• Title/Summary/Keyword: Drinking water source

Search Result 226, Processing Time 0.026 seconds

A Study on the Drinking Water Quality and Contamination Sources in a Rural Area (일부 농촌지역의 오염원 현황과 먹는 물 수질에 관한 조사연구)

  • 김탁수;이용미;김문선;김성연;신해철;최경호;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.98-103
    • /
    • 2004
  • To evaluate the quality of drinking water and contamination sources in a rural community, this study was carried out on the summer of 2003 at Shin-Dong Myun, Chun-Cheon, Gang-Won province. Seventy three drinking water samples were collected from three different types of water supply systems. Sources of contamination were identified and the public perception of water quality area were evaluated. The findings of this study are as follows; Drinking water was mainly obtained from Local Water and Simple Piped Water Supply Systems, and pollution sources varied over the study area. Most of residents (>63%) were satisfied with the quality of drinking water and could not identify any contamination sources. Corresponding to this perception, measured water quality parameters generally met the Drinking Water Quality Standards (>64%). However, approximately 35.6% of samples exceeded the regulation for Nㅒ$_3$$^{-}$$_{-}$N, coliform, and general bacteria. The water quality was significantly different among the three water supply systems, and between the potentially contaminated areas and the rest of the areas (p<0.05). In the potentially contaminated areas, the levels of coliform and general bacteria contamination were significantly higher than the rest of the areas (p<0.05). The coliform and general bacteria values of Simple Piped Water were significantly higher than Own Piped Water's, and the NO$_3$$^{-}$$_{-}$N values of Own Piped Water were significantly higher than those of water's (p<0.05). Based on this study, NO$_3$$^{-}$$_{-}$N, coliform, and general bacteria were identified as a major problem of drinking water. To regularly manage drinking water supply systems, to identify contamination sources, and to add drainage systems are required in the study area.

Reasonable Decision Making for Sustainable Water Supply Source Management (상수원의 지속가능한 관리를 위한 합리적 의사결정 방향)

  • Choi, Ji Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.504-511
    • /
    • 2007
  • Built-out issue of copper processing appearing recently in the Paldang watershed is a critical problem to deteriorate the basic framework of national water management policy as well as to be simply a copper-related problem. Up to now, Korea government has invested hard and relevant upstream areas have been victimized readily in a variety of field to comply its goal of 'Safe Water Supply'. Because of the reason, the desirable water quality level of the Paldang watershed has been maintained regardless of its dense population. Paldang drinking water management policy is based on residents' understanding which is considered as a 'social capital'. The issue raised in the aspect of water quality management policy should be reviewed on the basis of the 'social capital' concept. One regarding semiconductor industry as a potential industry to export many products in 10 years insists that the industry not be a simple private business but be a prominent part for national competitiveness. There is no doubt about this opinion. However, a nation should support environmental right-to-life of its people prior to any other tasks. In other words, it is really risky to give up people's right due to economic benefits. Therefore, it should not happen to trade 'life', the dignity of man, with national competitiveness which is likely to be preferred in these days. In addition, coherent policy not to destroy 'social capital' promoting Paldang drinking water resource management policy should be maintained.

Silver Contamination in Drinking Water of Gyeongbuk Area in Korea (경북 지역 먹는 물의 은 검출 특성)

  • Lee, Hea Geun;Kim, Jeong Jin;Kim, Young Hun
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.3
    • /
    • pp.233-242
    • /
    • 2020
  • As studies and developments of nano-material increase, the release of the nano-sized material to water environment increase. Especially, silver nanoparticles have been found as dissolved and particulate state since nano-silver particle have been intensively used in industrial and our living environment due to the anti-bacterial effect of the nano-particles. The silver nano-particles and silver ion gives adverse effect on ecology and US-EPA set a secondary drinking water standards as 0.1 mg/L. Current study focused on the analysis of silver in groundwater, small scale water supply systems in Gyeongbook area. The results have been compared with the secondary drinking water standards and discussed at the point of characteristics of the local area and purpose of use of the water sample. Among the total of 298 samples, 2 samples exceed the secondary drinking water standards of EPA, 0.64% rate. Community drinking water and simplified water service showed relatively high detection rate and groundwater gave relatively higher concentration of silver indicating anthropogenic source and natural source could contribute simultaneously on groundwater.

