• Title/Summary/Keyword: Drilling survey

Search Result 116, Processing Time 0.021 seconds

Detection of Subsurface Ancient Remains in Sooseong Dang Area, Buan Using Ground Penetration Radar Technique (지하투과레이다 기법을 이용한 부안 수성당 지역의 지하 유적 탐사)

  • Lee, Hyoun-Jae;Jeon, Hang-Tak;Yun, Sul-Min;Hamm, Se-Yeong
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.553-563
    • /
    • 2019
  • In order to survey archaeological sites, drilling and excavation are carried out at the final stage. However, at the preliminary stage, non-excavation geophysical prospection is used for assessing underground archaeological ruins. Among the geophysical prospecting techniques, Ground Penetration Radar (GPR) prospection has effectively been applied to historical sites due to its high resolution at shallow depths. In this study, the GPR prospection was conducted to find underground ruins near Suseong-Dang, the place of ancient rituals in Buan area, Korea. First, the GPR prospection was conducted at three sites (Site-1, 2, and 3), and subsequently, the GPR prospection was carried out at Site-3 in more detail. As a result of the prospection, the underground layered structure of the survey area consists of three layers, which are soil layer, weathered rock, and sound rock from the surface. And the GPR anomaly to the archaeological structure was clearly identified at around 100-cm depth showing est-west direction that is parallel to the long-axis array. This GPR anomaly of irregular geomorphological features and intermittent distribution may be related to the ritual remains found in Suseong Dang. The GPR prospection could be effectively used to detect archaeological sites or remains buried in the ground.

Structural-Health Evaluation for Core Zones of Fill Dams in Korea using Electrical Resistivity Survey and No Water Boring Method (전기비저항 탐사와 무수보링을 이용한 국내 필 댐 코어존의 건전성 평가)

  • Lee, Sangjong;Lim, Heuidae;Park, Dongsoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.21-35
    • /
    • 2015
  • Electrical resistivity survey (2D and 3D) were employed for detection of possible weak zone of core zones of three central core earth-rockfill dams in Korea. In the 2D results, the core zones is lower resistivity zone with less than $50{\sim}400ohm{\cdot}m$, and the basement is relatively higher resistivity zone with over $1,000ohm{\cdot}m$. In the 3D results, especially, the weak zone with under $100ohm{\cdot}m$ was detected spatial distribution area in the dam. We also drilled boreholes to collect soil samples of core zones of each dam. Water was not used during boring, because water for rotary wash boring could cause structural damages in earth dams. We found that the soil samples of core zones from all of the boreholes correspond to CL (USCS), but we also found that the fluidized or water-saturated soil samples were found in lower resistivity zones. Therefore, the electrical resistivity survey and drilling method without water are a quick and efficient method for structural-health evaluation which is detection of possible weak zones in earth core rockfill dams.

Shallow subsurface structure of the Vulcano-Lipari volcanic complex, Italy, constrained by helicopter-borne aeromagnetic surveys (고해상도 항공자력탐사를 이용한 Italia Vulcano-Lipari 화산 복합체의 천부 지하 구조)

  • Okuma, Shigeo;Nakatsuka, Tadashi;Komazawa, Masao;Sugihara, Mitsuhiko;Nakano, Shun;Furukawa, Ryuta;Supper, Robert
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.129-138
    • /
    • 2006
  • Helicopter-borne aeromagnetic surveys at two different times separated by three years were conducted to better understand the shallow subsurface structure of the Vulcano and Lipari volcanic complex, Aeolian Islands, southern Italy, and also to monitor the volcanic activity of the area. As there was no meaningful difference between the two magnetic datasets to imply an apparent change of the volcanic activity, the datasets were merged to produce an aeromagnetic map with wider coverage than was given by a single dataset. Apparent magnetisation intensity mapping was applied to terrain-corrected magnetic anomalies, and showed local magnetisation highs in and around Fossa Cone, suggesting heterogeneity of the cone. Magnetic modelling was conducted for three of those magnetisation highs. Each model implied the presence of concealed volcanic products overlain by pyroclastic rocks from the Fossa crater. The model for the Fossa crater area suggests a buried trachytic lava flow on the southern edge of the present crater. The magnetic model at Forgia Vecchia suggests that phreatic cones can be interpreted as resulting from a concealed eruptive centre, with thick latitic lavas that fill up Fossa Caldera. However, the distribution of lavas seems to be limited to a smaller area than was expected from drilling results. This can be explained partly by alteration of the lavas by intense hydrothermal activity, as seen at geothermal areas close to Porto Levante. The magnetic model at the north-eastern Fossa Cone implies that thick lavas accumulated as another eruption centre in the early stage of the activity of Fossa. Recent geoelectric surveys showed high-resistivity zones in the areas of the last two magnetic models.

