• 제목/요약/키워드: Drive-assisting System

검색결과 3건 처리시간 0.02초

Analysis on Muscle Activities in the Upper Body of Caregivers according to Drive-Assisting Speeds of a Shower Carrier

  • Ko, Cheol Woong;Cho, Deok Yeon;Bae, Tae Soo
    • 대한인간공학회지
    • /
    • 제32권5호
    • /
    • pp.437-442
    • /
    • 2013
  • Objective: The objective of this study was to investigate the effects of drive-assisting system in a shower carrier on the upper body muscle activities of caregivers through drivability tests. Background: In care facilities, one of the major ADL (Activities of Daily Living) factors is bathing/showering. Recently, bath/shower-assisting equipment is actively being introduced in care facilities to reduce caregivers' muscle burden. In particular, it is desirable to utilize a shower carrier equipped with drive-assisting system to effectively care for the elderly. However, there were few systematic studies on the relationship between muscle activities and drive-assisting speeds. Method: For the drivability tests to study the effects on the muscle activities according to the drive-assisting speeds(corresponding drive-voltages: 0.0V, 2.0V, 2.1V, 2.3V), 6 females in their 40s($43{\pm}4yrs$, $157{\pm}5cm$, and $54.5{\pm}1.5kg$) were selected. To measure muscle activities of caregivers through drivability tests, 7 muscles in the upper body(TM/Trapezius Muscle, DM/Deltoid Muscle, BBM/Biceps Brachii Muscle, TBM/Triceps Brachii Muscle, ECRLM/Extensor Carpi Radialis Longus Muscle, FCUM/Flexor Carpi Ulnaris Muscle, and ESM/Erector Spinae Muscle) were selected. Results: In the TM, muscle activities were decreased as 21% compared to 0.0V, when drive-voltage 2.0V was applied, as 57% by 2.1V, and 62% by 2.3V(p<0.05), whereas 40%, 56%, and 69% of muscles activities were decreased respectively from the DM(p<0.05). Also, from the UL(BBM+TBM+ECRLM+FCUM), muscle activities were decreased by 17% with 2.0V as against 0.0V, by 47% with 2.1V, and 52% with 2.3V, whereas decreases in muscle activities from the ESM were found by 20%, 34%, and 42% respectively by 2.0V, 2.1V, and 2.3V(p<0.05). Conclusion: The muscle activities were decreased in the order of the DM, TM, ESM, and UL. As muscle activities were remarkably reduced as drive voltage were increased, it was expected to reduce the upper body muscle burden on the caregivers when using shower carriers equipped with driving-assist system. Applications: The results from this study can be applied for the development of a shower carrier including other equipment to possibly reduce the muscle burden of the caregivers.

장기 동물 실험 및 응급상황에서의 곡관형 좌심실보조장치의 생체적합성 평가 (Biocompatibility Evaluation of Bent-Type Left Ventricular Assist Device During Long-Term Animal Experiment and Emergent Situation)

  • 강성민;허균;최성욱
    • 대한기계학회논문집B
    • /
    • 제38권9호
    • /
    • pp.739-745
    • /
    • 2014
  • 심장 질환 환자에게 약물 치료를 시행하고 있으나, 통상의 약물 치료만으로는 심장질환을 치료하기에는 부족하다. 그러나 LVAD 를 이식한다면 심장기능을 보조하여 심장 이식까지의 가교 역할로서 효과가 있다고 보고되고 있다. 본 연구에서는 선행 연구로 개발된 곡관형 LVAD 인 LibraHeart-I(LH-1)을 이용하여, 대동물(Bovine model, Holstein)과 소동물(canine model, Labrador-retriever)을 대상으로 장기간 동물실험 및 응급상황에서의 생체적합성을 평가하고자 한다. 대동물을 대상으로 실시한 장기간의 동물 실험에서 49 일 생존하였으며, 실험기간 동안 실시한 혈액 검사 및 생징후에서 특이 소견을 관찰되지 않았다. 소동물을 대상으로 한 단기간의 동물 실험에서는 외부 구동부의 동력 지원 없이도 LH-I 내에 혈액이 머무르지 않는 것으로 관찰되었다. 본 연구에서는 장기간 동물실험 및 응급상황에서의 박출 성능을 통해 선행 연구로 개발된 LH-I의 생체적합성을 검증하였다.