Removing Nitrate from Groundwater by Biofilm Filtration (생물막 여과에 의한 지하수중 질산성 질소의 제거)

  • Lee, Yong-Doo;Ko, In-Beom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.83-89
    • /
    • 1998
  • The drinking water supply in Cheju entirely depends on the ground water and recently the polluted ground water bores are increasing. In 1993 Cheju Province Health-Environment Institute reported that the ground water quality of 26 of 98 bores under the drinking water quality standard. Therefore there are many investigation in the needs of the nitrate removal in the drinking water in the regin with no alternative water resources. In this study, the following results are obtained to remove the nitrate in biofilm filtration process in which uses ethanol as external carbon source. Over 90% of nitrate is removed after 10 days of experiment. The nitrate removal rate on filtration velocity is about 100% at 50m/day and 100m/day, and about 56% at 200m/day. The removal rate is reduced in 27% at 400m/day. Using ethanol as the external carbon source, denitrification kinetic is 1st-order. Denitrification constant k is 8.004($hr^{-1}$). The amount of the denitrificated-Nitrogen is increased as the contact time increased. Deoxydation rate constant ${\gamma}$ is 11.895($hr^{-1}$). 0.968g of ethanol(as TOC) is needed to remove 1g of nitrate and 0.291g is required to remove 1g of dissolved oxygen.

  • PDF

A Study on the Management & Utilization of School Drinking Water (학교음용수 관리 및 이용실태)

  • Hong, Jung-Ha;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.87-104
    • /
    • 2000
  • The purpose of this study was to obtain the basic data as a improvement method through the fact-revealing concerning the drinking water management of school and utilization of student. The problems of the research are as follows: First, to investigate status of management of drinking water by area and school. Second, to investigate student's utilization of drinking water by area and school. 1,400 students was selected at 45 elementary and middle-high schools located in Kang-won province, and this study was constituted of two questionnaires(for school's questionnaire and student's questionnaire). The results was analyse through the frequency analysis, $x^2$-test on the basis of the above research problem by SPSS program. The findings of this research are as follows; 1) The Management of School Drinking Water First, the source of school drinking water was mostly piped water. Inspection of water quality has been fulfilled under four times a year, in the other hands, from the result inspection, the schools which was given inadequate determination was 22.2%. Second, reservoir cleaning and hygiene inspection failed far short of the regulations. Especially, reservoir cleaning was managed by exterior consignment industry not low-level officials. Third, school water drinking was the most supplied through the type of water purifier. Water purifier has been distributed to city-located and middle-high school highly, factually the water from water purifier was served with water cup. Fourth, the selection standard of water drinking manager showed slightly differently by school, accordingly there need to develope integrated system with the respective to its effective systematic management. Fifth, water cup was mostly treated by only water clear, which is to vindicate the problems concerning hygiene management. 2) Utilization of school student on Drinking Water First, Disbelief on drinking water of school student was very high. Especially, proportion of middle-high school student's disbelief of drinking water was higher than elementary school student, also girls higher than boys. Many of student have heard to don't drink water from around people. And there were showed meaningful differences by area and school. Second, It was showed many student recognize had to utilize water purifier, boiled water. However, they have still drunken the tap water or portable water from their home. Third, Many of student showed negative response with the respective to the management conditions of drinking water in classroom, There were showed meaningful differences by area and school. From the fact-revealing of water cup management, Students mostly answered to 'only water clear' and the answer of 'None use' or 'With personal cup' was higher. Fourth, In bad experience of Drinking Water, student mostly answered to 'occasionally' and there were showed meaningful differences by school. student's disease experience with school drinking water was few and there were showed meaningful differences by area and gender.

  • PDF

A Study on the Drinking Water Quality and Problem of Simple Piped Water Supply System in a Rural Area (일부 농촌지역 간이상수도의 운영실태와 수질에 관한 조사연구)

  • 김영규
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.39-51
    • /
    • 1992
  • This study was carried out for 1 year between 1990 and 1991. The interviewers visited 513 households to evaluate the perception of the residents using the Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 48 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are summarized as follows: 1) Approximately 44.0% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 8 sites and valley water in 40 sites. 3) Considering the type of distribution of the SPWS, there are 40 natural gravity systems and 8 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 73.9% of the SPWS facilities %'ere used more than ten years. 5) 47.4% of the SPWS facilities are neighbored with pollution source. 6) 42.4% of the maintenance crews were not committed to their job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 36.9% of the residents complaind that the amount of daily water supply is not adequate. 8) About 55.6% of the residents felt that the water quality is good for drinking water and therefore, But in contrast, the biochemical tests indicated that most of the SPWS met the drinking water quality standards. 9) Under the present water analysis system, The method of sampling and analysis are not effective, so that analysis system shoud be done by local health center.

