-imidazole(MMI)의 정량방법을 조사하였다. 분석의 최적 조건은 초기전위 -0.9 volt vs. Ag/AgCl, 펄스높이 80mV, 주사속도 2mV/sec, 중간 크기 수은방울이었다. 검정곡선은 $1.0{\times}10^{-7}M$에서 $8.0{\times}10^{-5}M$ 범위까지 좋은 직선성을 보여 주었으며, 검출한계는 $2.2{\times}10^{-9}M$이었다. 이 방법은 다른 첨가제의 방해 없이 항갑상선 치료제 중의 MMI 정량에 응용할 수 있었다.

  • PDF

골다공증에 따른 부위별 골 밀도와 구조의 변화 (Regional variation in vertebral bone density and structure due to osteoporosis)

  • 박정홍;이성재;장한;최우성;강철;탁계례
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.169-170
    • /
    • 1998
  • In this study, regional variation in vertebral bone density due to osteoporosis were investigated using a method that employs images from QCT. QCT images(1mm thick slices) of the first lumbar vertebra from a normal person (23/M, BMD=139.8mg/ml) and from an osteoporotic patient (54/F, BMD=82.0mg/ml) were obtained. Uniform settings (140kVp, 204mA) were used and images of 300 Hounsfield Unit or greater were selectied to filler out soft tissue interference. To assess the regional variation of the area fraction the vertebral body was divided into 3 layers and each layer contained 9 regions. Area faction was calculated based on image analysis data. Our results showed that the area fraction at the middle of the vertebra was quite lower than the endplate and peripheral regions, but the area fraction values from the osteoporotic patient were uniform throughout the entire height of the vertebral body, which indicates the significant drop of BMD had occurred near both end-plates due to the osteoporosis, especially at the peripheral regions. Our results suggest the susceptability of the vertebrae to compression fracture types in osteoporotic spine.

  • PDF