• Title/Summary/Keyword: Drinking water analysis

Search Result 488, Processing Time 0.031 seconds

Statistical Analysis of Chlorine Residual in Korean Drinking Water (국내정수장의 잔류염소농도에 대한 조사연구)

  • Sohn, Jinsik;Kang, Hyosoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.281-287
    • /
    • 2006
  • Maintaining adequate chlorine residual is crucial in water treatment facilities, Treatment technique, newly promulgated regulation, requires sufficient disinfection in order to control more resistant microorganisms such as Viruses and Giardia lamblia. Each water treatment plant should report various water qualities including chlorine residual and disinfection by-products, thus plenty of data has been generated. Even though statistical analysis using these data are forced to investigate the status and effect of water qualities in water facilities very few researches have been performed in korea. This study performed statistical analysis of chlorine residual during three years in Korean drinking water. The average chlorine residual concentrations were 0.701mg/L, 0.738mg/L, 0.763mg/L in 2002, 2003, 2004, respectively. Monthly variations of chlorine residual was not significant. ANOVA result showed that yearly variance of chlorine residual is different in only less than $5000m^3/day$ of water treatment capacity. The statistical analysis can help government to establish new regulation with scientific basis.

Study on the unification between KS I ISO standard and official test method enacted by Korean Ministry of Environment - drinking water and indoor air quality - (환경오염공정시험기준과 KS ISO규격의 일원화에 관한 연구 - 먹는 물 및 실내공기질 -)

  • Lee, Jeong-Il;Lee, Ju-Hee;Lee, Jeong-Hee;Lee, Jun-Hee;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyung;Choi, Sung-Hun
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.102-113
    • /
    • 2012
  • Our study researched on unification of KS I ISO standard harmonized with ISO and Official Test Method enacted by Korean Ministry of Environment-drinking water and indoor air quality. We reviewed KS methods related to drinking water and indoor air quality for about 23,000 KS methods. KS methods related environmental field are classified as KS I, total 635 methods and 583 KS I methods were harmonized with ISO. For Environmental Standard methods for drinking water, 100 methods were reviewed according to 232 KS methods related to ISO/ TC 147 "Water Quality". Environmental Standard methods for indoor air quality were reviewed according to 95 KS standard methods related to ISO/TC 146 "Air Quality". By reviews and comparison tests for unifiable ES for drinking water and indoor air quality with KS methods harmonized with ISO, it was evaluated that for 100 ES methods for drinking water, 23 ES methods were unification complete, 29 ES methods were unification possible, 12 ES methods were unification impossible, no corresponding methods were found in KS I ISO for 36 ES methods and for 17 ES methods for indoor air quality,1 ES methods were unification complete, 3 ES methods were unification possible, 3 ES methods were impossible, no corresponding methods were found in KS I ISO for 10 ES methods.

Study on Improvement of tap water drinking rate of Seoul city Tap water 'Arisu' through usage and recognition analysis (서울시 수돗물 '아리수' 사용현황과 인식 분석을 통한 수돗물 직접 음용률 제고 방안 연구)

  • Min, Sae-yan;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.16 no.9
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study is to raise the drinking rate of Arisu, the tap water in Seoul, and to propose new solution for continuous water quality management and raising awareness. The research scope was limited to point-of-use water treatment system, and based on the this contents I proceed this study how this will help to increase direct drinking rate of Arisu. Through research, Korea has provided users with the ability to filter contaminated tap water simply as water to be rinsed through water purification. Therefore, it was predicted that it would be difficult to improve tap water as drinking water. With this study, I expect that the strength of point-of-use system and the reliability of tap water quality will be raised and hope various product will be developed to improve the perception as drinking water and I also expect that this can be applied to whole country even further in the scope of Seoul city.

