• 제목/요약/키워드: Driving pump design

검색결과 54건 처리시간 0.024초

Performance of a 2 Room Multi-Heat Pump with a Constant Speed Compressor

  • Kwan Young Chul;Kwon Jeong-Tae;Jeong Ji Hwan;Lee Sang Jae;Kim Dae Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.184-191
    • /
    • 2004
  • In order to improve the performance of a 2 room heat pump with a constant speed compressor, the optimum refrigeration circuit of the heat pump with different cooling and heating capacities is developed by applying capillary tubes. The refrigeration circuit is composed of four parts; a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The performance of the 2 room heat pump are investigated from a rating experiment and a reliability experiment, using the calorimeter. Results of the rating experiment show that the capacity of heat pump is about $93\%$ of the design value. In particular, the capacity of the cooling single operation is about $13\%$ higher than the design value, and the capacity of the heating multi operation is about $5\%$ higher than the design value. From the reliability experi-ment, it is found that the lowest driving voltage of the compressor is about $75\%$ of the rating voltage. Also the compressor is reoperated normally under the flood back and the over load.

넓은 출력 전압 범위를 갖는 위상동기루프를 위한 저전압 Charge Pump 회로 설계 (The Design of a Low Power and Wide Swing Charge Pump Circuit for Phase Locked Loop)

  • 부영건;고동현;김상우;박준성;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제45권8호
    • /
    • pp.44-47
    • /
    • 2008
  • 본 논문에서는 UWB PLL charge pump 의 충/방전 전류오차를 최소화하기 위한 회로를 제안하였다. Common-gate 와 Common-source 증폭기를 추가한 피드백 전압 조정기를 구성하여 높은 응답성을 가지는 charge pump를 설계하였다. 제안한 회로는 넓은 동작 영역을 갖으며, 낮은 전원 전압으로도 뛰어난 성능을 보인다. 본 회로는 1.2V 공급 전압과 IBM 0.13um CMOS 공정으로 집적되었다. 설계의 효율성을 평가하기 위해 참고 논문의 다른 회로와 성능을 대조하였다.

Driving Mechanism of Tapered Pistons in Bent-Axis Design Axial Piston Pumps

  • Kim, Jong-Ki;Jung, Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.181-186
    • /
    • 2003
  • In order to assure the quality of the bent axis design axial piston pumps driven by tapered pistons, it is necessary to know the characteristics of force applied to tapered pistons and the mechanism for driving the tapered pistons. Since they are able to perform both reciprocating and spinning motions in cylinder block, it is difficult to understand the driving mechanismand-tomeasure the forces applied to tapered pistons experimentally In the present study, the theoretical mechanism for driving the tapered pistons is studied by use of the geometric method. The driving area of the tapered pistons is measured by measuring the strain of a cylinder forced against a tapered piston using an electric strain gauge and a slip ring. The forces applied to tapered pistons is also investigated with the change of discharge pressure and the rotational speed. As a results of this investigation, it is concluded that the cylinder block is driven by one tapered piston in a limited area and the driving area is changed due to space angle of the tapered pistons and the swivel angle of the cylinder block. It is also observed that the force applied to tapered pistons increases as the discharge pressure and the rotational speed increase.

Design and Prototyping of a Novel Type Piezoelectric Micro-pump

  • Oh, Jin-Heon;Lim, Jong-Nam;Lee, Seung-Su;Heo, Jun;Lim, Kee-Joe
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.181-185
    • /
    • 2008
  • Using the extensional vibration mode of PZT ring, a piezopump is successfully made. The PZT ring is polarized with thickness direction. The traveling extensional wave along the circumference of the ring is obtained by dividing two standing waves which are temporally and spatially phase shifted by 90 degrees from each other. The proposed piezopump is consisted of coaxial cylindrical shells that are bonded piezoelectric ceramic ring. The pump takes an unobtrusive operation into the simple displacing mechanism using peristaltic traveling waves without the physical moving parts. The finite elements analysis on the proposed pump model is carried out to verify its operation principle and design by the commercial FEM software. Components of piezopump were made, assembled, and tested to validate the concepts of the proposed pump and confirm the simulation results. The performance of the proposed piezopump is about 580 ${\mu}l/min$ in flow rate with the highest pressure level of 0.85 kPa, when the driving voltage is 150 $V_p$, 57 kHz.