Development of Riverbank Filtration Water Supply and Return System for Sustainable Green House Heating and Cooling (지속가능 온실 냉난방을 위한 강변여과수 취수 및 회수시스템 개발)

  • Cho, Yong;Kim, Dae-Geun;Kim, Hyoung-Soo;Moon, Jong-Pil
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.20-29
    • /
    • 2012
  • The green house on the waterfront is air-conditioned by a water-source heat pump system with riverbank filtration water. In order to supply riverbank filtration water in alluvium aquifer, the riverbank filtration facility for water intake and recharge, two pumping wells and one recharge well, has been constructed. The research site in Jinju, Korea was chosen as a good site for riverbank filtration water supply by the surface geological survey, electrical resistivity soundings, and borehole surveys. In the results of two boreholes drilling at the site, it was revealed that the groundwater table is about 3 m under the ground, and that the sandy gravel aquifer layer in the thickness of 6.5 m and 3.5 m occurs at 5 m and 7 m in depth below the ground level respectively. To prevent the recharge water from affecting the pumped water which might be used as heat source or sink, the distance between pumping and recharge wells is designed at least 70 m with a quarter of recharged flow rate. It is predicted that the transfer term, the recharge water affects the pumping well, is over 6 months of heating season. Hydrogeological simulation and underground water temperature measurement have been carried out for the pumping and recharge well positions in order to confirm the capability of sustainable green house heating and cooling.

Application of Geographic Information System for Synthetic Analysis of Multidisciplinary Data in Seawater Intrusion Assessment (해수침투 조사자료의 통합적 해석을 위한 GIS의 적용)

  • Choi Sun-Young;Hwang Seho;Park Kwon Gyu;Shin Je-Hyun;Yoon Wang-Jung
    • Spatial Information Research
    • /
    • v.12 no.3
    • /
    • pp.275-283
    • /
    • 2004
  • In order to effectively, and accurately assess seawater intrusion in coastal area, multidisciplinary data including geophysical, well logging, and hydrogeochemical data should be managed in systematical way. Such systematical management of data is critical key to improve the re-usability of the data as well as the accuracy of the assessment by means of providing a method of synthetic analysis. Therefore, for systematical management of multidisciplinary data in seawater intrusion problem, we have developed a database management system and 3-D visualization interface based on geographic information system in this, study. All geophysical survey, well logging, hydrochemical, as well as drilling, data are classified as attribute data using Microsoft Access, and joined with spatial information based on ArcView. The database management system and 3-D visualization interface to handle these data, also, developed using the script language of ArcView. We think the development of database and 3-D visualization system will improve the efficiency of data management, user-friendliness of data access, and accuracy of data analysis.

  • PDF

Assessment of dentists' subjective satisfaction with a newly developed device for maxillary sinus membrane elevation by the crestal approach

  • Kim, Young-Kyun;Cho, Yong-Seok;Yun, Pil-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.6
    • /
    • pp.308-314
    • /
    • 2013
  • Purpose: The purposes of this study were to assess the dentists' subjective satisfaction with the crestal approach sinus (CAS) kit, a device for maxillary sinus membrane elevation by the crestal approach using a special drilling system and hydraulic pressure, and to summarize the subjective satisfaction of dental implants placed after a sinus lift procedure with the CAS kit. Methods: Thirty dental clinicians who had experience with dental implant placement after a sinus lift procedure with the CAS kit from June 2010 to May 2012 were included in this study. The questionnaire for the evaluation of the dentists' subjective satisfaction with the CAS kit was sent to the respondents and returned. The questionnaire was composed of two main parts. The first part was related to the sinus membrane perforation rate. The second part was related to the dentists' subjective satisfaction with the CAS kit. Results: A total of 28 dentists answered the questionnaire. Among 924 implant cases, sinus membrane perforation occurred in 38 cases (4.1%). Among the 28 dentists, 26 dentists (92.9%) were satisfied or very satisfied with the CAS kit. In particular, 24 dentists (85.7%) reported that safety, cutting performance, and user-friendliness of the CAS drill were advantages of the CAS kit. However, 7 dentists (25%) did not routinely use the hydraulic lifter for sinus membrane elevation. Conclusions: From the survey, it was shown that the respondents were generally satisfied with the CAS kit and that the cutting performance and safety of the drill component were considered strengths of the CAS kit.