A study on performance analysis and merging techniques of sensors in water quality measurement (수질계측센서의 성능분석 및 센서 융합기술에 관한 연구)

  • Yang Keun-Ho;Yoo Byung-Kook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.3
    • /
    • pp.143-148
    • /
    • 2006
  • There are need to manage the water quality to supply an safety to consumer through pipe and reservoir the drinking water that produced in a clean water reservoir. However, a management of water quality and monitoring in reservoir have never been performed. Recently, the government has enforced standards of water quality. However, we have a inferior technology of water quality as compared with one in USA, Japan, Germany, etc. In case of water quality inspection and analysis equipments, sensor technology is very important to improve the water quality inspection and to develop the analysis equipments. In this paper, we analyze a law and a regulation for management of drinking water quality, and propose the measurement standards of drinking water quality in pH, conductivity, residual chloride, turbidity and water temperature. Then, we analyze electrode sensors that interference within pH, conductivity, residual chloride in interference experiment.

  • PDF

A Study on the Drinking Water Quality and Problem of Simple Piped Water Supply System in a Rural Area (일부 농촌지역 간이상수도의 운영실태와 수질에 관한 조사연구)

  • 김영규
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.39-51
    • /
    • 1992
  • This study was carried out for 1 year between 1990 and 1991. The interviewers visited 513 households to evaluate the perception of the residents using the Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 48 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are summarized as follows: 1) Approximately 44.0% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 8 sites and valley water in 40 sites. 3) Considering the type of distribution of the SPWS, there are 40 natural gravity systems and 8 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 73.9% of the SPWS facilities %'ere used more than ten years. 5) 47.4% of the SPWS facilities are neighbored with pollution source. 6) 42.4% of the maintenance crews were not committed to their job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 36.9% of the residents complaind that the amount of daily water supply is not adequate. 8) About 55.6% of the residents felt that the water quality is good for drinking water and therefore, But in contrast, the biochemical tests indicated that most of the SPWS met the drinking water quality standards. 9) Under the present water analysis system, The method of sampling and analysis are not effective, so that analysis system shoud be done by local health center.

  • PDF

The analysis of pharmaceuticals in drinking water by HPLC/ESI-MS/MS (HPLC/ESI-MS/MS에 의한 먹는물(정수) 중 의약물질의 분석)

  • Park, Mi-Sun;Kim, Byung-Joo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.457-464
    • /
    • 2010
  • The analytical method of four pharmaceuticals (virginiamycin, erythromycin, tylosin and cimetidine) in drinking water was developed. Effective simultaneous sample clean-up and extraction by solid-phase extraction (SPE) using HLB cartridge prior to LC/ESI-MS/MS analysis were performed. A linear correlation observed in the calibration curves for drinking water in the range of 0.01~2.0 ng/mL showed above $r^2$=0.995. Absolute recovery was in the range of 64.7~118.1% (except cimetidine (37.7~48.1%)). Limit of detection (LOD) and limit of quantitation (LOQ) in spiked drinking water matrix were in the range of 1.6~74.8 pg/mL and 5.5~249.7 pg/mL, respectively. The established method can be used to determine low pg/mL levels of pharmaceuticals in the drinking water.

The Research Trend and Social Perceptions Related with the Tap Water in South Korea (수돗물 이용에 대한 국내 연구동향과 사회적 인식)

  • Kim, Ji Yoon;Do, Yuno;Joo, Gea-Jae;Kim, Eunhee;Park, Eun-Young;Lee, Sang-Hyup;Baek, Myeong Su
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.208-214
    • /
    • 2016
  • We analyzed research trend and public perception related with tap water to identify major factors affecting low consumption of tap water. 805 research articles were collected for text mining analysis and 1,000 on-line questionnaires were surveyed to find social variables influencing tap water intake. Based on the word network analysis, research topics were divided into 4 major categories, 1) drinking water quality, 2) water fluoridation, 3) residual chlorine, and 4) micro-organism management. Compared with these major research topics, scientific studies of drinking behavior, or social perception were rather limited. 22.4% of total respondents used tap water as drinking water source, and only 1% drank tap water without further treatments (i.e. boiling, filtering). Experience of quality control report (B=0.392, p=0.046) and level of policy trust (B=1.002, p<0.0001) were influential factors on tap water drinking behavior. Age (B=0.020, p=0.002) and gender (B= - 1.843, p<0.0001) also showed significant difference. To increase the frequency of drinking the tap water by social members, the more scientific information of tap water quality and the water policy management should be clearly shared with social members.