  • PDF

Hazardous event analysis in drinking water production using aquifer storage transfer and recovery (대수층 저장·이동 및 회수에 의한 음용수 생산과정에서의 위해사건분석)

  • Lee, Sang-Il;Ji, Hyon-Wook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2015
  • Aquifer storage transfer and recovery (ASTR) is a type of managed aquifer recharge which entails injecting water into a storage well and recovering it from a different well. It has effects of natural purification when injected water passes through aquifer medium, and can be a good way of supplying water especially in a region with poor surface water quality. This study is about an on-going effort to introduce ASTR as a solution to source water problems in coastal areas. A pilot study is being conducted in the delta of the Nakdong River. A proactive management system is incorporated to ensure the water qulity in the process of drinking water process. The system is based on the Hazard Analysis and Critical Control Point (HACCP) which is a tool originated from the food industry in order to assess hazards and establish control systems for the safety of food product. In this paper, we analyze hazardous events which can occur in the entire water supply system using ASTR as a first step to the incorporation of HACCP to drinking water production process.

A Survey on the Sanitary Condition of Water Source and Toilet in Korean Rural Area. (-부농촌지역이 상하중 위생실태조사)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.4 no.1
    • /
    • pp.41-46
    • /
    • 1977
  • Main objectives of this survey were to find out general sanitary status of water source, draining status and toilet in Shindong Myun, Chungseong Gun. Interviewers of fourteen students visited 1,775 households in this Myun, filled the survey form and checked sanitary conditions of the areas from September 1 to November 30, 1974. Results are summarized as follows: 1. Draining state of pumps is better than that of wells and also the the quality of water sources are better in pumps than in wells. Wells and pumps of 54.1% were constructed more than five years ago. 2. About 66.7% use pump water, 10.5% well water and 8.3% simple piped drinking water system and average water consumption is 22.7l per day per capita. Private water system is 66.0% while public system 27.1%. 3. Water is used for drinking, washing body and cleaning at 53.8% while only for drinking at 7.4%. 4. Nearest pollution sources of drinking water are mainly toilets and stables, and average distances between them are less than ten meters. 5. Toilets of 78.3% are used only by one households and those of 12.9% by two. 6. Toilets of 10.9% are inside main building while those of 85.4% outside main building. 7. Toilet tanks are covered only at 6.3% households while not covered at 95.4%. The contents of tanks are removed about twice a month (40.2%), and 84.1% use them as fertilizer on their own farm and contents of 10.1% are removed by other people. 8. Excreta are utilized on the vegetable farm by 38.2% households, on the vegetable and barley farms by 19.7% and on the paddy fields by 8.2%.

  • PDF

The Delineation of Water-Pollutant Buffering Zone for Sustaining Better Drinking Water Quality Using a GIS (GIS를 이용한 상수원 보호를 위한 수변구역 지정에 관한 연구)

  • Kim, Kye-Hyun;Yoon, Ho-Seok;Kwon, Woo-Suk
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.239-248
    • /
    • 2000
  • The aggravating water quality from the expansion of industrialization along with increasing population lead to develop more intensive physical measures to secure better drinking water quality. This study was mainly initiated to establish a water-pollutant buffering zone for the upper stream basin of Paldang--the major source area of drinking water for the metropolitan Seoul and suburban areas with a population more than 13 million. Two different criteria were considered in determining the buffering distance from the edge of the streamflow : 1km-width buffer zone for the special protection area which has been strictly controlled by the conventional laws for the protection of drinking water supply, and 500m-width buffer zone for the rest of the area. To delineate the exact boundaries of the water-pollutant buffering zone, GIS database was created integrating topography, hydrography, cadastral, and other related layers. The newly designated water-pollutant buffering zone would contribute to improve the water quality in a long term along with the conservation of the wet land. More study, however, should be made within the water-pollutant buffering zone such as the detailed survey of the pollutants, vegetation, and ecosystem for more effective management of the buffering zone.

  • PDF

Analysis of Micropollutants Present in Raw Water Supplied for the Several Drinking Water Treatment Plants in Seoul (서울시 정수장 유입 원수내 미량유해물질의 조사)

  • Oh, Byung-Soo;Kim, Kyoung-Suk;Ju, Seul;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.245-250
    • /
    • 2004
  • This study investigated the micropollutants present in raw water supplied for the several drinking water treatment plants in Seoul. The target sample waters were collected from the several sites, such as Jayang (JY), Kuui (KI), Paldang (PD) and Kangbuk (KB) at the Han-River stream. The analytical method used in this study enable us to detect about 300 kinds of chemicals commonly found in surface water at ppt level by GC-ion trap MS. In this study, the consideration on the analytic results focused on the four hazardous organics, such as benzenes, phenols, phthalates and pesticides. The numbers of each detected micropollutant were 1~8 kinds for benzenes, 1~7 kinds for phenols, 5~7 kinds for phthalates and 1~9 kinds for pesticides. For the pesticides, the higher concentration was detected in the water samples collected from PD and KB adjacent to the farming area, and at June and July, which is the busy farming season. The total concentrations of each micropollutants detected at all the sites were significantly lower than those of drinking water regulation in Korea as well as other advanced countries. However, the frequently detected micropollutants requires the steady and precise monitoring for the effective management of drinking water source.