Field Application of 3D seismic travel-time tomography (3차원 탄성파 지대공 토모그래피 현장 적용)

  • Moon, Yun-Seop;Ha, Hee-Sang;Lim, Harry;Ko, Kwang-Beom
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.233-237
    • /
    • 2006
  • 3D travel time tomography was conducted to characterize the subsuface structure in the valley area. In this study, an area($200m{\times}200m$), where borehole informations were available to aid in the interpretation, was covered with wide source/receiver coverage. In data acquisition, both hole to hole and reverse VSP array was employed. For the inversion, 3D seismic traveltime tomography algorithm based on Fresnel volume was implemented. When compared 3D velocity cube with the geological survey and drilling logs, both results were matched well. From this, we concluded that 3D seismic travel time tomography has enough potential to the field application.

  • PDF

Site Investigation of Abandoned Coal Mine and Stability of Road Tunnel (도로터널공사구간의 폐갱도 정밀조사 및 터널의 안정성 평가)

  • Shin, Hee-Soon;Kim, Jung-Yul;Lee, Byung-Joo;Han, Kong-Chang;Sunwoo, Choon;Song, Won-Kyung;Synn, Joong-Ho;Kim, Yoo-Sung;Park, Chan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.17-24
    • /
    • 2001
  • Several underground cavities were found during construction of a road tunnel in 600m length . The area belong to Whasoon coalfield where extensive ground subsidences have occurred. It is necessary to find other underground cavities which might be located just near the road tunnel for safety, The field surveys and laboratory tests were conducted such as surface geological survey(672m), surface reflection seismic exploration(399m), drilling test(3 NX holes), 9 laboratory tests for rocks, 3 boreholes televiewer tests, reflection seismic exploration in tunnel(2, 342m). To estimate the effects of underground cavities on the road tunnel, 3 geological section were analysed with FLAC-2D modeling. The effects of the ground reinforcement were also analysed.

  • PDF

3D Modeling For Resources Estimation of Ilmenite Deposits in Jikjeon-Ri, Hadong Korea (하동군 북천면 직전리에서 산출되는 티탄철석광상의 자원량 평가를 위한 광체 3D 모델링)

  • Kwak, Ji Young;Choi, Jin Beom;Cho, Hyen Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.285-297
    • /
    • 2013
  • Ilmenite deposits are developed along the Precambrian intercumulated anorthosite body in Jikjeon-Ri, Bukcheon-Myeon, Hadong, Korea. Both detailed geological survey and drilling prospecting data for seven boreholes can be used to do resource estimation with GOCAD S/W. 3D modeling using geostatistics is applied to predict the shape and size of Ti ore bodies. As a result, 5 Ti ore veins occurred along N-S direction and average grade of Ti and ilmenite resources are calculated as 2.98 wt% Ti and 7,494,303 metric tons ilmenite ore reserves (Ti 223,330 t). This 3D modeling will be applied to the whole ilmenite deposits in Hadong-Sancheong area to predict the exact distribution and resources estimations of Ti ores.

Studies on the Geological Environment of the Nanjido Waste Disposal Site: Gravity and Magnetic Investigations (난지도 매립지 및 그 주변의 지질환경 연구: 중력 및 자력탐사)

  • Kwon, Byung-Doo;Kim, Cha-Seop;Chung, Ho-Joon;Oh, Seok-Hoon
    • Economic and Environmental Geology
    • /
    • v.28 no.5
    • /
    • pp.469-480
    • /
    • 1995
  • Gravity and magnetic surveys were carried out to investigate the three-dimensional configuration and characteristics of the landfills at Nanjido waste disposal site. For terrain correction and three-dimensional density inversion of gravity data an algorithm, which calculates the gravity effect of a three-dimensional body by using the solid angle method, is developed. This algorithm has been proved to give more accurate terrain correction values for the small survey area having varied topography like Nanjido site as compared with widely used methods such as Hammer's method and multiquadric equation method. Density inversion of gravity anomaly data gives very useful information about the lateral and vertical variation of the landfills, which can be used to discriminate the kinds of wastes. The average density of filled materials appears to be $1.7\;g/cm^3$ which is much higher than the value $(0.8\;g/cm^3)$ estimated by Seoul City. The lateral variation of density shows high correlation with the pattern of ongoing depression of the landfills. The northern region of the landfill no. 1, which shows low density and high depression, is closely associated with the industrial waste and sludge filled area. The magnetic anomaly data provide information about relative concentration of magnetic materials, which is also very useful to investigate characteristics of the fills. Several high positive anomaly regions on the reduced-to-pole magnetic anomaly map are appeared to be associated with the industrial waste fills, but certain industrial waste fills show low negative anomalies. This kind of magnetic information can be used in selecting drilling locations over landfills away from buried metal products during the stabilization process.

  • PDF