Hydraulic System Design and Vehicle Dynamic Modeling for the Development of a Tire Roller

  • Kim, Sang-Gyum;Kim, Jung-Ha;Lee, Woon-Sung
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권4호
    • /
    • pp.484-494
    • /
    • 2003
  • In this paper, we describe a hydraulic system design and vehicle dynamic modeling for development of tire roller traction, an essential aspect in the system analysis of tire rollers. Generally, tire rollers are one of the most useful types of machines employed in road construction, technically applied to many construction fields. We also conceptualize a new hydraulic and driving system as well as define the motion equations for dynamic and hydraulic analysis. First, we design the hydraulic circuit of the steering control and driving machine system, which can be employed to advance the performance of the lateral control, creating a prototype of construction equipment. Second, we formulate the hydraulic steering system model and hydraulic driving system model through tire roller system development technology. Finally, we validate the acquired performance results in actual tire roller equipment using the data acquisition system. These results may perhaps facilitate the establishment of priorities and design strategies for incremental introduction of tire roller technology into the vehicle and construction field.

특수 차량용 정용량 피스톤 펌프의 개발에 관한 연구 (The Study on Development of Fixed Displacement Piston Pump for Special Access Vehicle)

  • 박정호;김문경;최석창
    • 한국기계가공학회지
    • /
    • 제9권3호
    • /
    • pp.19-27
    • /
    • 2010
  • Cylinder block is driven by tapered piston for bent-axis type piston pump, so that geometrical mechanism is very complicate. Piston rod must have not separated from shaft when shaft and piston rod is assembled. For this reason, shaft design is changed. Finite element analysis is performed for analyzed structural stability and flexible dynamic behavior. The result of the analysis, maximum equivalent stress occurred under yield stress, therefore structural stability is satisfactory. and flexible dynamic analysis give useful information about driving gear. These background data is avail of manufacture of piston pump.

저온 폐열 회수를 위한 제1종 흡수식 열펌프의 컴퓨터 시뮬레이션 (Computer Simulation of an Absorption Heat Pump for Recovering Low Grade Waste Heat)

  • 강상우;강병하;정시영;이춘식
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.187-197
    • /
    • 1996
  • A computer program for thermal design analysis has been developed to predict the operating characteristics and performance of an absorption heat pump to recover $30{\sim}40^{\circ}C$ of waste hot water. The effects of heat transfer area of the system components, temperature and mass flow rate of heat transfer medium, and solution circulation rate on the system performance are investigated in detail. The results obtained indicate that the COP is increased with a decrease in the temperature of driving steam and with an increase in the temperature of waste hot water while the COP is little affected by the variation of a hot water temperature. It is also found that the heating output is increased with an increase in the temperature of waste hot water and driving steam as well as with a decrease in the temperature of hot water. The simulation results are also compared with the experimental results for a periodic operation of the system and obtained a satisfactory agreement.

  • PDF

디스크형 진동자의 연동 운동을 이용하는 밸브리스 마이크로 압전 펌프 (Valveless piezoelectric micro-pump exploiting two sided disk type vibrator)

  • 오진헌;임종남;정의환;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.159-159
    • /
    • 2009
  • Existence of physical moving parts (ex. check valve) produces several problems (mechanical abrasion, deterioration of reliability, limited temperature performances etc.) in driving pumps. To overcome such problems, we proposed a valveless piezoelectric micro-pump which has new type volume transferring mechanism. The proposed micro-pump has a double faced disk type vibrator that can generate peristaltic motion formed by traveling wave in each surface of a disk. This type of micro-pump is able to apply to a fluid supply system that provides two different kinds of fluid simultaneously. In this paper, we propose a simple and novel design of piezoelectric micro-pump that is peristaltically by piezoelectric actuators and allows the removal of the need for valves of other physically moving parts. The finite elements analysis on the proposed pump model was carried out to verify its operation principle using the commercial analysis software.

  • PDF

자동차 연료펌프 구동용 보이스 코일 전자기 엑츄에이터의 설계 및 해석 (Design and Analysis of Voice Coil Actuator to Drive Fuel Pump in Automobile)

  • 박세명;김진호;배철호
    • 한국자기학회지
    • /
    • 제20권6호
    • /
    • pp.234-238
    • /
    • 2010
  • 캠샤프트의 구동력을 활용한 기계식 연료펌프 시스템을 대체할 솔레노이드 격막 연료펌프는 최근 각광받고 있는 고효율 그린카 부품 중 하나이다. 하지만 솔레노이드 격막 연료펌프의 경우 왕복운동에 필요한 자속을 오직 솔레노이드에 의존하므로 전력소비가 비교적 큰 단점이 있다. 따라서 본 연구에서는 전력소모를 최소화 하기 위하여 영구자석형 VCA 연료펌프 시스템을 제안한다. 또한 상용전자기해석소프트웨어인 MAXWELL을 활용하여 유한요소 해석을 통해 기존의 솔레노이드 격막 펌프와의 전력소모 및 동적 성능을 비교 분석한다.

펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰 (Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump)

  • 허민웅;민지호
    • 한국압력기기공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.