Analysis of Haloacetic Acids in Drinking Water by Direct Derivatization and Headspace-SPME Technique with GC-MS (Handspace Solid Phase Microextraction 방법에 의한 HAAs 분석에 관한 연구)

  • Cho, Deok-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.638-648
    • /
    • 2004
  • In many drinking water treatment plants, chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of haloacetic acid (HAAs). In this study, headspace solid-phase microextraction (HS-SPME) was studied as a possible alternative to liquid-liquid extraction for the analysis of HAAs in drinking water. The method involves direct derivatization of the acids to their methyl esters without methyl tert-butyl ether (MTBE) extraction, followed by HS-SPME with a $2cm-50/30{\mu}m$ divinylbenzene/carboxen/polydimethylsiloxane fiber. The effects of experimental parameters such as selection of SPME fiber, the volume of sulphuric acid and methanol, derivatization temperature and time, the addition of salts, extraction temperature and time, and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The $2cm-50/30{\mu}m$-divinylbenzene/carboxen/polydimethylsiloxane fiber, sulphuric acid of 1ml, methanol of 3ml, derivatization temperature of $50^{\circ}C$ derivatization time of 2hrs, sodium chloride salt of 10g, extraction time of 30 minutes, extraction temperature of $20^{\circ}C$ and desorption time of 1 minute at $260^{\circ}C$ were selected as the optimal experimental conditions for the analysis of HAAs. The linearities ($r^2$), relative standard deviations (%RSD) and limits of detection (LOD) for HAAs were 0.9978~0.9991, 1.1~9.8% and $0.05{\sim}0.2{\mu}g/l$, respectively.

Abundances of Uranium and Radon in Groundwater of Taejeon Area (대전지역 지하수에 함유된 우라늄 및 라돈의 함량)

  • Han, Jeong-Hee;Park, Kye-Hun
    • Economic and Environmental Geology
    • /
    • v.29 no.5
    • /
    • pp.589-595
    • /
    • 1996
  • The concentration of radioactive elements was measured from the groundwater samples of Taejeon Area. U and Rn concentrations of very high level were detected from many places, especially around Yusung. These levels are much higher than the concentration standards for the drinking water proposed by the United States Environmental Protection Agency. However, in Korea, there are no standard levels for the radioactive elements in drinking water yet. We think that it is necessary to provide such standards as soon as possible, and that the determination of radioactive elements in groundwater should be included in the routine analysis items for the drinking water quality, because many people currently use such relatively high level radioactive groundwater as their drinking water, especially around Yusung area.

  • PDF

A Demonstrative Operation of A Membrane Filtration System in Siheung Water Treatment Plant (시흥정수장 막여과시설 시범운영)

  • 김한승;김충환;김학철;윤재경;안효원
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.07a
    • /
    • pp.57-68
    • /
    • 2004
  • A demonstrative operation of a membrane system with its caparity of 3,600m$^3$/d was carried out using reservoir water as raw water for the application of membrane filtration system to drinking water treatment. The operation was undertaken at a constant flux of 0.9 m$^3$/m$^2$/d for three months. Backwashing with NaClO of 3 ppm was allowed for 30 seconds every 20 minutes of filtration. Physical cleaning was introduced after 69 times of filtration/backwashing cycle with air-scrubbing and backwashing for 1 minute, and flushing for 2 minutes. In this study, water treatment performance was investigated compared with the existing rapid sand filtration process. The membrane system was operated with no significant problems during the test period. Higher water quality was obtained in the membrane filtration than in the rapid sand filtration in terms of particulate matters such as turbidity and microbes. Although the finished water of the membrane filtration contained slightly higher concentration in dissolved matters than that of the conventional one, it met the drinking water standard. The demonstrative operation showed that membrane filtration has a reliability in drinking water treatment. Researches should be needed on cost analysis through long-term operation and optimization of operation condition for further application.

  • PDF